Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser

Bibliographic Details
Main Author: Costa, Joatan Lucas de Sousa Gomes
Publication Date: 2023
Other Authors: Gelio, Mariana Bena [UNESP], Galvani, Lucas David [UNESP], Besegato, João Felipe, Bordini, Ester Alves Ferreira, Godoy, Eduardo Fernández, Vaz, Luis Geraldo [UNESP], Kuga, Milton Carlos
Format: Article
Language: eng
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.4012/dmj.2023-017
https://hdl.handle.net/11449/305220
Summary: This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10-15-and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.
id UNSP_0330f14b07c56c40060a47cf4394ff43
oai_identifier_str oai:repositorio.unesp.br:11449/305220
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laserDental bleachingHydrogen peroxideTemperatureViolet LEDThis study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10-15-and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Department of Restorative Dentistry School of Dentistry Federal University of Minas Gerais —UFMG, MGDepartment of Restorative Dentistry School of Dentistry São Paulo State University —UNESP, SPSchool of Dentistry Federal University of Mato Grosso do Sul —UFMS, MSDepartment of Operative Dentistry Endodontics and Dental Materials Bauru School of Dentistry University of São Paulo —USP, SPInstituto de Ciencias Biomédicas Universidad Autónoma de ChileDepartment of Dental Materials and Prosthodontics School of Dentistry São Paulo State University —UNESP, SPDepartment of Restorative Dentistry School of Dentistry São Paulo State University —UNESP, SPDepartment of Dental Materials and Prosthodontics School of Dentistry São Paulo State University —UNESP, SPCAPES: 001Universidade Federal de Minas Gerais (UFMG)Universidade Estadual Paulista (UNESP)Universidade Federal de Mato Grosso do Sul (UFMS)Universidade de São Paulo (USP)Universidad Autónoma de ChileCosta, Joatan Lucas de Sousa GomesGelio, Mariana Bena [UNESP]Galvani, Lucas David [UNESP]Besegato, João FelipeBordini, Ester Alves FerreiraGodoy, Eduardo FernándezVaz, Luis Geraldo [UNESP]Kuga, Milton Carlos2025-04-29T20:02:28Z2023-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article654-658http://dx.doi.org/10.4012/dmj.2023-017Dental Materials Journal, v. 42, n. 5, p. 654-658, 2023.1881-13610287-4547https://hdl.handle.net/11449/30522010.4012/dmj.2023-0172-s2.0-85173515376Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengDental Materials Journalinfo:eu-repo/semantics/openAccess2025-04-30T14:32:10Zoai:repositorio.unesp.br:11449/305220Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-04-30T14:32:10Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
title Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
spellingShingle Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
Costa, Joatan Lucas de Sousa Gomes
Dental bleaching
Hydrogen peroxide
Temperature
Violet LED
title_short Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
title_full Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
title_fullStr Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
title_full_unstemmed Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
title_sort Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
author Costa, Joatan Lucas de Sousa Gomes
author_facet Costa, Joatan Lucas de Sousa Gomes
Gelio, Mariana Bena [UNESP]
Galvani, Lucas David [UNESP]
Besegato, João Felipe
Bordini, Ester Alves Ferreira
Godoy, Eduardo Fernández
Vaz, Luis Geraldo [UNESP]
Kuga, Milton Carlos
author_role author
author2 Gelio, Mariana Bena [UNESP]
Galvani, Lucas David [UNESP]
Besegato, João Felipe
Bordini, Ester Alves Ferreira
Godoy, Eduardo Fernández
Vaz, Luis Geraldo [UNESP]
Kuga, Milton Carlos
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de Minas Gerais (UFMG)
Universidade Estadual Paulista (UNESP)
Universidade Federal de Mato Grosso do Sul (UFMS)
Universidade de São Paulo (USP)
Universidad Autónoma de Chile
dc.contributor.author.fl_str_mv Costa, Joatan Lucas de Sousa Gomes
Gelio, Mariana Bena [UNESP]
Galvani, Lucas David [UNESP]
Besegato, João Felipe
Bordini, Ester Alves Ferreira
Godoy, Eduardo Fernández
Vaz, Luis Geraldo [UNESP]
Kuga, Milton Carlos
dc.subject.por.fl_str_mv Dental bleaching
Hydrogen peroxide
Temperature
Violet LED
topic Dental bleaching
Hydrogen peroxide
Temperature
Violet LED
description This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10-15-and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.
publishDate 2023
dc.date.none.fl_str_mv 2023-01-01
2025-04-29T20:02:28Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.4012/dmj.2023-017
Dental Materials Journal, v. 42, n. 5, p. 654-658, 2023.
1881-1361
0287-4547
https://hdl.handle.net/11449/305220
10.4012/dmj.2023-017
2-s2.0-85173515376
url http://dx.doi.org/10.4012/dmj.2023-017
https://hdl.handle.net/11449/305220
identifier_str_mv Dental Materials Journal, v. 42, n. 5, p. 654-658, 2023.
1881-1361
0287-4547
10.4012/dmj.2023-017
2-s2.0-85173515376
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Dental Materials Journal
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 654-658
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834482949772279808