Export Ready — 

Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal

Bibliographic Details
Main Author: Maranzatto Junior, Antonio Roberto
Publication Date: 2017
Format: Bachelor thesis
Language: por
Source: Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
Download full: http://repositorio.utfpr.edu.br/jspui/handle/1/12061
Summary: Removing nutrients from sanitary sewage is still a major challenge. Conventional sewage treatment systems do not attenuate the high load of nutrients such as nitrogen (N) and phosphorus (P), and the usual methods of removal require high investment for installation and operation. Dumping at high concentrations in water bodies causes serious consequences such as eutrophication and, in groundwater, concern is with nitrate, which contaminates drinking water and can cause public health problems such as blue baby syndrome (methemoglobinemia). The objective of this study was to evaluate the efficiency of nutrient removal in an experimental lagoon of Lemnas (Landoltia punctata), on a bench scale, as a post-treatment unit of sanitary sewage coupled to a Horizontal Flow Built Wetland. The effluent used came from a University Restaurant. The total removal efficiency of KTN and ammoniacal nitrogen (NH4 +) was 77.27% and 56.22%, respectively, whereas in the Lemnas lagoon the removal was 48.79% and 37.67%. The average efficiency of COD removal was 86.19% and 31.87%. From the results it was possible to verify that the association of the Lemnas lagoon was shown as a viable alternative to compose the constructed Wetland System considered.
id UTFPR-12_b019b81ac533b4335f70d581b2bde476
oai_identifier_str oai:repositorio.utfpr.edu.br:1/12061
network_acronym_str UTFPR-12
network_name_str Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
repository_id_str
spelling Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontalLemnaceae lagoon employed in post-treatment of the effluent of a wetland constructed of horizontal flowLagoas de estabilizaçãoÁguas residuais - PurificaçãoAlagadiçosSewage LagoonsSewage - PurificationWetlandsCNPQ::ENGENHARIAS::ENGENHARIA SANITARIARemoving nutrients from sanitary sewage is still a major challenge. Conventional sewage treatment systems do not attenuate the high load of nutrients such as nitrogen (N) and phosphorus (P), and the usual methods of removal require high investment for installation and operation. Dumping at high concentrations in water bodies causes serious consequences such as eutrophication and, in groundwater, concern is with nitrate, which contaminates drinking water and can cause public health problems such as blue baby syndrome (methemoglobinemia). The objective of this study was to evaluate the efficiency of nutrient removal in an experimental lagoon of Lemnas (Landoltia punctata), on a bench scale, as a post-treatment unit of sanitary sewage coupled to a Horizontal Flow Built Wetland. The effluent used came from a University Restaurant. The total removal efficiency of KTN and ammoniacal nitrogen (NH4 +) was 77.27% and 56.22%, respectively, whereas in the Lemnas lagoon the removal was 48.79% and 37.67%. The average efficiency of COD removal was 86.19% and 31.87%. From the results it was possible to verify that the association of the Lemnas lagoon was shown as a viable alternative to compose the constructed Wetland System considered.A remoção de nutrientes do esgoto sanitário ainda é um grande desafio. Os sistemas de tratamento de esgoto convencionais não atenuam a alta carga de nutrientes como nitrogênio (N) e Fósforo (P), e os métodos usuais de remoção demandam alto investimento para instalação e operação. O despejo desses nutrientes nos corpos hídricos causam consequências graves como a eutrofização e, nas águas subterrâneas, a preocupação é com o nitrato, que contamina as águas de abastecimento e pode causar problemas de saúde pública como a síndrome do bebê azul (metemoglobinemia). Diante disso este estudo teve como objetivo avaliar a eficiência na remoção de nutrientes em uma lagoa experimental de Lemnas (Landoltia punctata), em escala de bancada, como unidade de pós tratamento de esgoto produzido por um Wetland Construído de Fluxo horizontal (WCFH). O WCFH tratava esgoto oriundo de um Restaurante Universitário do Campus de Londrina da UTFPR. A eficiência de remoção média total de NTK e nitrogênio amoniacal (NH4+) foram de 77,27% e 56,22% respectivamente, já na lagoa de Lemnas a remoção foi de 48,79% e 37,67%. A eficiência média de remoção de DQO foi de 86,19% e 31,87%. A partir dos resultados foi possível constatar que a associação da lagoa de Lemnas se mostrou como alternativa viável para compor sistema de polimento do Sistema Wetland construído considerado.Universidade Tecnológica Federal do ParanáLondrinaBrasilEngenharia ambientalUTFPRCarvalho Junior, Orlando deFazolo, AzadirConstanzi, Ricardo NagamineCarvalho Junior, Orlando deMaranzatto Junior, Antonio Roberto2020-11-16T10:55:24Z2020-11-16T10:55:24Z2017-11-29info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfMARANZATTO JUNIOR, Antonio Roberto. Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal. 2017. 77 f. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Londrina, 2017.http://repositorio.utfpr.edu.br/jspui/handle/1/12061porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))instname:Universidade Tecnológica Federal do Paraná (UTFPR)instacron:UTFPR2020-11-16T10:55:24Zoai:repositorio.utfpr.edu.br:1/12061Repositório InstitucionalPUBhttp://repositorio.utfpr.edu.br:8080/oai/requestriut@utfpr.edu.bropendoar:2020-11-16T10:55:24Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) - Universidade Tecnológica Federal do Paraná (UTFPR)false
