Summary: | The present study reports the development and application of a flow injection analysis (FIA) system for the simultaneous determination of uric acid (UA) and caffeine (CAF) using cathodically pretreated boron-doped diamond electrode (CPT-BDD) and multiple-pulse amperometry (MPA). The electrochemical profiles of UA and CAF were analyzed via cyclic voltammetry in the potential range of 0.20–1.7 V using 0.10 mol L−1 H2SO4 solution as supporting electrolyte. Under optimized conditions, two oxidation peaks at potentials of 0.80 V (UA) and 1.4 V (CAF) were observed; the application of these potentials using multiple-pulse amperometry yielded concentration linear ranges of 5.0 × 10−8–2.2 × 10−5 mol L−1 (UA) and 5.0 × 10−8–1.9 × 10−5 mol L−1 (CAF) and limits of detection of 1.1 × 10−8 and 1.3 × 10−8 mol L−1 for UA and CAF, respectively. The proposed method exhibited good repeatability and stability, and no interference was detected in the electrochemical signals of UA and CAF in the presence of glucose, NaCl, KH2PO4, CaCl2, urea, Pb, Ni, and Cd. The application of the FIA-MPA method for the analysis of environmental samples resulted in recovery rates ranging between 98 and 104%. The results obtained showed that the BDD sensor exhibited a good analytical performance when applied for CAF and UA determination, especially when compared to other sensors reported in the literature. |
id |
UNSP_9eb8ab93e26ed723b1a42a0714e9d732 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/300362 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse AmperometryBDDcaffeineFIA systempulsed amperometrysimultaneous determinationuric acidThe present study reports the development and application of a flow injection analysis (FIA) system for the simultaneous determination of uric acid (UA) and caffeine (CAF) using cathodically pretreated boron-doped diamond electrode (CPT-BDD) and multiple-pulse amperometry (MPA). The electrochemical profiles of UA and CAF were analyzed via cyclic voltammetry in the potential range of 0.20–1.7 V using 0.10 mol L−1 H2SO4 solution as supporting electrolyte. Under optimized conditions, two oxidation peaks at potentials of 0.80 V (UA) and 1.4 V (CAF) were observed; the application of these potentials using multiple-pulse amperometry yielded concentration linear ranges of 5.0 × 10−8–2.2 × 10−5 mol L−1 (UA) and 5.0 × 10−8–1.9 × 10−5 mol L−1 (CAF) and limits of detection of 1.1 × 10−8 and 1.3 × 10−8 mol L−1 for UA and CAF, respectively. The proposed method exhibited good repeatability and stability, and no interference was detected in the electrochemical signals of UA and CAF in the presence of glucose, NaCl, KH2PO4, CaCl2, urea, Pb, Ni, and Cd. The application of the FIA-MPA method for the analysis of environmental samples resulted in recovery rates ranging between 98 and 104%. The results obtained showed that the BDD sensor exhibited a good analytical performance when applied for CAF and UA determination, especially when compared to other sensors reported in the literature.Institute of Chemistry São Paulo State University (UNESP), SPNational Institute for Alternative Technologies of Detection Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), SPDepartment of Chemistry Federal University of São Carlos (UFSCar), SPInstitute of Chemistry São Paulo State University (UNESP), SPUniversidade Estadual Paulista (UNESP)Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM)Universidade Federal de São Carlos (UFSCar)Wong, Ademar [UNESP]Santos, Anderson M.Feitosa, Maria H. A.Fatibello-Filho, OrlandoMoraes, Fernando C.Sotomayor, Maria D. P. T. [UNESP]2025-04-29T18:49:25Z2023-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.3390/bios13070690Biosensors, v. 13, n. 7, 2023.2079-6374https://hdl.handle.net/11449/30036210.3390/bios130706902-s2.0-85166286538Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBiosensorsinfo:eu-repo/semantics/openAccess2025-05-28T08:10:08Zoai:repositorio.unesp.br:11449/300362Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-05-28T08:10:08Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
title |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
spellingShingle |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry Wong, Ademar [UNESP] BDD caffeine FIA system pulsed amperometry simultaneous determination uric acid |
title_short |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
title_full |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
title_fullStr |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
title_full_unstemmed |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
title_sort |
Simultaneous Determination of Uric Acid and Caffeine by Flow Injection Using Multiple-Pulse Amperometry |
author |
Wong, Ademar [UNESP] |
author_facet |
Wong, Ademar [UNESP] Santos, Anderson M. Feitosa, Maria H. A. Fatibello-Filho, Orlando Moraes, Fernando C. Sotomayor, Maria D. P. T. [UNESP] |
author_role |
author |
author2 |
Santos, Anderson M. Feitosa, Maria H. A. Fatibello-Filho, Orlando Moraes, Fernando C. Sotomayor, Maria D. P. T. [UNESP] |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) Universidade Federal de São Carlos (UFSCar) |
dc.contributor.author.fl_str_mv |
Wong, Ademar [UNESP] Santos, Anderson M. Feitosa, Maria H. A. Fatibello-Filho, Orlando Moraes, Fernando C. Sotomayor, Maria D. P. T. [UNESP] |
dc.subject.por.fl_str_mv |
BDD caffeine FIA system pulsed amperometry simultaneous determination uric acid |
topic |
BDD caffeine FIA system pulsed amperometry simultaneous determination uric acid |
description |
The present study reports the development and application of a flow injection analysis (FIA) system for the simultaneous determination of uric acid (UA) and caffeine (CAF) using cathodically pretreated boron-doped diamond electrode (CPT-BDD) and multiple-pulse amperometry (MPA). The electrochemical profiles of UA and CAF were analyzed via cyclic voltammetry in the potential range of 0.20–1.7 V using 0.10 mol L−1 H2SO4 solution as supporting electrolyte. Under optimized conditions, two oxidation peaks at potentials of 0.80 V (UA) and 1.4 V (CAF) were observed; the application of these potentials using multiple-pulse amperometry yielded concentration linear ranges of 5.0 × 10−8–2.2 × 10−5 mol L−1 (UA) and 5.0 × 10−8–1.9 × 10−5 mol L−1 (CAF) and limits of detection of 1.1 × 10−8 and 1.3 × 10−8 mol L−1 for UA and CAF, respectively. The proposed method exhibited good repeatability and stability, and no interference was detected in the electrochemical signals of UA and CAF in the presence of glucose, NaCl, KH2PO4, CaCl2, urea, Pb, Ni, and Cd. The application of the FIA-MPA method for the analysis of environmental samples resulted in recovery rates ranging between 98 and 104%. The results obtained showed that the BDD sensor exhibited a good analytical performance when applied for CAF and UA determination, especially when compared to other sensors reported in the literature. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-07-01 2025-04-29T18:49:25Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.3390/bios13070690 Biosensors, v. 13, n. 7, 2023. 2079-6374 https://hdl.handle.net/11449/300362 10.3390/bios13070690 2-s2.0-85166286538 |
url |
http://dx.doi.org/10.3390/bios13070690 https://hdl.handle.net/11449/300362 |
identifier_str_mv |
Biosensors, v. 13, n. 7, 2023. 2079-6374 10.3390/bios13070690 2-s2.0-85166286538 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Biosensors |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834482906347601920 |