Export Ready — 

Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m

Bibliographic Details
Main Author: Monteiro, Elisiane de Godoy
Publication Date: 2012
Format: Master thesis
Language: por
Source: Biblioteca Digital de Teses e Dissertações da USP
Download full: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06032013-134516/
Summary: Os radiofármacos são substâncias que possuem radioisótopos em sua composição. Cerca de 95% dos procedimentos realizados em medicina nuclear faz o uso de radiofármacos com finalidade diagnóstica, sendo os reagentes liofilizados (RL) marcados com Tecnécio-99 meta estável (99mTc), obtido a partir de um gerador de 99Mo/99mTc, os mais utilizados. O controle de qualidade representa o conjunto de ensaios a serem realizados para certificar que o produto é adequado ao propósito. Um aspecto importante a ser avaliado nos radiofármacos de 99mTc é a pureza radioquímica (% PRq) para quantificação de pertecnetato livre (99mTcO4 -) e tecnécio coloidal (99mTcO2), principalmente por cromatografia em papel (CP), em camada delgada (CCD) e cromatografia líquida de alta eficiência (CLAE). O objetivo deste trabalho foi realizar a comparação das metodologias de controle radioquímico de RL marcados com 99mTc descritas nas farmacopéias americana (FA) e europeia (FE) com aquelas utilizadas no IPEN. O eluído de 99mTcO4 e os RL: DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH e Sn Coloidal foram provenientes do IPEN-CNEN/SP. Foram utilizados os suportes cromatográficos TLC-celulose, TLC-SG,TLC-SG fase reversa, HPTLC-celulose e HPTLC-SG da Merck e ITLC-SG da Pall Corporation, W1MM, W3MM, W17M e W31ET da Whatman. A contagem da radioatividade foi feita em contador gama Perkin Elmer modelo Cobra D-5002. A marcação dos RL foi feita de modo a obter concentração radioativa de 55,0 MBq mL-1 (1,5 mCi mL-1). Foram determinadas as %99mTcO4 -, %99mTcO2 e % PRq até 4 horas de marcação. Dos 11 RL, apenas EC e GHA não possuem método de controle radioquímico na FA e FE. Na FA e/ou na FE, os métodos para DTPA, MDP, PIRO, SAH e Sn Coloidal utilizam ITLC-SG; no IPEN, este suporte cromatográfico é utilizado em DISIDA, EC, ECD, GHA, PIRO, MIBI e SAH. Devido à descontinuidade na fabricação de ITLC-SG (recomendado em 40, 70 e 41% das metodologias da FA, FE e IPEN, respectivamente), foi necessário buscar alternativas para sua substituição no controle radioquímico, avaliando-se suportes do tipo HPTLC (celulose e sílica gel) e Whatman (com diferenças de espessura e fluxo de corrida). Os resultados de % PRq determinada pelos métodos descritos na FA, FE, IPEN e os demais sistemas avaliados que apresentaram coeficiente de variação menor que 5% não foi considerada diferença significativa entre os métodos. Os sistemas cromatográficos avaliados neste trabalho podem ser utilizados em substituição ao suporte ITLC-SG. O HPTLC-celulose foi o suporte que apresentou tempo de análise, perfil cromatográfico e custo semelhante ao ITLC-SG, tornando-o um dos suportes mais indicados a ser utilizado como alternativa ao ITLC-SG nos 11 RL avaliados.
