Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes

Bibliographic Details
Main Author: Inazaki, Thelma Helena [UNESP]
Publication Date: 2004
Other Authors: Pião, Antonio Carlos Simões [UNESP], Bidoia, Ederio Dino [UNESP]
Format: Article
Language: eng
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.1590/S1516-89132004000600018
http://hdl.handle.net/11449/20088
Summary: O presente trabalho apresenta os resultados dos tratamentos eletrolíticos (05; 15; 30; 45 e 60 min) no efluente simulado com o composto Flexzone 3P, utilizando-se eletrodos de Ti/TiRuO2, sob 0,025 A cm-2. Após as eletrólises, foram feitas análises de pH, condutividade, espectrofotometria no UV-vis, análise por cromatografia gasosa, ensaios de toxicidade utilizando Saccharomyces cerevisiae e ensaio de respirometria de Bartha. O pH dos efluentes foi diminuindo à medida que aumentou- se o tempo de eletrólise, ao contrário da condutividade, a qual apresentou pequeno aumento. Verificou-se que após 60 min de tratamento foi obtida diminuição da concentração do composto Flexzone 3P em 65,1%. Analisando-se os espectros de UV-vis e cromatogramas do efluente após realização do tratamento eletrolítico, concluiu-se que ocorreram oxidações e transformações de funções orgânicas do composto, durante os tratamentos. Após a realização do tratamento eletrolítico, o efluente simulado apresentou diminuição da toxicidade a S. cerevisiae, após 5 min de eletrólise. O tempo de eletrólise de 5 min foi o que apresentou melhor resultado de biodegradação do que os demais períodos de tratamento, no ensaio de respirometria para o efluente com o composto Flexzone 3P.
id UNSP_f242a5af42e0c0c0e579b26bdfcf8f7c
oai_identifier_str oai:repositorio.unesp.br:11449/20088
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodesElectrolytic treatmentwastewaterTi/TiRuO2 electrodesO presente trabalho apresenta os resultados dos tratamentos eletrolíticos (05; 15; 30; 45 e 60 min) no efluente simulado com o composto Flexzone 3P, utilizando-se eletrodos de Ti/TiRuO2, sob 0,025 A cm-2. Após as eletrólises, foram feitas análises de pH, condutividade, espectrofotometria no UV-vis, análise por cromatografia gasosa, ensaios de toxicidade utilizando Saccharomyces cerevisiae e ensaio de respirometria de Bartha. O pH dos efluentes foi diminuindo à medida que aumentou- se o tempo de eletrólise, ao contrário da condutividade, a qual apresentou pequeno aumento. Verificou-se que após 60 min de tratamento foi obtida diminuição da concentração do composto Flexzone 3P em 65,1%. Analisando-se os espectros de UV-vis e cromatogramas do efluente após realização do tratamento eletrolítico, concluiu-se que ocorreram oxidações e transformações de funções orgânicas do composto, durante os tratamentos. Após a realização do tratamento eletrolítico, o efluente simulado apresentou diminuição da toxicidade a S. cerevisiae, após 5 min de eletrólise. O tempo de eletrólise de 5 min foi o que apresentou melhor resultado de biodegradação do que os demais períodos de tratamento, no ensaio de respirometria para o efluente com o composto Flexzone 3P.This study investigated the effects of the electrolytic treatment in the simulated wastewater with aromatic amine n-phenyl-n-isopropyl-p-phenylenediamine (Flexzone 3P®) using Ti/TiRuO2 electrodes under 0.025 A/cm² (DC) for different electrolysis durations (5; 15; 30; 45 and 60 min). Conductivity, pH, UV-visible spectra, gas chromatograms, toxicity and biodegradation tests were carried out. During the electrolytic treatment the pH decreased and conductivity increased slightly. After 60 min of electrolysis, the concentration of Flexzone 3P decreased by 65.1%. UV-vis spectra and chromatograms of simulated wastewater showed changes in the molecular structure of the aromatic amine. After 5 and 15 min of electrolysis, the simulated wastewater containing the Flexzone 3P showed detoxification by Saccharomyces cerevisiae toxicity test. The electrolysis of 5 min improved the biodegradation of the simulated wastewater containing Flexzone 3P.