Mechanical stability of morse taper implant – abutment connection: a focused review

Bibliographic Details
Main Author: Al-Dujayli, Samantha
Publication Date: 2017
Format: Master thesis
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10284/6348
Summary: O objetivo principal deste estudo foi realizar uma revisão sistemática sobre a integridade mecânica das conexões cone Morse de implante em relação à presença de microgap e manutenção do torque. Uma ampla pesquisa eletrônica foi realizada nos bancos de dados PubMed, Embase e Medline com as palavras chaves: dental implant” e “dental abutment” e (“conical” ou “taper” ou “cone”). “removal torque” e “Morse Taper”, “torque loss” e “micro gap size” Estudos in vitro demonstraram que os pilares cônicos têm melhor desempenho, no que diz respeito ao selamento bacteriano e a manutenção do torque e estabilidade do pilar, do que os pilares não cônicos. Estudos in vivo mostraram que as taxas de sucesso e sobrevivência dos sistemas de implantes cone Morse comparadas aos outras, são quase comparáveis; porém os implantes com conexão cone Morse mostraram menor perda ossea marginal. Conclui-se , com esta revisão sistemática, que o uso de implantes com conexões cone Morse parece ser mais vantajoso, pois de mostraram ter melhor desempenho em termos de estabilidade mecânica e selamento bacteriano.
id RCAP_66be906a9355c81e7111d6f1734724d7
oai_identifier_str oai:bdigital.ufp.pt:10284/6348
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Mechanical stability of morse taper implant – abutment connection: a focused reviewSystematic reviewDental implantDental abutmentMorse taperImplant - abutment connectionMicrogap and seal performanceTorque maintenanceFatigue resistanceO objetivo principal deste estudo foi realizar uma revisão sistemática sobre a integridade mecânica das conexões cone Morse de implante em relação à presença de microgap e manutenção do torque. Uma ampla pesquisa eletrônica foi realizada nos bancos de dados PubMed, Embase e Medline com as palavras chaves: dental implant” e “dental abutment” e (“conical” ou “taper” ou “cone”). “removal torque” e “Morse Taper”, “torque loss” e “micro gap size” Estudos in vitro demonstraram que os pilares cônicos têm melhor desempenho, no que diz respeito ao selamento bacteriano e a manutenção do torque e estabilidade do pilar, do que os pilares não cônicos. Estudos in vivo mostraram que as taxas de sucesso e sobrevivência dos sistemas de implantes cone Morse comparadas aos outras, são quase comparáveis; porém os implantes com conexão cone Morse mostraram menor perda ossea marginal. Conclui-se , com esta revisão sistemática, que o uso de implantes com conexões cone Morse parece ser mais vantajoso, pois de mostraram ter melhor desempenho em termos de estabilidade mecânica e selamento bacteriano.Pereira, JorgeRepositório Institucional da Fernando PessoaAl-Dujayli, Samantha2017-12-15T10:59:49Z2017-07-182017-07-18T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10284/6348urn:tid:201911752enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-18T17:44:07Zoai:bdigital.ufp.pt:10284/6348Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T04:32:06.880331Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Mechanical stability of morse taper implant – abutment connection: a focused review
title Mechanical stability of morse taper implant – abutment connection: a focused review
spellingShingle Mechanical stability of morse taper implant – abutment connection: a focused review
Al-Dujayli, Samantha
Systematic review
Dental implant
Dental abutment
Morse taper
Implant - abutment connection
Microgap and seal performance
Torque maintenance
Fatigue resistance
title_short Mechanical stability of morse taper implant – abutment connection: a focused review
title_full Mechanical stability of morse taper implant – abutment connection: a focused review
title_fullStr Mechanical stability of morse taper implant – abutment connection: a focused review
title_full_unstemmed Mechanical stability of morse taper implant – abutment connection: a focused review
title_sort Mechanical stability of morse taper implant – abutment connection: a focused review
author Al-Dujayli, Samantha
author_facet Al-Dujayli, Samantha
author_role author
dc.contributor.none.fl_str_mv Pereira, Jorge
Repositório Institucional da Fernando Pessoa
dc.contributor.author.fl_str_mv Al-Dujayli, Samantha
dc.subject.por.fl_str_mv Systematic review
Dental implant
Dental abutment
Morse taper
Implant - abutment connection
Microgap and seal performance
Torque maintenance
Fatigue resistance
topic Systematic review
Dental implant
Dental abutment
Morse taper
Implant - abutment connection
Microgap and seal performance
Torque maintenance
Fatigue resistance
description O objetivo principal deste estudo foi realizar uma revisão sistemática sobre a integridade mecânica das conexões cone Morse de implante em relação à presença de microgap e manutenção do torque. Uma ampla pesquisa eletrônica foi realizada nos bancos de dados PubMed, Embase e Medline com as palavras chaves: dental implant” e “dental abutment” e (“conical” ou “taper” ou “cone”). “removal torque” e “Morse Taper”, “torque loss” e “micro gap size” Estudos in vitro demonstraram que os pilares cônicos têm melhor desempenho, no que diz respeito ao selamento bacteriano e a manutenção do torque e estabilidade do pilar, do que os pilares não cônicos. Estudos in vivo mostraram que as taxas de sucesso e sobrevivência dos sistemas de implantes cone Morse comparadas aos outras, são quase comparáveis; porém os implantes com conexão cone Morse mostraram menor perda ossea marginal. Conclui-se , com esta revisão sistemática, que o uso de implantes com conexões cone Morse parece ser mais vantajoso, pois de mostraram ter melhor desempenho em termos de estabilidade mecânica e selamento bacteriano.
publishDate 2017
dc.date.none.fl_str_mv 2017-12-15T10:59:49Z
2017-07-18
2017-07-18T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10284/6348
urn:tid:201911752
url http://hdl.handle.net/10284/6348
identifier_str_mv urn:tid:201911752
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602075520401408