Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review

Detalhes bibliográficos
Autor(a) principal: López-Valverde, Nansi
Data de Publicação: 2021
Outros Autores: Sousa, Bruno Macedo de, López-Valverde, Antonio, Ramírez, Juan Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: https://hdl.handle.net/10316/103677
https://doi.org/10.3390/antibiotics10040360
Resumo: Titanium (Ti) dental implant failure as a result of infection has been established at 40%, being regarded as one of the most habitual and untreatable problems. Current research is focused on the design of new surfaces that can generate long-lasting, infection-free osseointegration. The purpose of our study was to assess studies on Ti implants coated with different antibacterial surfaces, assessing their osseointegration. The PubMed, Web of Science and Scopus databases were electronically searched for in vivo studies up to December 2020, selecting six studies that met the inclusion criteria. The quality of the selected studies was assessed using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) criteria and Systematic Review Center for Laboratory animal Experimentation's (SYRCLE's) risk of bias tool. Although all the included studies, proved greater osseointegration capacity of the different antibacterial surfaces studied, the methodological quality and experimental models used in some of them make it difficult to draw predictable conclusions. Because of the foregoing, we recommend caution when interpreting the results obtained.
id RCAP_cd8a4cfd5934f0b1ab8288e12dab4048
oai_identifier_str oai:estudogeral.uc.pt:10316/103677
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Reviewtitanium dental implantsantibacterial coating surfacesosseointegrationTitanium (Ti) dental implant failure as a result of infection has been established at 40%, being regarded as one of the most habitual and untreatable problems. Current research is focused on the design of new surfaces that can generate long-lasting, infection-free osseointegration. The purpose of our study was to assess studies on Ti implants coated with different antibacterial surfaces, assessing their osseointegration. The PubMed, Web of Science and Scopus databases were electronically searched for in vivo studies up to December 2020, selecting six studies that met the inclusion criteria. The quality of the selected studies was assessed using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) criteria and Systematic Review Center for Laboratory animal Experimentation's (SYRCLE's) risk of bias tool. Although all the included studies, proved greater osseointegration capacity of the different antibacterial surfaces studied, the methodological quality and experimental models used in some of them make it difficult to draw predictable conclusions. Because of the foregoing, we recommend caution when interpreting the results obtained.MDPI AG2021-03-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://hdl.handle.net/10316/103677https://hdl.handle.net/10316/103677https://doi.org/10.3390/antibiotics10040360eng2079-6382López-Valverde, NansiSousa, Bruno Macedo deLópez-Valverde, AntonioRamírez, Juan Manuelinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2022-11-21T21:36:46Zoai:estudogeral.uc.pt:10316/103677Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:53:34.559103Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
title Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
spellingShingle Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
López-Valverde, Nansi
titanium dental implants
antibacterial coating surfaces
osseointegration
title_short Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
title_full Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
title_fullStr Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
title_full_unstemmed Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
title_sort Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
author López-Valverde, Nansi
author_facet López-Valverde, Nansi
Sousa, Bruno Macedo de
López-Valverde, Antonio
Ramírez, Juan Manuel
author_role author
author2 Sousa, Bruno Macedo de
López-Valverde, Antonio
Ramírez, Juan Manuel
author2_role author
author
author
dc.contributor.author.fl_str_mv López-Valverde, Nansi
Sousa, Bruno Macedo de
López-Valverde, Antonio
Ramírez, Juan Manuel
dc.subject.por.fl_str_mv titanium dental implants
antibacterial coating surfaces
osseointegration
topic titanium dental implants
antibacterial coating surfaces
osseointegration
description Titanium (Ti) dental implant failure as a result of infection has been established at 40%, being regarded as one of the most habitual and untreatable problems. Current research is focused on the design of new surfaces that can generate long-lasting, infection-free osseointegration. The purpose of our study was to assess studies on Ti implants coated with different antibacterial surfaces, assessing their osseointegration. The PubMed, Web of Science and Scopus databases were electronically searched for in vivo studies up to December 2020, selecting six studies that met the inclusion criteria. The quality of the selected studies was assessed using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) criteria and Systematic Review Center for Laboratory animal Experimentation's (SYRCLE's) risk of bias tool. Although all the included studies, proved greater osseointegration capacity of the different antibacterial surfaces studied, the methodological quality and experimental models used in some of them make it difficult to draw predictable conclusions. Because of the foregoing, we recommend caution when interpreting the results obtained.
publishDate 2021
dc.date.none.fl_str_mv 2021-03-28
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10316/103677
https://hdl.handle.net/10316/103677
https://doi.org/10.3390/antibiotics10040360
url https://hdl.handle.net/10316/103677
https://doi.org/10.3390/antibiotics10040360
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2079-6382
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv MDPI AG
publisher.none.fl_str_mv MDPI AG
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602508657786880