dc.title.none.fl_str_mv Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
Lemnaceae lagoon employed in post-treatment of the effluent of a wetland constructed of horizontal flow
title Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
spellingShingle Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
Maranzatto Junior, Antonio Roberto
Lagoas de estabilização
Águas residuais - Purificação
Alagadiços
Sewage Lagoons
Sewage - Purification
Wetlands
CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA
title_short Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
title_full Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
title_fullStr Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
title_full_unstemmed Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
title_sort Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal
author Maranzatto Junior, Antonio Roberto
author_facet Maranzatto Junior, Antonio Roberto
author_role author
dc.contributor.none.fl_str_mv Carvalho Junior, Orlando de
Fazolo, Azadir
Constanzi, Ricardo Nagamine
Carvalho Junior, Orlando de
dc.contributor.author.fl_str_mv Maranzatto Junior, Antonio Roberto
dc.subject.por.fl_str_mv Lagoas de estabilização
Águas residuais - Purificação
Alagadiços
Sewage Lagoons
Sewage - Purification
Wetlands
CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA
topic Lagoas de estabilização
Águas residuais - Purificação
Alagadiços
Sewage Lagoons
Sewage - Purification
Wetlands
CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA
description Removing nutrients from sanitary sewage is still a major challenge. Conventional sewage treatment systems do not attenuate the high load of nutrients such as nitrogen (N) and phosphorus (P), and the usual methods of removal require high investment for installation and operation. Dumping at high concentrations in water bodies causes serious consequences such as eutrophication and, in groundwater, concern is with nitrate, which contaminates drinking water and can cause public health problems such as blue baby syndrome (methemoglobinemia). The objective of this study was to evaluate the efficiency of nutrient removal in an experimental lagoon of Lemnas (Landoltia punctata), on a bench scale, as a post-treatment unit of sanitary sewage coupled to a Horizontal Flow Built Wetland. The effluent used came from a University Restaurant. The total removal efficiency of KTN and ammoniacal nitrogen (NH4 +) was 77.27% and 56.22%, respectively, whereas in the Lemnas lagoon the removal was 48.79% and 37.67%. The average efficiency of COD removal was 86.19% and 31.87%. From the results it was possible to verify that the association of the Lemnas lagoon was shown as a viable alternative to compose the constructed Wetland System considered.
publishDate 2017
dc.date.none.fl_str_mv 2017-11-29
2020-11-16T10:55:24Z
2020-11-16T10:55:24Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv MARANZATTO JUNIOR, Antonio Roberto. Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal. 2017. 77 f. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Londrina, 2017.
http://repositorio.utfpr.edu.br/jspui/handle/1/12061
identifier_str_mv MARANZATTO JUNIOR, Antonio Roberto. Lagoa de lemnáceas empregada no pós tratamento do efluente de um wetland construido de fluxo horizontal. 2017. 77 f. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Londrina, 2017.
url http://repositorio.utfpr.edu.br/jspui/handle/1/12061
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Tecnológica Federal do Paraná
Londrina
Brasil
Engenharia ambiental
UTFPR
publisher.none.fl_str_mv Universidade Tecnológica Federal do Paraná
Londrina
Brasil
Engenharia ambiental
UTFPR
dc.source.none.fl_str_mv reponame:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
instname:Universidade Tecnológica Federal do Paraná (UTFPR)
instacron:UTFPR
instname_str Universidade Tecnológica Federal do Paraná (UTFPR)
instacron_str UTFPR
institution UTFPR
reponame_str Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
collection Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
repository.name.fl_str_mv Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) - Universidade Tecnológica Federal do Paraná (UTFPR)
repository.mail.fl_str_mv riut@utfpr.edu.br
_version_ 1834836400842735616