Determination of 2,4,6-trichloroanisole by cyclic voltammetry

Bibliographic Details
Main Author: Freitas, P.
Publication Date: 2012
Other Authors: Dias, Luís G., Peres, A. M., Castro, L. M., Veloso, Ana C. A.
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/1822/23379
Summary: The electrochemical reduction of 2,4,6-trichloroanisole (TCA), a chlorinated arene with electron-donating substituents, was evaluated by cyclic voltammetry (CV). TCA is a major concern for the winery industry since it is related with “cork taint”, a wine defect. The results obtained showed that CV could be used to detect and quantify TCA in standard solutions. Linear relationships could be set between the current amplitude and TCA concentrations (R>0.990) with detection and quantification limits of 0.08 and 0.26 ppm. Although, these preliminary limits are higher than the human sensory threshold (5 ppt in wine), the simplicity of the methodology confers this study a possible role in the development of more efficient and less expensive process for TCA detection in the industry.
id RCAP_e9a12ba0593b9bbe72a44a8fb48281ee
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/23379
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Determination of 2,4,6-trichloroanisole by cyclic voltammetry2,4,6-TrichloroanisoleCork taintCyclic voltammetryScience & TechnologyThe electrochemical reduction of 2,4,6-trichloroanisole (TCA), a chlorinated arene with electron-donating substituents, was evaluated by cyclic voltammetry (CV). TCA is a major concern for the winery industry since it is related with “cork taint”, a wine defect. The results obtained showed that CV could be used to detect and quantify TCA in standard solutions. Linear relationships could be set between the current amplitude and TCA concentrations (R>0.990) with detection and quantification limits of 0.08 and 0.26 ppm. Although, these preliminary limits are higher than the human sensory threshold (5 ppt in wine), the simplicity of the methodology confers this study a possible role in the development of more efficient and less expensive process for TCA detection in the industry.This work was partially supported by project PEst-C/EQB/LA0020/2011, financed by FEDER through COMPETE - Programa Operacional Factores de Competitividade and by FCT - Fundacao para a Ciencia e a Tecnologia.ElsevierElsevier BVUniversidade do MinhoFreitas, P.Dias, Luís G.Peres, A. M.Castro, L. M.Veloso, Ana C. A.20122012-01-01T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/1822/23379eng1877-70581877-705810.1016/j.proeng.2012.09.349info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-12T05:12:13Zoai:repositorium.sdum.uminho.pt:1822/23379Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:12:53.253981Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Determination of 2,4,6-trichloroanisole by cyclic voltammetry
title Determination of 2,4,6-trichloroanisole by cyclic voltammetry
spellingShingle Determination of 2,4,6-trichloroanisole by cyclic voltammetry
Freitas, P.
2,4,6-Trichloroanisole
Cork taint
Cyclic voltammetry
Science & Technology
title_short Determination of 2,4,6-trichloroanisole by cyclic voltammetry
title_full Determination of 2,4,6-trichloroanisole by cyclic voltammetry
title_fullStr Determination of 2,4,6-trichloroanisole by cyclic voltammetry
title_full_unstemmed Determination of 2,4,6-trichloroanisole by cyclic voltammetry
title_sort Determination of 2,4,6-trichloroanisole by cyclic voltammetry
author Freitas, P.
author_facet Freitas, P.
Dias, Luís G.
Peres, A. M.
Castro, L. M.
Veloso, Ana C. A.
author_role author
author2 Dias, Luís G.
Peres, A. M.
Castro, L. M.
Veloso, Ana C. A.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Freitas, P.
Dias, Luís G.
Peres, A. M.
Castro, L. M.
Veloso, Ana C. A.
dc.subject.por.fl_str_mv 2,4,6-Trichloroanisole
Cork taint
Cyclic voltammetry
Science & Technology
topic 2,4,6-Trichloroanisole
Cork taint
Cyclic voltammetry
Science & Technology
description The electrochemical reduction of 2,4,6-trichloroanisole (TCA), a chlorinated arene with electron-donating substituents, was evaluated by cyclic voltammetry (CV). TCA is a major concern for the winery industry since it is related with “cork taint”, a wine defect. The results obtained showed that CV could be used to detect and quantify TCA in standard solutions. Linear relationships could be set between the current amplitude and TCA concentrations (R>0.990) with detection and quantification limits of 0.08 and 0.26 ppm. Although, these preliminary limits are higher than the human sensory threshold (5 ppt in wine), the simplicity of the methodology confers this study a possible role in the development of more efficient and less expensive process for TCA detection in the industry.
publishDate 2012
dc.date.none.fl_str_mv 2012
2012-01-01T00:00:00Z
dc.type.driver.fl_str_mv conference paper
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/23379
url https://hdl.handle.net/1822/23379
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1877-7058
1877-7058
10.1016/j.proeng.2012.09.349
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
Elsevier BV
publisher.none.fl_str_mv Elsevier
Elsevier BV
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595809515438080