id USP_dccc1acfaea526af0da8d84d2644e90b
oai_identifier_str oai:teses.usp.br:tde-06032013-134516
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99mComparison study among methodologies of planar chromatography for radiochemical control of Tecnécio-99m radiopharmaceuticalsmedicina nuclearnuclear medicinepureza radioquímicaradiochemical purityradiofármacoradiopharmaceuticalsOs radiofármacos são substâncias que possuem radioisótopos em sua composição. Cerca de 95% dos procedimentos realizados em medicina nuclear faz o uso de radiofármacos com finalidade diagnóstica, sendo os reagentes liofilizados (RL) marcados com Tecnécio-99 meta estável (99mTc), obtido a partir de um gerador de 99Mo/99mTc, os mais utilizados. O controle de qualidade representa o conjunto de ensaios a serem realizados para certificar que o produto é adequado ao propósito. Um aspecto importante a ser avaliado nos radiofármacos de 99mTc é a pureza radioquímica (% PRq) para quantificação de pertecnetato livre (99mTcO4 -) e tecnécio coloidal (99mTcO2), principalmente por cromatografia em papel (CP), em camada delgada (CCD) e cromatografia líquida de alta eficiência (CLAE). O objetivo deste trabalho foi realizar a comparação das metodologias de controle radioquímico de RL marcados com 99mTc descritas nas farmacopéias americana (FA) e europeia (FE) com aquelas utilizadas no IPEN. O eluído de 99mTcO4 e os RL: DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH e Sn Coloidal foram provenientes do IPEN-CNEN/SP. Foram utilizados os suportes cromatográficos TLC-celulose, TLC-SG,TLC-SG fase reversa, HPTLC-celulose e HPTLC-SG da Merck e ITLC-SG da Pall Corporation, W1MM, W3MM, W17M e W31ET da Whatman. A contagem da radioatividade foi feita em contador gama Perkin Elmer modelo Cobra D-5002. A marcação dos RL foi feita de modo a obter concentração radioativa de 55,0 MBq mL-1 (1,5 mCi mL-1). Foram determinadas as %99mTcO4 -, %99mTcO2 e % PRq até 4 horas de marcação. Dos 11 RL, apenas EC e GHA não possuem método de controle radioquímico na FA e FE. Na FA e/ou na FE, os métodos para DTPA, MDP, PIRO, SAH e Sn Coloidal utilizam ITLC-SG; no IPEN, este suporte cromatográfico é utilizado em DISIDA, EC, ECD, GHA, PIRO, MIBI e SAH. Devido à descontinuidade na fabricação de ITLC-SG (recomendado em 40, 70 e 41% das metodologias da FA, FE e IPEN, respectivamente), foi necessário buscar alternativas para sua substituição no controle radioquímico, avaliando-se suportes do tipo HPTLC (celulose e sílica gel) e Whatman (com diferenças de espessura e fluxo de corrida). Os resultados de % PRq determinada pelos métodos descritos na FA, FE, IPEN e os demais sistemas avaliados que apresentaram coeficiente de variação menor que 5% não foi considerada diferença significativa entre os métodos. Os sistemas cromatográficos avaliados neste trabalho podem ser utilizados em substituição ao suporte ITLC-SG. O HPTLC-celulose foi o suporte que apresentou tempo de análise, perfil cromatográfico e custo semelhante ao ITLC-SG, tornando-o um dos suportes mais indicados a ser utilizado como alternativa ao ITLC-SG nos 11 RL avaliados.Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic pruposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m (99mTc), obtained from 99Mo/99mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99mTc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate (99mTcO4 -) and technetium colloidal (99mTcO2) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perfom the comparison among the radiochemical control methodologies of LR labeled with 99mTc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99mTcO4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-celulose, TLC-SG,TLC-SG reverse phase, HPTLC-celulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL-1 (1,5 mCi mL-1) of final radioactive concentration. The %99mTcO4 -, %99mTcO2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control, comparing with HPTLC (cellulose and silica gel) and Whatman plates (with thickness and flow rate differences). The % RqP results determined by the methods described in USP, EP, IPEN and the methods evaluated in this work presented coefficient of variation less than 5%, and it was not considered a significant value among the methods. Some chromatographic systems evaluated in this work can be used as replacement to the ITLC-SG plate. HPTLC-cellulose was the plate that presented time of analysis chromatography profile and cost similar to ITLC-SG, making it one of the most indicated to replace ITLC-SG, in 11 LR evaluated.Biblioteca Digitais de Teses e Dissertações da USPMatsuda, Margareth Mie NakamuraMonteiro, Elisiane de Godoy2012-04-26info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/85/85131/tde-06032013-134516/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesspor2016-07-28T16:10:35Zoai:teses.usp.br:tde-06032013-134516Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212016-07-28T16:10:35Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