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação para o Desenvolvimento da UNESP (FUNDUNESP)Universidade Estadual Paulista Instituto de Biociências Departamento de Bioquímica e MicrobiologiaUniversidade Estadual Paulista Instituto de Biociências Departamento de Bioquímica e MicrobiologiaBrazilian Archives of Biology and TechnologyUniversidade Estadual Paulista (Unesp)Inazaki, Thelma Helena [UNESP]Pião, Antonio Carlos Simões [UNESP]Bidoia, Ederio Dino [UNESP]2014-05-20T13:56:10Z2014-05-20T13:56:10Z2004-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article983-984application/pdfhttp://dx.doi.org/10.1590/S1516-89132004000600018Brazilian Archives of Biology and Technology. Brazilian Archives of Biology and Technology, v. 47, n. 6, p. 983-984, 2004.1516-8913http://hdl.handle.net/11449/2008810.1590/S1516-89132004000600018S1516-89132004000600018S1516-89132004000600018.pdf92203485835600430000-0001-7040-1983SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Archives of Biology and Technology0.6760,281info:eu-repo/semantics/openAccess2024-11-27T14:09:37Zoai:repositorio.unesp.br:11449/20088Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-11-27T14:09:37Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
title Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
spellingShingle Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
Inazaki, Thelma Helena [UNESP]
Electrolytic treatment
wastewater
Ti/TiRuO2 electrodes
title_short Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
title_full Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
title_fullStr Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
title_full_unstemmed Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
title_sort Treatment of simulated wastewater containing n-phenyl-n-isopropyl-p-phenylenediamine using electrolysis system with Ti/TiRuO2 electrodes
author Inazaki, Thelma Helena [UNESP]
author_facet Inazaki, Thelma Helena [UNESP]
Pião, Antonio Carlos Simões [UNESP]
Bidoia, Ederio Dino [UNESP]
author_role author
author2 Pião, Antonio Carlos Simões [UNESP]
Bidoia, Ederio Dino [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Inazaki, Thelma Helena [UNESP]
Pião, Antonio Carlos Simões [UNESP]
Bidoia, Ederio Dino [UNESP]
dc.subject.por.fl_str_mv Electrolytic treatment
wastewater
Ti/TiRuO2 electrodes
topic Electrolytic treatment
wastewater
Ti/TiRuO2 electrodes
description O presente trabalho apresenta os resultados dos tratamentos eletrolíticos (05; 15; 30; 45 e 60 min) no efluente simulado com o composto Flexzone 3P, utilizando-se eletrodos de Ti/TiRuO2, sob 0,025 A cm-2. Após as eletrólises, foram feitas análises de pH, condutividade, espectrofotometria no UV-vis, análise por cromatografia gasosa, ensaios de toxicidade utilizando Saccharomyces cerevisiae e ensaio de respirometria de Bartha. O pH dos efluentes foi diminuindo à medida que aumentou- se o tempo de eletrólise, ao contrário da condutividade, a qual apresentou pequeno aumento. Verificou-se que após 60 min de tratamento foi obtida diminuição da concentração do composto Flexzone 3P em 65,1%. Analisando-se os espectros de UV-vis e cromatogramas do efluente após realização do tratamento eletrolítico, concluiu-se que ocorreram oxidações e transformações de funções orgânicas do composto, durante os tratamentos. Após a realização do tratamento eletrolítico, o efluente simulado apresentou diminuição da toxicidade a S. cerevisiae, após 5 min de eletrólise. O tempo de eletrólise de 5 min foi o que apresentou melhor resultado de biodegradação do que os demais períodos de tratamento, no ensaio de respirometria para o efluente com o composto Flexzone 3P.
publishDate 2004
dc.date.none.fl_str_mv 2004-11-01
2014-05-20T13:56:10Z
2014-05-20T13:56:10Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1516-89132004000600018
Brazilian Archives of Biology and Technology. Brazilian Archives of Biology and Technology, v. 47, n. 6, p. 983-984, 2004.
1516-8913
http://hdl.handle.net/11449/20088
10.1590/S1516-89132004000600018
S1516-89132004000600018
S1516-89132004000600018.pdf
9220348583560043
0000-0001-7040-1983
url http://dx.doi.org/10.1590/S1516-89132004000600018
http://hdl.handle.net/11449/20088
identifier_str_mv Brazilian Archives of Biology and Technology. Brazilian Archives of Biology and Technology, v. 47, n. 6, p. 983-984, 2004.
1516-8913
10.1590/S1516-89132004000600018
S1516-89132004000600018
S1516-89132004000600018.pdf
9220348583560043
0000-0001-7040-1983
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Archives of Biology and Technology
0.676
0,281
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 983-984
application/pdf
dc.publisher.none.fl_str_mv Brazilian Archives of Biology and Technology
publisher.none.fl_str_mv Brazilian Archives of Biology and Technology
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834484398879145984