Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes
| Main Author: | |
|---|---|
| Publication Date: | 2010 |
| Other Authors: | , , |
| Format: | Article |
| Language: | eng |
| Source: | Repositório Institucional da UNESP |
| Download full: | http://dx.doi.org/10.1590/S0100-40422010000400036 http://hdl.handle.net/11449/25697 |
Summary: | An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level. |
| id |
UNSP_10c8a2d7ae45a74b14bbb69308a53310 |
|---|---|
| oai_identifier_str |
oai:repositorio.unesp.br:11449/25697 |
| network_acronym_str |
UNSP |
| network_name_str |
Repositório Institucional da UNESP |
| repository_id_str |
2946 |
| spelling |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes5-aminosalicylic acidpharmaceutical formulationspencil graphite electrodeAn analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Universidade Estadual Paulista Júlio de Mesquita Filho Instituto de QuímicaUniversidade de São Paulo Instituto de Química de São CarlosUniversidade Estadual Paulista Júlio de Mesquita Filho Instituto de QuímicaFAPESP: 06/50692-2CNPq: 475577/2007-8CNPq: 134868/2007-2CNPq: 142930/2005-9Sociedade Brasileira de QuímicaUniversidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Uliana, Carolina V. [UNESP]Yamanaka, Hideko [UNESP]Garbellini, Gustavo S.Salazar-Banda, Giancarlo R.2014-05-20T14:18:55Z2014-05-20T14:18:55Z2010-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article964-967application/pdfhttp://dx.doi.org/10.1590/S0100-40422010000400036Química Nova. Sociedade Brasileira de Química, v. 33, n. 4, p. 964-967, 2010.0100-4042http://hdl.handle.net/11449/2569710.1590/S0100-40422010000400036S0100-40422010000400036WOS:000278322500036S0100-40422010000400036.pdf1923726000036625SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengQuímica Nova0.6460,255info:eu-repo/semantics/openAccess2025-05-28T07:01:12Zoai:repositorio.unesp.br:11449/25697Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-05-28T07:01:12Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
| dc.title.none.fl_str_mv |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| title |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| spellingShingle |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes Uliana, Carolina V. [UNESP] 5-aminosalicylic acid pharmaceutical formulations pencil graphite electrode |
| title_short |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| title_full |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| title_fullStr |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| title_full_unstemmed |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| title_sort |
Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes |
| author |
Uliana, Carolina V. [UNESP] |
| author_facet |
Uliana, Carolina V. [UNESP] Yamanaka, Hideko [UNESP] Garbellini, Gustavo S. Salazar-Banda, Giancarlo R. |
| author_role |
author |
| author2 |
Yamanaka, Hideko [UNESP] Garbellini, Gustavo S. Salazar-Banda, Giancarlo R. |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade de São Paulo (USP) |
| dc.contributor.author.fl_str_mv |
Uliana, Carolina V. [UNESP] Yamanaka, Hideko [UNESP] Garbellini, Gustavo S. Salazar-Banda, Giancarlo R. |
| dc.subject.por.fl_str_mv |
5-aminosalicylic acid pharmaceutical formulations pencil graphite electrode |
| topic |
5-aminosalicylic acid pharmaceutical formulations pencil graphite electrode |
| description |
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010-01-01 2014-05-20T14:18:55Z 2014-05-20T14:18:55Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0100-40422010000400036 Química Nova. Sociedade Brasileira de Química, v. 33, n. 4, p. 964-967, 2010. 0100-4042 http://hdl.handle.net/11449/25697 10.1590/S0100-40422010000400036 S0100-40422010000400036 WOS:000278322500036 S0100-40422010000400036.pdf 1923726000036625 |
| url |
http://dx.doi.org/10.1590/S0100-40422010000400036 http://hdl.handle.net/11449/25697 |
| identifier_str_mv |
Química Nova. Sociedade Brasileira de Química, v. 33, n. 4, p. 964-967, 2010. 0100-4042 10.1590/S0100-40422010000400036 S0100-40422010000400036 WOS:000278322500036 S0100-40422010000400036.pdf 1923726000036625 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
Química Nova 0.646 0,255 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
964-967 application/pdf |
| dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
| publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
| dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
| instname_str |
Universidade Estadual Paulista (UNESP) |
| instacron_str |
UNESP |
| institution |
UNESP |
| reponame_str |
Repositório Institucional da UNESP |
| collection |
Repositório Institucional da UNESP |
| repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
| repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
| _version_ |
1854948937358639104 |