Estimulador galvânico vestibular para fMRI
Main Author: | |
---|---|
Publication Date: | 2012 |
Format: | Master thesis |
Language: | por |
Source: | Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) |
Download full: | http://repositorio.utfpr.edu.br/jspui/handle/1/406 |
Summary: | This work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system. |
id |
UTFPR-12_226bd5505c3fe783365b3e1be5d6c96b |
---|---|
oai_identifier_str |
oai:repositorio.utfpr.edu.br:1/406 |
network_acronym_str |
UTFPR-12 |
network_name_str |
Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) |
repository_id_str |
|
spelling |
Estimulador galvânico vestibular para fMRIVestíbulos (Ouvidos)Imagens e fantasmas (Radiologia)Aparelho vestibularFibras ópticasInstrumentos e aparelhos médicosEngenharia elétricaVestibular apparatusPhantoms (Radiology)Optical fibersMedical instruments and apparatusElectric engineeringThis work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system.Este trabalho apresenta o desenvolvimento de um estimulador galvânico vestibular para ser usado em experimentos de imageamento por ressonância magnética funcional (fMRI). Em experiências de fMRI é necessário a produção de estímulos somatossensoriais no paciente. Os estímulos devem ser sincronizados com a sequência de pulsos da fMRI. O estimulador foi dividido em circuitos analógicos (colocados dentro da sala do magneto) e circuitos digitais (sala de comando do sistema de MRI). A comunicação entre os circuitos é feita através de fibra óptica. Experimentos de fMRI realizados com voluntários demonstraram que o estimulador proposto é capaz de manter a sincronização com sistema de fMRI e pode ser usado para localizar as áreas do cérebro que são ativados pelo sistema vestibular.Universidade Tecnológica Federal do ParanáCuritibaPrograma de Pós-Graduação em Engenharia Elétrica e Informática IndustrialGamba, Humberto RemigioManczak, Tiago2013-02-08T15:43:01Z2013-02-08T15:43:01Z2012-07-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfMANCZAK, Tiago. Estimulador galvânico vestibular para fMRI. 2012. 77 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) – Universidade Tecnológica Federal do Paraná, Curitiba, 2012.http://repositorio.utfpr.edu.br/jspui/handle/1/406porreponame:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))instname:Universidade Tecnológica Federal do Paraná (UTFPR)instacron:UTFPRinfo:eu-repo/semantics/openAccess2015-05-19T21:03:48Zoai:repositorio.utfpr.edu.br:1/406Repositório InstitucionalPUBhttp://repositorio.utfpr.edu.br:8080/oai/requestriut@utfpr.edu.bropendoar:2015-05-19T21:03:48Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) - Universidade Tecnológica Federal do Paraná (UTFPR)false |
dc.title.none.fl_str_mv |
Estimulador galvânico vestibular para fMRI |
title |
Estimulador galvânico vestibular para fMRI |
spellingShingle |
Estimulador galvânico vestibular para fMRI Manczak, Tiago Vestíbulos (Ouvidos) Imagens e fantasmas (Radiologia) Aparelho vestibular Fibras ópticas Instrumentos e aparelhos médicos Engenharia elétrica Vestibular apparatus Phantoms (Radiology) Optical fibers Medical instruments and apparatus Electric engineering |
title_short |
Estimulador galvânico vestibular para fMRI |
title_full |
Estimulador galvânico vestibular para fMRI |
title_fullStr |
Estimulador galvânico vestibular para fMRI |
title_full_unstemmed |
Estimulador galvânico vestibular para fMRI |
title_sort |
Estimulador galvânico vestibular para fMRI |
author |
Manczak, Tiago |
author_facet |
Manczak, Tiago |
author_role |
author |
dc.contributor.none.fl_str_mv |
Gamba, Humberto Remigio |
dc.contributor.author.fl_str_mv |
Manczak, Tiago |
dc.subject.por.fl_str_mv |
Vestíbulos (Ouvidos) Imagens e fantasmas (Radiologia) Aparelho vestibular Fibras ópticas Instrumentos e aparelhos médicos Engenharia elétrica Vestibular apparatus Phantoms (Radiology) Optical fibers Medical instruments and apparatus Electric engineering |
topic |
Vestíbulos (Ouvidos) Imagens e fantasmas (Radiologia) Aparelho vestibular Fibras ópticas Instrumentos e aparelhos médicos Engenharia elétrica Vestibular apparatus Phantoms (Radiology) Optical fibers Medical instruments and apparatus Electric engineering |
description |
This work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-07-30 2013-02-08T15:43:01Z 2013-02-08T15:43:01Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
MANCZAK, Tiago. Estimulador galvânico vestibular para fMRI. 2012. 77 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) – Universidade Tecnológica Federal do Paraná, Curitiba, 2012. http://repositorio.utfpr.edu.br/jspui/handle/1/406 |
identifier_str_mv |
MANCZAK, Tiago. Estimulador galvânico vestibular para fMRI. 2012. 77 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) – Universidade Tecnológica Federal do Paraná, Curitiba, 2012. |
url |
http://repositorio.utfpr.edu.br/jspui/handle/1/406 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Tecnológica Federal do Paraná Curitiba Programa de Pós-Graduação em Engenharia Elétrica e Informática Industrial |
publisher.none.fl_str_mv |
Universidade Tecnológica Federal do Paraná Curitiba Programa de Pós-Graduação em Engenharia Elétrica e Informática Industrial |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) instname:Universidade Tecnológica Federal do Paraná (UTFPR) instacron:UTFPR |
instname_str |
Universidade Tecnológica Federal do Paraná (UTFPR) |
instacron_str |
UTFPR |
institution |
UTFPR |
reponame_str |
Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) |
collection |
Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) |
repository.name.fl_str_mv |
Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) - Universidade Tecnológica Federal do Paraná (UTFPR) |
repository.mail.fl_str_mv |
riut@utfpr.edu.br |
_version_ |
1834836338675810304 |