Export Ready — 

Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles

Bibliographic Details
Main Author: Santos, Flávia Camilo Unterman [UNESP]
Publication Date: 2016
Other Authors: Paim, Leonardo Lataro [UNESP], Luiz Da Silva, José [UNESP], Stradiotto, Nelson Ramos [UNESP]
Format: Article
Language: eng
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.1016/j.fuel.2015.09.046
http://hdl.handle.net/11449/172113
Summary: This work presents the analytical method development for total reducing sugars determination in residual water samples obtained from sugarcane processing for ethanol production. This method was developed using pulsed amperometry with a glassy carbon electrode modified with graphene oxide containing copper nanoparticles. With pulsed amperometry detection was achieved a limit of detection of 6.4 × 10-6 mol L-1. The amperometric sensitivity was 1.6 × 10-2 A mol-1 L. The recovery study showed that the method has good accuracy and repeatability, with recovery of 92.8 ± 0.5%. Experiment results obtained showed that the sensor has good long-term stability, sensitivity and is interference free, and the method developed is simple and fast.
id UNSP_ee6e948d5b4bbbc443caf12eb8ecc76c
oai_identifier_str oai:repositorio.unesp.br:11449/172113
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticlesBioethanol productionCopper nanoparticlesGraphene oxidePulsed amperometryReducing sugarThis work presents the analytical method development for total reducing sugars determination in residual water samples obtained from sugarcane processing for ethanol production. This method was developed using pulsed amperometry with a glassy carbon electrode modified with graphene oxide containing copper nanoparticles. With pulsed amperometry detection was achieved a limit of detection of 6.4 × 10-6 mol L-1. The amperometric sensitivity was 1.6 × 10-2 A mol-1 L. The recovery study showed that the method has good accuracy and repeatability, with recovery of 92.8 ± 0.5%. Experiment results obtained showed that the sensor has good long-term stability, sensitivity and is interference free, and the method developed is simple and fast.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Institute of Chemistry, UNESP - Univ Estadual Paulista, Campus Araraquara, Department of Analytical Chemistry, Prof. Francisco Degni Street 55Campus de Rosana, UNESP - Univ Estadual Paulista, CCEE - Energy Engineering, Barrageiros Avenue 1881Institute of Chemistry, UNESP - Univ Estadual Paulista, Campus Araraquara, Department of Analytical Chemistry, Prof. Francisco Degni Street 55Campus de Rosana, UNESP - Univ Estadual Paulista, CCEE - Energy Engineering, Barrageiros Avenue 1881FAPESP: 2013/22846-9Universidade Estadual Paulista (Unesp)Santos, Flávia Camilo Unterman [UNESP]Paim, Leonardo Lataro [UNESP]Luiz Da Silva, José [UNESP]Stradiotto, Nelson Ramos [UNESP]2018-12-11T16:58:43Z2018-12-11T16:58:43Z2016-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article112-121application/pdfhttp://dx.doi.org/10.1016/j.fuel.2015.09.046Fuel, v. 163, p. 112-121.0016-2361http://hdl.handle.net/11449/17211310.1016/j.fuel.2015.09.0462-s2.0-849433118132-s2.0-84943311813.pdf43283096129419870072173018005712Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengFuel1,891info:eu-repo/semantics/openAccess2025-05-28T05:24:05Zoai:repositorio.unesp.br:11449/172113Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-05-28T05:24:05Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
title Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
spellingShingle Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
Santos, Flávia Camilo Unterman [UNESP]
Bioethanol production
Copper nanoparticles
Graphene oxide
Pulsed amperometry
Reducing sugar
title_short Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
title_full Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
title_fullStr Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
title_full_unstemmed Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
title_sort Electrochemical determination of total reducing sugars from bioethanol production using glassy carbon electrode modified with graphene oxide containing copper nanoparticles
author Santos, Flávia Camilo Unterman [UNESP]
author_facet Santos, Flávia Camilo Unterman [UNESP]
Paim, Leonardo Lataro [UNESP]
Luiz Da Silva, José [UNESP]
Stradiotto, Nelson Ramos [UNESP]
author_role author
author2 Paim, Leonardo Lataro [UNESP]
Luiz Da Silva, José [UNESP]
Stradiotto, Nelson Ramos [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Santos, Flávia Camilo Unterman [UNESP]
Paim, Leonardo Lataro [UNESP]
Luiz Da Silva, José [UNESP]
Stradiotto, Nelson Ramos [UNESP]
dc.subject.por.fl_str_mv Bioethanol production
Copper nanoparticles
Graphene oxide
Pulsed amperometry
Reducing sugar
topic Bioethanol production
Copper nanoparticles
Graphene oxide
Pulsed amperometry
Reducing sugar
description This work presents the analytical method development for total reducing sugars determination in residual water samples obtained from sugarcane processing for ethanol production. This method was developed using pulsed amperometry with a glassy carbon electrode modified with graphene oxide containing copper nanoparticles. With pulsed amperometry detection was achieved a limit of detection of 6.4 × 10-6 mol L-1. The amperometric sensitivity was 1.6 × 10-2 A mol-1 L. The recovery study showed that the method has good accuracy and repeatability, with recovery of 92.8 ± 0.5%. Experiment results obtained showed that the sensor has good long-term stability, sensitivity and is interference free, and the method developed is simple and fast.
publishDate 2016
dc.date.none.fl_str_mv 2016-01-01
2018-12-11T16:58:43Z
2018-12-11T16:58:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.fuel.2015.09.046
Fuel, v. 163, p. 112-121.
0016-2361
http://hdl.handle.net/11449/172113
10.1016/j.fuel.2015.09.046
2-s2.0-84943311813
2-s2.0-84943311813.pdf
4328309612941987
0072173018005712
url http://dx.doi.org/10.1016/j.fuel.2015.09.046
http://hdl.handle.net/11449/172113
identifier_str_mv Fuel, v. 163, p. 112-121.
0016-2361
10.1016/j.fuel.2015.09.046
2-s2.0-84943311813
2-s2.0-84943311813.pdf
4328309612941987
0072173018005712
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Fuel
1,891
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 112-121
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834482521736216576