Demanda energética em diferentes manejos de solo e híbridos de milho

Bibliographic Details
Main Author: Riquetti, Neilor Bugoni [UNESP]
Publication Date: 2012
Other Authors: Benez, Sérgio Hugo [UNESP], Silva, Paulo Roberto Arbex [UNESP]
Format: Article
Language: por
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.17224/EnergAgric.2012v27n2p76-85
http://hdl.handle.net/11449/137449
Summary: This study aimed to account the energy balance of six different farming systems: CMT (minimum tillage with transgenic corn); CMNT (minimum tillage with non-transgenic corn); PCT (conventional tillage with transgenic corn); PCNT (conventional tillage with non-transgenic corn); PDT (no-tillage system with transgenic corn) and PDNT (no-tillage system with non-transgenic corn). The study was carried out at the Experimental Farm Lageado FCA/Unesp, Botucatu - SP. The energy balance was performed by subtracting the total energy inputs by the total energy output. Energy efficiency was calculated by dividing the total energy output by the total energy inputs. The total values ​​of energy inputs and outputs were expressed in MJ.ha-1 (mega joules per hectare). To calculate the energy inputs were accounted the fuel consumption and lubricants, depreciation energy of machinery and implements, manpower and agricultural inputs. The energy outputs were calculated according to the maize yield. The result shows that the system PDT was the system that had better energy efficiency and the system that had the lowest efficiency was the PCT system. The system with lower energy demand was the PDT and the greatest demand was PCNT.
id UNSP_f57b3a9c7662b767b8af2fb8aa20d546
oai_identifier_str oai:repositorio.unesp.br:11449/137449
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Demanda energética em diferentes manejos de solo e híbridos de milhoEnergy demand in different soil tillage and corn hybridsMinimum tillageConventional tillageNo tillageCultivo mínimoPreparo convencionalPlantio diretoThis study aimed to account the energy balance of six different farming systems: CMT (minimum tillage with transgenic corn); CMNT (minimum tillage with non-transgenic corn); PCT (conventional tillage with transgenic corn); PCNT (conventional tillage with non-transgenic corn); PDT (no-tillage system with transgenic corn) and PDNT (no-tillage system with non-transgenic corn). The study was carried out at the Experimental Farm Lageado FCA/Unesp, Botucatu - SP. The energy balance was performed by subtracting the total energy inputs by the total energy output. Energy efficiency was calculated by dividing the total energy output by the total energy inputs. The total values ​​of energy inputs and outputs were expressed in MJ.ha-1 (mega joules per hectare). To calculate the energy inputs were accounted the fuel consumption and lubricants, depreciation energy of machinery and implements, manpower and agricultural inputs. The energy outputs were calculated according to the maize yield. The result shows that the system PDT was the system that had better energy efficiency and the system that had the lowest efficiency was the PCT system. The system with lower energy demand was the PDT and the greatest demand was PCNT.O presente trabalho teve por objetivo contabilizar o balanço energético de seis diferentes sistemas de produção: CMT (cultivo mínimo com milho transgênico); CMNT (cultivo mínimo com milho não transgênico); PCT (preparo convencional com milho transgênico); PCNT (preparo convencional com milho não transgênico); PDT (sistema de plantio direto com milho transgênico) e PDNT (sistema de plantio direto com milho não transgênico). O estudo foi realizado na fazenda Experimental Lageado pertencente à Faculdade de Ciências Agronômicas da Unesp Campus de Botucatu - SP. O balanço energético foi realizado subtraindo-se o total de entradas de energia pelo total de saídas de energia. A eficiência energética foi calculada dividindo-se o total de saídas de energia pelo total de entradas de energia. Os valores totais de entradas e saídas de energia foram expressos em MJ ha-1 (megajoule por hectare). Para o cálculo das entradas foram contabilizadas as energias referentes ao consumo de combustível e lubrificantes, depreciação energética das máquinas e implementos,mão-de-obra e insumos agrícolas. As saídas de energia foram calculadas em função da produtividade da cultura do milho.Os resultados obtidos mostram que o sistema de PDT foi o sistema que apresentou uma melhor eficiência energética e o sistema que apresentou a menor eficiência foi o sistema de PCT. O sistema de menor demanda energética foi o PDT e o de maior demanda foi o PCNT.Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Engenharia Rural, Faculdade de Ciências Agronômicas de Botucatu, Botucatu, SP, BrasilUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Engenharia Rural, Faculdade de Ciências Agronômicas de Botucatu, Botucatu, SP, BrasilUniversidade Estadual Paulista (Unesp)Riquetti, Neilor Bugoni [UNESP]Benez, Sérgio Hugo [UNESP]Silva, Paulo Roberto Arbex [UNESP]2016-04-01T18:45:42Z2016-04-01T18:45:42Z2012info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article76-85application/pdfhttp://dx.doi.org/10.17224/EnergAgric.2012v27n2p76-85Energia na Agricultura, v. 27, n. 2, p. 76-85, 2012.1808-8759http://hdl.handle.net/11449/13744910.17224/EnergAgric.2012v27n2p76-85ISSN1808-8759-2012-27-02-76-85.pdf99943996673502490000-0003-2737-5788Currículo Lattesreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporEnergia na Agriculturainfo:eu-repo/semantics/openAccess2024-04-30T14:02:37Zoai:repositorio.unesp.br:11449/137449Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-04-30T14:02:37Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Demanda energética em diferentes manejos de solo e híbridos de milho
Energy demand in different soil tillage and corn hybrids
title Demanda energética em diferentes manejos de solo e híbridos de milho
spellingShingle Demanda energética em diferentes manejos de solo e híbridos de milho
Riquetti, Neilor Bugoni [UNESP]
Minimum tillage
Conventional tillage
No tillage
Cultivo mínimo
Preparo convencional
Plantio direto
title_short Demanda energética em diferentes manejos de solo e híbridos de milho
title_full Demanda energética em diferentes manejos de solo e híbridos de milho
title_fullStr Demanda energética em diferentes manejos de solo e híbridos de milho
title_full_unstemmed Demanda energética em diferentes manejos de solo e híbridos de milho
title_sort Demanda energética em diferentes manejos de solo e híbridos de milho
author Riquetti, Neilor Bugoni [UNESP]
author_facet Riquetti, Neilor Bugoni [UNESP]
Benez, Sérgio Hugo [UNESP]
Silva, Paulo Roberto Arbex [UNESP]
author_role author
author2 Benez, Sérgio Hugo [UNESP]
Silva, Paulo Roberto Arbex [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Riquetti, Neilor Bugoni [UNESP]
Benez, Sérgio Hugo [UNESP]
Silva, Paulo Roberto Arbex [UNESP]
dc.subject.por.fl_str_mv Minimum tillage
Conventional tillage
No tillage
Cultivo mínimo
Preparo convencional
Plantio direto
topic Minimum tillage
Conventional tillage
No tillage
Cultivo mínimo
Preparo convencional
Plantio direto
description This study aimed to account the energy balance of six different farming systems: CMT (minimum tillage with transgenic corn); CMNT (minimum tillage with non-transgenic corn); PCT (conventional tillage with transgenic corn); PCNT (conventional tillage with non-transgenic corn); PDT (no-tillage system with transgenic corn) and PDNT (no-tillage system with non-transgenic corn). The study was carried out at the Experimental Farm Lageado FCA/Unesp, Botucatu - SP. The energy balance was performed by subtracting the total energy inputs by the total energy output. Energy efficiency was calculated by dividing the total energy output by the total energy inputs. The total values ​​of energy inputs and outputs were expressed in MJ.ha-1 (mega joules per hectare). To calculate the energy inputs were accounted the fuel consumption and lubricants, depreciation energy of machinery and implements, manpower and agricultural inputs. The energy outputs were calculated according to the maize yield. The result shows that the system PDT was the system that had better energy efficiency and the system that had the lowest efficiency was the PCT system. The system with lower energy demand was the PDT and the greatest demand was PCNT.
publishDate 2012
dc.date.none.fl_str_mv 2012
2016-04-01T18:45:42Z
2016-04-01T18:45:42Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.17224/EnergAgric.2012v27n2p76-85
Energia na Agricultura, v. 27, n. 2, p. 76-85, 2012.
1808-8759
http://hdl.handle.net/11449/137449
10.17224/EnergAgric.2012v27n2p76-85
ISSN1808-8759-2012-27-02-76-85.pdf
9994399667350249
0000-0003-2737-5788
url http://dx.doi.org/10.17224/EnergAgric.2012v27n2p76-85
http://hdl.handle.net/11449/137449
identifier_str_mv Energia na Agricultura, v. 27, n. 2, p. 76-85, 2012.
1808-8759
10.17224/EnergAgric.2012v27n2p76-85
ISSN1808-8759-2012-27-02-76-85.pdf
9994399667350249
0000-0003-2737-5788
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv Energia na Agricultura
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 76-85
application/pdf
dc.source.none.fl_str_mv Currículo Lattes
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834484681676947456