LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes
| Main Author: | |
|---|---|
| Publication Date: | 2021 |
| Other Authors: | , , |
| Format: | Article |
| Language: | eng |
| Source: | Repositório Institucional da UNESP |
| Download full: | http://dx.doi.org/10.1016/j.pdpdt.2021.102511 http://hdl.handle.net/11449/231590 |
Summary: | BACKGROUND: The association of low concentration hydrogen peroxide (HP) and a light source has been widely used to achieve efficient bleaching. We investigated the colorimetric and microstructural changes of bovine enamel bleached with 6% HP associated or not with a hybrid light source system of violet light and laser (LED/laser). METHODS: Twenty bovine crowns were used to obtain specimens of 7 × 7 × 2 mm. Then, they were randomized in two groups (n=10): 6% HP and 6% HP + LED/laser. After staining with dark tea solution, three bleaching sessions were performed. Colorimetric evaluation (∆L*, ∆a*, ∆b*, ∆E00 [CIEDE2000] and WID) after 24 hours of each session and 7 days after the final bleaching session was performed. Enamel Vickers microhardness at baseline, 24 hours and 7 days after the last bleaching session were also evaluated. Two-way repeated measures ANOVA and Bonferroni post-test was used at a significance level of 5%. RESULTS: 6% HP and 6% + HP LED/laser showed satisfactory bleaching results. The group photoactivated showed higher WID values (p<0.05). Differences between groups were observed for ∆E00, ∆L* and ∆a* (p<0.05), except for ∆b* (p>0.05). Intra-group differences were also found (p<0.05). Regarding microhardness, no inter or intra-group differences were observed (p>0.05). CONCLUSIONS: The photoactivation with LED/laser enhanced the whitening efficacy of 6% HP compared to the group without photoactivation. Thus, the LED/laser activation appears to be a good option when using low concentration HP-based agents. In addition, both bleaching protocols did not cause changes on enamel microhardness. |
| id |
UNSP_83c3928f8a53c7a9fcdca4769e0ae47a |
|---|---|
| oai_identifier_str |
oai:repositorio.unesp.br:11449/231590 |
| network_acronym_str |
UNSP |
| network_name_str |
Repositório Institucional da UNESP |
| repository_id_str |
2946 |
| spelling |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changesColor changeDental bleachingHydrogen peroxideLaserLEDMicrohardnessBACKGROUND: The association of low concentration hydrogen peroxide (HP) and a light source has been widely used to achieve efficient bleaching. We investigated the colorimetric and microstructural changes of bovine enamel bleached with 6% HP associated or not with a hybrid light source system of violet light and laser (LED/laser). METHODS: Twenty bovine crowns were used to obtain specimens of 7 × 7 × 2 mm. Then, they were randomized in two groups (n=10): 6% HP and 6% HP + LED/laser. After staining with dark tea solution, three bleaching sessions were performed. Colorimetric evaluation (∆L*, ∆a*, ∆b*, ∆E00 [CIEDE2000] and WID) after 24 hours of each session and 7 days after the final bleaching session was performed. Enamel Vickers microhardness at baseline, 24 hours and 7 days after the last bleaching session were also evaluated. Two-way repeated measures ANOVA and Bonferroni post-test was used at a significance level of 5%. RESULTS: 6% HP and 6% + HP LED/laser showed satisfactory bleaching results. The group photoactivated showed higher WID values (p<0.05). Differences between groups were observed for ∆E00, ∆L* and ∆a* (p<0.05), except for ∆b* (p>0.05). Intra-group differences were also found (p<0.05). Regarding microhardness, no inter or intra-group differences were observed (p>0.05). CONCLUSIONS: The photoactivation with LED/laser enhanced the whitening efficacy of 6% HP compared to the group without photoactivation. Thus, the LED/laser activation appears to be a good option when using low concentration HP-based agents. In addition, both bleaching protocols did not cause changes on enamel microhardness.Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, BrazilUniversidade Estadual Paulista (UNESP)Costa, Joatan Lucas de Sousa GomesBesegato, João FelipeZaniboni, Joissi FerrariKuga, Milton Carlos2022-04-29T08:46:18Z2022-04-29T08:46:18Z2021-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article102511http://dx.doi.org/10.1016/j.pdpdt.2021.102511Photodiagnosis and photodynamic therapy, v. 36, p. 102511-.1873-1597http://hdl.handle.net/11449/23159010.1016/j.pdpdt.2021.1025112-s2.0-85122546937Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengPhotodiagnosis and photodynamic therapyinfo:eu-repo/semantics/openAccess2025-04-18T09:35:16Zoai:repositorio.unesp.br:11449/231590Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-04-18T09:35:16Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
