Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide

Bibliographic Details
Main Author: Zaazaa,H.E.
Publication Date: 2012
Other Authors: Abbas,S.S., Essam,Hebat A.M., El-Bardicy,M. G.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004
Summary: Four torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found.
id RCAP_e3d532ac4f98dfda29dba0980e911f0b
oai_identifier_str oai:scielo:S0872-19042012000500004
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of TorsemideTorsemide-selective electrodegraphite electrode2-hydroxy propyl-βcyclodextrinstability indicating studypharmaceutical dosage formFour torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found.Sociedade Portuguesa de Electroquímica2012-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004Portugaliae Electrochimica Acta v.30 n.5 2012reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004Zaazaa,H.E.Abbas,S.S.Essam,Hebat A.M.El-Bardicy,M. G.info:eu-repo/semantics/openAccess2024-02-06T17:07:11Zoai:scielo:S0872-19042012000500004Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:56:31.318872Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
title Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
spellingShingle Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
Zaazaa,H.E.
Torsemide-selective electrode
graphite electrode
2-hydroxy propyl-βcyclodextrin
stability indicating study
pharmaceutical dosage form
title_short Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
title_full Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
title_fullStr Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
title_full_unstemmed Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
title_sort Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
author Zaazaa,H.E.
author_facet Zaazaa,H.E.
Abbas,S.S.
Essam,Hebat A.M.
El-Bardicy,M. G.
author_role author
author2 Abbas,S.S.
Essam,Hebat A.M.
El-Bardicy,M. G.
author2_role author
author
author
dc.contributor.author.fl_str_mv Zaazaa,H.E.
Abbas,S.S.
Essam,Hebat A.M.
El-Bardicy,M. G.
dc.subject.por.fl_str_mv Torsemide-selective electrode
graphite electrode
2-hydroxy propyl-βcyclodextrin
stability indicating study
pharmaceutical dosage form
topic Torsemide-selective electrode
graphite electrode
2-hydroxy propyl-βcyclodextrin
stability indicating study
pharmaceutical dosage form
description Four torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found.
publishDate 2012
dc.date.none.fl_str_mv 2012-09-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Electroquímica
publisher.none.fl_str_mv Sociedade Portuguesa de Electroquímica
dc.source.none.fl_str_mv Portugaliae Electrochimica Acta v.30 n.5 2012
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833593268816838656