Comparison study among methodologies of planar chromatography for radiochemical control of Tecnécio-99m radiopharmaceuticals
title Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
spellingShingle Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
Monteiro, Elisiane de Godoy
medicina nuclear
nuclear medicine
pureza radioquímica
radiochemical purity
radiofármaco
radiopharmaceuticals
title_short Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
title_full Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
title_fullStr Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
title_full_unstemmed Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
title_sort Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m
author Monteiro, Elisiane de Godoy
author_facet Monteiro, Elisiane de Godoy
author_role author
dc.contributor.none.fl_str_mv Matsuda, Margareth Mie Nakamura
dc.contributor.author.fl_str_mv Monteiro, Elisiane de Godoy
dc.subject.por.fl_str_mv medicina nuclear
nuclear medicine
pureza radioquímica
radiochemical purity
radiofármaco
radiopharmaceuticals
topic medicina nuclear
nuclear medicine
pureza radioquímica
radiochemical purity
radiofármaco
radiopharmaceuticals
description Os radiofármacos são substâncias que possuem radioisótopos em sua composição. Cerca de 95% dos procedimentos realizados em medicina nuclear faz o uso de radiofármacos com finalidade diagnóstica, sendo os reagentes liofilizados (RL) marcados com Tecnécio-99 meta estável (99mTc), obtido a partir de um gerador de 99Mo/99mTc, os mais utilizados. O controle de qualidade representa o conjunto de ensaios a serem realizados para certificar que o produto é adequado ao propósito. Um aspecto importante a ser avaliado nos radiofármacos de 99mTc é a pureza radioquímica (% PRq) para quantificação de pertecnetato livre (99mTcO4 -) e tecnécio coloidal (99mTcO2), principalmente por cromatografia em papel (CP), em camada delgada (CCD) e cromatografia líquida de alta eficiência (CLAE). O objetivo deste trabalho foi realizar a comparação das metodologias de controle radioquímico de RL marcados com 99mTc descritas nas farmacopéias americana (FA) e europeia (FE) com aquelas utilizadas no IPEN. O eluído de 99mTcO4 e os RL: DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH e Sn Coloidal foram provenientes do IPEN-CNEN/SP. Foram utilizados os suportes cromatográficos TLC-celulose, TLC-SG,TLC-SG fase reversa, HPTLC-celulose e HPTLC-SG da Merck e ITLC-SG da Pall Corporation, W1MM, W3MM, W17M e W31ET da Whatman. A contagem da radioatividade foi feita em contador gama Perkin Elmer modelo Cobra D-5002. A marcação dos RL foi feita de modo a obter concentração radioativa de 55,0 MBq mL-1 (1,5 mCi mL-1). Foram determinadas as %99mTcO4 -, %99mTcO2 e % PRq até 4 horas de marcação. Dos 11 RL, apenas EC e GHA não possuem método de controle radioquímico na FA e FE. Na FA e/ou na FE, os métodos para DTPA, MDP, PIRO, SAH e Sn Coloidal utilizam ITLC-SG; no IPEN, este suporte cromatográfico é utilizado em DISIDA, EC, ECD, GHA, PIRO, MIBI e SAH. Devido à descontinuidade na fabricação de ITLC-SG (recomendado em 40, 70 e 41% das metodologias da FA, FE e IPEN, respectivamente), foi necessário buscar alternativas para sua substituição no controle radioquímico, avaliando-se suportes do tipo HPTLC (celulose e sílica gel) e Whatman (com diferenças de espessura e fluxo de corrida). Os resultados de % PRq determinada pelos métodos descritos na FA, FE, IPEN e os demais sistemas avaliados que apresentaram coeficiente de variação menor que 5% não foi considerada diferença significativa entre os métodos. Os sistemas cromatográficos avaliados neste trabalho podem ser utilizados em substituição ao suporte ITLC-SG. O HPTLC-celulose foi o suporte que apresentou tempo de análise, perfil cromatográfico e custo semelhante ao ITLC-SG, tornando-o um dos suportes mais indicados a ser utilizado como alternativa ao ITLC-SG nos 11 RL avaliados.
publishDate 2012
dc.date.none.fl_str_mv 2012-04-26
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06032013-134516/
url http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06032013-134516/
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv
dc.rights.driver.fl_str_mv Liberar o conteúdo para acesso público.
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Liberar o conteúdo para acesso público.
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv
dc.publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
dc.source.none.fl_str_mv
reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1826318513255481344