Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating

Bibliographic Details
Main Author: Calderoni,Davi Reis
Publication Date: 2014
Other Authors: Gilioli,Rovilson, Munhoz,André Luiz Jardini, Maciel Filho,Rubens, Zavaglia,Cecília Amélia de Carvalho, Lambert,Carlos Salles, Lopes,Éder Socrates Najar, Toro,Ivan Felizardo Contrera, Kharmandayan,Paulo
Format: Article
Language: eng
Source: Acta Cirúrgica Brasileira (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502014000900579
Summary: PURPOSE:To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating.METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy.RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants.CONCLUSION:Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.
id SBDPC-1_0126886e99a34c7a3e263de03e20a05c
oai_identifier_str oai:scielo:S0102-86502014000900579
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coatingTitaniumSkullOsseointegrationProstheses and ImplantsBiocompatible MaterialsCeramicsRatsPURPOSE:To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating.METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy.RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants.CONCLUSION:Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2014-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502014000900579Acta Cirúrgica Brasileira v.29 n.9 2014reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-8650201400150005info:eu-repo/semantics/openAccessCalderoni,Davi ReisGilioli,RovilsonMunhoz,André Luiz JardiniMaciel Filho,RubensZavaglia,Cecília Amélia de CarvalhoLambert,Carlos SallesLopes,Éder Socrates NajarToro,Ivan Felizardo ContreraKharmandayan,Pauloeng2015-10-27T00:00:00Zoai:scielo:S0102-86502014000900579Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2015-10-27T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
title Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
spellingShingle Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
Calderoni,Davi Reis
Titanium
Skull
Osseointegration
Prostheses and Implants
Biocompatible Materials
Ceramics
Rats
title_short Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
title_full Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
title_fullStr Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
title_full_unstemmed Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
title_sort Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
author Calderoni,Davi Reis
author_facet Calderoni,Davi Reis
Gilioli,Rovilson
Munhoz,André Luiz Jardini
Maciel Filho,Rubens
Zavaglia,Cecília Amélia de Carvalho
Lambert,Carlos Salles
Lopes,Éder Socrates Najar
Toro,Ivan Felizardo Contrera
Kharmandayan,Paulo
author_role author
author2 Gilioli,Rovilson
Munhoz,André Luiz Jardini
Maciel Filho,Rubens
Zavaglia,Cecília Amélia de Carvalho
Lambert,Carlos Salles
Lopes,Éder Socrates Najar
Toro,Ivan Felizardo Contrera
Kharmandayan,Paulo
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Calderoni,Davi Reis
Gilioli,Rovilson
Munhoz,André Luiz Jardini
Maciel Filho,Rubens
Zavaglia,Cecília Amélia de Carvalho
Lambert,Carlos Salles
Lopes,Éder Socrates Najar
Toro,Ivan Felizardo Contrera
Kharmandayan,Paulo
dc.subject.por.fl_str_mv Titanium
Skull
Osseointegration
Prostheses and Implants
Biocompatible Materials
Ceramics
Rats
topic Titanium
Skull
Osseointegration
Prostheses and Implants
Biocompatible Materials
Ceramics
Rats
description PURPOSE:To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating.METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy.RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants.CONCLUSION:Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.
publishDate 2014
dc.date.none.fl_str_mv 2014-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502014000900579
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502014000900579
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-8650201400150005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.29 n.9 2014
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126442660954112