Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
| Main Author: | |
|---|---|
| Publication Date: | 2012 |
| Other Authors: | , , |
| Format: | Article |
| Language: | eng |
| Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Download full: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
Summary: | Four torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found. |
| id |
RCAP_e3d532ac4f98dfda29dba0980e911f0b |
|---|---|
| oai_identifier_str |
oai:scielo:S0872-19042012000500004 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of TorsemideTorsemide-selective electrodegraphite electrode2-hydroxy propyl-βcyclodextrinstability indicating studypharmaceutical dosage formFour torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found.Sociedade Portuguesa de Electroquímica2012-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004Portugaliae Electrochimica Acta v.30 n.5 2012reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004Zaazaa,H.E.Abbas,S.S.Essam,Hebat A.M.El-Bardicy,M. G.info:eu-repo/semantics/openAccess2024-02-06T17:07:11Zoai:scielo:S0872-19042012000500004Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:56:31.318872Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| title |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| spellingShingle |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide Zaazaa,H.E. Torsemide-selective electrode graphite electrode 2-hydroxy propyl-βcyclodextrin stability indicating study pharmaceutical dosage form |
| title_short |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| title_full |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| title_fullStr |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| title_full_unstemmed |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| title_sort |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
| author |
Zaazaa,H.E. |
| author_facet |
Zaazaa,H.E. Abbas,S.S. Essam,Hebat A.M. El-Bardicy,M. G. |
| author_role |
author |
| author2 |
Abbas,S.S. Essam,Hebat A.M. El-Bardicy,M. G. |
| author2_role |
author author author |
| dc.contributor.author.fl_str_mv |
Zaazaa,H.E. Abbas,S.S. Essam,Hebat A.M. El-Bardicy,M. G. |
| dc.subject.por.fl_str_mv |
Torsemide-selective electrode graphite electrode 2-hydroxy propyl-βcyclodextrin stability indicating study pharmaceutical dosage form |
| topic |
Torsemide-selective electrode graphite electrode 2-hydroxy propyl-βcyclodextrin stability indicating study pharmaceutical dosage form |
| description |
Four torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012-09-01 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
| url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
text/html |
| dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
| publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
| dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.30 n.5 2012 reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833593268816838656 |