| dc.title.none.fl_str_mv |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| title |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| spellingShingle |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes Costa, Joatan Lucas de Sousa Gomes Color change Dental bleaching Hydrogen peroxide Laser LED Microhardness |
| title_short |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| title_full |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| title_fullStr |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| title_full_unstemmed |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| title_sort |
LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes |
| author |
Costa, Joatan Lucas de Sousa Gomes |
| author_facet |
Costa, Joatan Lucas de Sousa Gomes Besegato, João Felipe Zaniboni, Joissi Ferrari Kuga, Milton Carlos |
| author_role |
author |
| author2 |
Besegato, João Felipe Zaniboni, Joissi Ferrari Kuga, Milton Carlos |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
| dc.contributor.author.fl_str_mv |
Costa, Joatan Lucas de Sousa Gomes Besegato, João Felipe Zaniboni, Joissi Ferrari Kuga, Milton Carlos |
| dc.subject.por.fl_str_mv |
Color change Dental bleaching Hydrogen peroxide Laser LED Microhardness |
| topic |
Color change Dental bleaching Hydrogen peroxide Laser LED Microhardness |
| description |
BACKGROUND: The association of low concentration hydrogen peroxide (HP) and a light source has been widely used to achieve efficient bleaching. We investigated the colorimetric and microstructural changes of bovine enamel bleached with 6% HP associated or not with a hybrid light source system of violet light and laser (LED/laser). METHODS: Twenty bovine crowns were used to obtain specimens of 7 × 7 × 2 mm. Then, they were randomized in two groups (n=10): 6% HP and 6% HP + LED/laser. After staining with dark tea solution, three bleaching sessions were performed. Colorimetric evaluation (∆L*, ∆a*, ∆b*, ∆E00 [CIEDE2000] and WID) after 24 hours of each session and 7 days after the final bleaching session was performed. Enamel Vickers microhardness at baseline, 24 hours and 7 days after the last bleaching session were also evaluated. Two-way repeated measures ANOVA and Bonferroni post-test was used at a significance level of 5%. RESULTS: 6% HP and 6% + HP LED/laser showed satisfactory bleaching results. The group photoactivated showed higher WID values (p<0.05). Differences between groups were observed for ∆E00, ∆L* and ∆a* (p<0.05), except for ∆b* (p>0.05). Intra-group differences were also found (p<0.05). Regarding microhardness, no inter or intra-group differences were observed (p>0.05). CONCLUSIONS: The photoactivation with LED/laser enhanced the whitening efficacy of 6% HP compared to the group without photoactivation. Thus, the LED/laser activation appears to be a good option when using low concentration HP-based agents. In addition, both bleaching protocols did not cause changes on enamel microhardness. |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2021-12-01 2022-04-29T08:46:18Z 2022-04-29T08:46:18Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.pdpdt.2021.102511 Photodiagnosis and photodynamic therapy, v. 36, p. 102511-. 1873-1597 http://hdl.handle.net/11449/231590 10.1016/j.pdpdt.2021.102511 2-s2.0-85122546937 |
| url |
http://dx.doi.org/10.1016/j.pdpdt.2021.102511 http://hdl.handle.net/11449/231590 |
| identifier_str_mv |
Photodiagnosis and photodynamic therapy, v. 36, p. 102511-. 1873-1597 10.1016/j.pdpdt.2021.102511 2-s2.0-85122546937 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
Photodiagnosis and photodynamic therapy |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
102511 |
| dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
| instname_str |
Universidade Estadual Paulista (UNESP) |
| instacron_str |
UNESP |
| institution |
UNESP |
| reponame_str |
Repositório Institucional da UNESP |
| collection |
Repositório Institucional da UNESP |
| repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
| repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
| _version_ |
1834482396431384576 |