Desenvolvimento de modelos de calibração multivariada em espectroscopia de infravermelho próximo para ácidos graxos em amostras de carne bovina

Detalhes bibliográficos
Ano de defesa: 2016
Autor(a) principal: Sousa, Jonas da Silva
Orientador(a): Nogueira, Ana Rita de Araújo lattes
Banca de defesa: Não Informado pela instituição
Tipo de documento: Dissertação
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade Federal de São Carlos
Câmpus São Carlos
Programa de Pós-Graduação: Programa de Pós-Graduação em Química - PPGQ
Departamento: Não Informado pela instituição
País: Não Informado pela instituição
Palavras-chave em Português:
Palavras-chave em Inglês:
Área do conhecimento CNPq:
Link de acesso: https://repositorio.ufscar.br/handle/20.500.14289/8622
Resumo: The Brazilian cattle have shown promise prominence in the international market compared to other commodities. It already knows the important role of fatty acids in the complimentarily of human nutrition. On the other hand, studies have linked the consumption of beef with increasing rate of diseases associated with high levels of "bad" cholesterol (LDL) in the blood. Because of these two aspects on the topic meat (nutritional value and human health), it is seen necessary to determine the levels oftrans fatty acids in meat. Among the methods for analysis of total lipids and lipid profile, stands out the extraction of fat and chromatography, respectively. In this project was proposed to develop multivariate calibration models for the analysis of total lipids and lipid profile with the use of near-infrared spectroscopy in beef samples which the levels were previously determined. Eighteen properties were analyzed, including: total lipids and myristic fatty acids, pentadecylic, palmitic, margaric, stearic, palmitoleic, oleic, elaidic, linoleic, α-linolenic and families of fatty acids with branched, saturated, monounsaturated (cis), conjugated linoleic (cis, trans), and omega 3 and 6 polyunsaturated. We used 127 bovine meat samples from the calibration steps and internal validation (2/3 to 1/3 calibration and validation for internal and 32 external validation samples. We used the PLSR method for the construction of multivariate models. Flesh spectra were extended from 1111 to 1937, and from 2016 to 2500 nm regions, and regions concerning water and noise judged as interfering in the calibration process were removed during the models construction. We evaluated the performance of the models based on the applied pre-treatments (smoothing, first derivative Savitzky-Golay, SNV), the number of latent variables, consistency, SEC, SEP and determination coefficients (R2 cal/val). The models chosen as having better predictive capacity were those of total lipids, myristic acid, palmitic acid, margárico and saturated fatty acids, demonstrating that the NIRS has a high potential for the quantification of lipid constituents of the beef.