PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO

Bibliographic Details
Main Author: Rosa, Arthur de Araújo
Publication Date: 2021
Format: Other
Language: por
Source: Repositório Institucional da UFSC
dARK ID: ark:/67038/001300001rs1k
Download full: https://repositorio.ufsc.br/handle/123456789/227296
Summary: Seminário de Iniciação Científica e Tecnológica - Universidade Federal de Santa Catarina. Centro de Desportos. Educação Física - Bacharelado.
id UFSC_737e9afd5820f73379fccd2ee01954db
oai_identifier_str oai:repositorio.ufsc.br:123456789/227296
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMOConsumo máximo de oxigênio. Desempenho. Endurance.Maximal oxygen uptake. Performance. EnduranceSeminário de Iniciação Científica e Tecnológica - Universidade Federal de Santa Catarina. Centro de Desportos. Educação Física - Bacharelado.O objetivo deste estudo foi conferir a predição da tolerância ao exercício, em cicloergômetro, nos domínios de intensidade severo e extremo, através de diferentes modelos de potência crítica (PC). A amostra consistiu-se de 19 participantes (idade: 23,0 ± 2,7 anos; massa corporal: 77,8 ± 6,2 kg; estatura: 175,3 ± 5,3 cm; V̇ O2max 49,4 ± 5,6 ml.kg-1 .min-1 ), os quais realizaram três etapas de diferentes testes em cicloergômetro: I) Teste incremental com carga inicial de 0,5 W∙kg-1 e incrementos de 0,5 W∙kg-1 , a cada 3 minutos, até exaustão, com intuito de determinar a potência máxima do teste incremental (Pmáx); II) Dois a três testes de tempo de exaustão (Tlim) a fim de estabelecer a maior intensidade de exercício constante na qual o V̇ O2max é alcançado (ISUP, domínio severo) e a intensidade 5% acima da ISUP (ISUP+5%, domínio extremo); III) Três testes de Tlim nas intensidades 95%, 100% ou 110% da Pmáx para determinar a PC e a capacidade finita de trabalho acima da PC (W’). Os modelos “linear trabalho × tempo (Linear-TW(3))”, “linear potência × inverso do tempo (Linear-P)” e “hiperbólico potência × tempo (Hiper-2P)” foram utilizados para a determinação de PC e W’, quando com base nas 3 cargas preditivas. Ademais, quando utilizando-se de 2 cargas preditivas (95% e 110% da Pmáx) para a determinação de PC e W’, o modelo utilizado foi o linear trabalho × tempo (Linear-TW(2)). Com o uso da ANOVA medidas repetidas, complementada pelo erro típico de estimativa e análise de concordância, o Tlim dos testes de domínio severo (ISUP) e domínio extremo (ISUP+5%) foram comparados com os Tlim preditos pelos quatro modelos de PC e W’. Adicionalmente, foi efetuada uma comparação de PC e W’ entre os diferentes modelos. Adotou-se um nível de significância de p ≤ 0,05. De acordo com os resultados, não ocorreu diferença significativa de PC e W’ quando comparados entre os diferentes modelos (p>0,05). Ademais, não se observou diferença significativa entre o Tlim real e aqueles preditos através dos modelos de PC para ISUP. Ainda, observou-se diferença somente entre Tlim real (Tlim: 120 ± 26s) e o previsto pelo modelo Linear-TW(2) (Tlim: 129 ± 33s) para ISUP+5% (p<0,05). Conclui-se que PC e W’, estimados por 3 cargas preditivas, podem predizer o Tlim em intensidades de transição entre os domínios “severo” e “extremo”, apesar de existir grande variabilidade individual. No que tange ao modelo com 2 cargas preditivas, apesar de ter sido capaz de predizer Tlim na ISUP com bias de apenas 0,7%, sua utilização deve ser feita com cuidado, haja vista que superestimou em aproximadamente 6,5% a tolerância ao exercício no domínio extremo.This study aimed to verify the prediction of the exercise tolerance, in a cycle ergometer, at the severe and the extreme intensity domains, by using different critical power (CP) models. Nineteen recreationally trained cyclists (age: 23.0 ± 2.7 years; body mass: 77.8 ± 6.2 kg; height: 175.3 ± 5.3 cm; V̇ O2max: 49.4 ± 5.6 ml.kg-1 .min-1 )performed, on a cycle ergometer, the following tests: I) Incremental test with initial load of 0.5 W∙kg-1 and increments of 0.5 W∙kg-1 at each stage of 3 minutes until exhaustion, in order to determine the maximum power output of the incremental test (Pmax); II) Two to three time to exhaustion tests (Tlim) to determine the highest intensity at which V̇ O2max can be achieved (ISUP) and the intensity 5% above ISUP (ISUP +5%); III) Three Tlim tests at 95, 100 or 110% of Pmax to determine CP and finite work capacity above CP (W’). The CP and W’ were estimated from the three predictive trials according to the two parameters models of linear work × time (Linear-TW(3)), linear power × inverse of time (Linear-P) and hyperbolic power × time (Hyper-2P). Furthermore, the CP and W’ were determined using the work × time model with 2 predictive trials (Linear-TW(2)) of the extremities (95 and 110% of Pmax). The Tlim of the ISUP (severe intensity domain) and ISUP+5% (extreme intensity domain) trials were compared with the Tlim predicted by the four CP and W’ models by using ANOVA for repeated measures along with the typical error of estimate and agreement analyzes. Additionally, CP and W’ obtained through different models were compared. The significance level adopted in all tests was 0.05. There was no significant difference for CP and W’ determined by different models (p > 0.05). There was no significant difference among the actual and the predicted Tlim by CP models for ISUP. A significant difference was only described between actual (120 ± 26 s) and predicted (129 ± 33 s) Tlim by Linear-TW(2) model for ISUP+5% (p < 0.05). In conclusion, Tlim at the intensities transitioning from the severe to the extreme domains can be predicted by the CP and W’ models with three predictive trials, despite the individual variability. Although the CP model with two predictive trials was able to predict Tlim at ISUP with a bias of only 0.7%, it is necessary caution in its application because exercise tolerance at the extreme intensity domain was overestimated by almost 6,5%.Florianópolis, SCTurnes, TiagoVentura, Thiago PereiraUNIVERSIDADE FEDERAL DE SANTA CATARINARosa, Arthur de Araújo2021-08-23T20:20:40Z2021-08-23T20:20:40Z2021-08-23info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/other20video/mp4https://repositorio.ufsc.br/handle/123456789/227296ark:/67038/001300001rs1kporreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2021-08-23T20:20:40Zoai:repositorio.ufsc.br:123456789/227296Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestsandra.sobrera@ufsc.bropendoar:23732021-08-23T20:20:40Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
title PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
spellingShingle PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
Rosa, Arthur de Araújo
Consumo máximo de oxigênio. Desempenho. Endurance.
Maximal oxygen uptake. Performance. Endurance
title_short PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
title_full PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
title_fullStr PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
title_full_unstemmed PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
title_sort PREDIÇÃO DA TOLERÂNCIA AO EXERCÍCIO NOS DOMÍNIOS SEVERO E EXTREMO POR DIFERENTES MODELOS DE POTÊNCIA CRÍTICA NO CICLISMO
author Rosa, Arthur de Araújo
author_facet Rosa, Arthur de Araújo
author_role author
dc.contributor.none.fl_str_mv Turnes, Tiago
Ventura, Thiago Pereira
UNIVERSIDADE FEDERAL DE SANTA CATARINA
dc.contributor.author.fl_str_mv Rosa, Arthur de Araújo
dc.subject.por.fl_str_mv Consumo máximo de oxigênio. Desempenho. Endurance.
Maximal oxygen uptake. Performance. Endurance
topic Consumo máximo de oxigênio. Desempenho. Endurance.
Maximal oxygen uptake. Performance. Endurance
description Seminário de Iniciação Científica e Tecnológica - Universidade Federal de Santa Catarina. Centro de Desportos. Educação Física - Bacharelado.
publishDate 2021
dc.date.none.fl_str_mv 2021-08-23T20:20:40Z
2021-08-23T20:20:40Z
2021-08-23
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/other
format other
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/227296
dc.identifier.dark.fl_str_mv ark:/67038/001300001rs1k
url https://repositorio.ufsc.br/handle/123456789/227296
identifier_str_mv ark:/67038/001300001rs1k
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 20
video/mp4
dc.publisher.none.fl_str_mv Florianópolis, SC
publisher.none.fl_str_mv Florianópolis, SC
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv sandra.sobrera@ufsc.br
_version_ 1839033409128628224