Mechanical stability of morse taper implant – abutment connection: a focused review
Main Author: | |
---|---|
Publication Date: | 2017 |
Format: | Master thesis |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10284/6348 |
Summary: | O objetivo principal deste estudo foi realizar uma revisão sistemática sobre a integridade mecânica das conexões cone Morse de implante em relação à presença de microgap e manutenção do torque. Uma ampla pesquisa eletrônica foi realizada nos bancos de dados PubMed, Embase e Medline com as palavras chaves: dental implant” e “dental abutment” e (“conical” ou “taper” ou “cone”). “removal torque” e “Morse Taper”, “torque loss” e “micro gap size” Estudos in vitro demonstraram que os pilares cônicos têm melhor desempenho, no que diz respeito ao selamento bacteriano e a manutenção do torque e estabilidade do pilar, do que os pilares não cônicos. Estudos in vivo mostraram que as taxas de sucesso e sobrevivência dos sistemas de implantes cone Morse comparadas aos outras, são quase comparáveis; porém os implantes com conexão cone Morse mostraram menor perda ossea marginal. Conclui-se , com esta revisão sistemática, que o uso de implantes com conexões cone Morse parece ser mais vantajoso, pois de mostraram ter melhor desempenho em termos de estabilidade mecânica e selamento bacteriano. |
id |
RCAP_66be906a9355c81e7111d6f1734724d7 |
---|---|
oai_identifier_str |
oai:bdigital.ufp.pt:10284/6348 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Mechanical stability of morse taper implant – abutment connection: a focused reviewSystematic reviewDental implantDental abutmentMorse taperImplant - abutment connectionMicrogap and seal performanceTorque maintenanceFatigue resistanceO objetivo principal deste estudo foi realizar uma revisão sistemática sobre a integridade mecânica das conexões cone Morse de implante em relação à presença de microgap e manutenção do torque. Uma ampla pesquisa eletrônica foi realizada nos bancos de dados PubMed, Embase e Medline com as palavras chaves: dental implant” e “dental abutment” e (“conical” ou “taper” ou “cone”). “removal torque” e “Morse Taper”, “torque loss” e “micro gap size” Estudos in vitro demonstraram que os pilares cônicos têm melhor desempenho, no que diz respeito ao selamento bacteriano e a manutenção do torque e estabilidade do pilar, do que os pilares não cônicos. Estudos in vivo mostraram que as taxas de sucesso e sobrevivência dos sistemas de implantes cone Morse comparadas aos outras, são quase comparáveis; porém os implantes com conexão cone Morse mostraram menor perda ossea marginal. Conclui-se , com esta revisão sistemática, que o uso de implantes com conexões cone Morse parece ser mais vantajoso, pois de mostraram ter melhor desempenho em termos de estabilidade mecânica e selamento bacteriano.Pereira, JorgeRepositório Institucional da Fernando PessoaAl-Dujayli, Samantha2017-12-15T10:59:49Z2017-07-182017-07-18T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10284/6348urn:tid:201911752enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-18T17:44:07Zoai:bdigital.ufp.pt:10284/6348Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T04:32:06.880331Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Mechanical stability of morse taper implant – abutment connection: a focused review |
title |
Mechanical stability of morse taper implant – abutment connection: a focused review |
spellingShingle |
Mechanical stability of morse taper implant – abutment connection: a focused review Al-Dujayli, Samantha Systematic review Dental implant Dental abutment Morse taper Implant - abutment connection Microgap and seal performance Torque maintenance Fatigue resistance |
title_short |
Mechanical stability of morse taper implant – abutment connection: a focused review |
title_full |
Mechanical stability of morse taper implant – abutment connection: a focused review |
title_fullStr |
Mechanical stability of morse taper implant – abutment connection: a focused review |
title_full_unstemmed |
Mechanical stability of morse taper implant – abutment connection: a focused review |
title_sort |
Mechanical stability of morse taper implant – abutment connection: a focused review |
author |
Al-Dujayli, Samantha |
author_facet |
Al-Dujayli, Samantha |
author_role |
author |
dc.contributor.none.fl_str_mv |
Pereira, Jorge Repositório Institucional da Fernando Pessoa |
dc.contributor.author.fl_str_mv |
Al-Dujayli, Samantha |
dc.subject.por.fl_str_mv |
Systematic review Dental implant Dental abutment Morse taper Implant - abutment connection Microgap and seal performance Torque maintenance Fatigue resistance |
topic |
Systematic review Dental implant Dental abutment Morse taper Implant - abutment connection Microgap and seal performance Torque maintenance Fatigue resistance |
description |
O objetivo principal deste estudo foi realizar uma revisão sistemática sobre a integridade mecânica das conexões cone Morse de implante em relação à presença de microgap e manutenção do torque. Uma ampla pesquisa eletrônica foi realizada nos bancos de dados PubMed, Embase e Medline com as palavras chaves: dental implant” e “dental abutment” e (“conical” ou “taper” ou “cone”). “removal torque” e “Morse Taper”, “torque loss” e “micro gap size” Estudos in vitro demonstraram que os pilares cônicos têm melhor desempenho, no que diz respeito ao selamento bacteriano e a manutenção do torque e estabilidade do pilar, do que os pilares não cônicos. Estudos in vivo mostraram que as taxas de sucesso e sobrevivência dos sistemas de implantes cone Morse comparadas aos outras, são quase comparáveis; porém os implantes com conexão cone Morse mostraram menor perda ossea marginal. Conclui-se , com esta revisão sistemática, que o uso de implantes com conexões cone Morse parece ser mais vantajoso, pois de mostraram ter melhor desempenho em termos de estabilidade mecânica e selamento bacteriano. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12-15T10:59:49Z 2017-07-18 2017-07-18T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10284/6348 urn:tid:201911752 |
url |
http://hdl.handle.net/10284/6348 |
identifier_str_mv |
urn:tid:201911752 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833602075520401408 |