Stability of beta-titanium T-loop springs preactivated by gradual curvature
Main Author: | |
---|---|
Publication Date: | 2017 |
Other Authors: | , , , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da UNESP |
Download full: | http://dx.doi.org/10.1590/2177-6709.22.6.061-067.oar http://hdl.handle.net/11449/158225 |
Summary: | ABSTRACTObjective:Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation.Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm.Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time.Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced. |
id |
UNSP_f06961603034e6a935fdae3037e06d7c |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/158225 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Stability of beta-titanium T-loop springs preactivated by gradual curvatureOrthodonticsTooth movementOrthodontic wiresOrtodontiaMovimentação dentáriaFios ortodônticosABSTRACTObjective:Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation.Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm.Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time.Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced.RESUMOObjetivo:avaliar as mudanças no sistema de forças das molas T pré-ativadas por curvatura, devido ao alívio de tensão estrutural.Métodos:noventa molas em forma de “T”, medindo 6 mm x 10 mm, confeccionadas com fio de beta-titânio TMA® de 0,017” x 0,025” e pré-ativadas por curvatura gradual, foram distribuídas aleatoriamente em nove grupos, de acordo com o momento de avaliação. O Grupo 1 foi testado imediatamente após a pré-ativação da mola e liberação do estresse, por meio de simulação da ativação. Os outros oito grupos foram divididos conforme o intervalo de tempo testado: após 24, 48 e 72 horas; 1, 2, 4, 8 e 12 semanas. Usando um transdutor de momentos acoplado a um indicador digital para extensometria e adaptado a uma máquina universal de ensaios, as magnitudes da força horizontal, do momento e da proporção momento/força (M/F) foram registradas a cada 0,5 mm de desativação a partir da ativação inicial de 5 mm, utilizando-se uma distância interbraquetes de 23 mm.Resultados: as forças horizontais reduziram-se gradualmente nos grupos (p< 0,001) e o momento apresentou uma queda lenta e significativa ao longo do tempo (p< 0,001). Todos os grupos tiveram proporções M/F semelhantes (p= 0,532), não influenciadas pelo período de tempo.Conclusões:as molas pré-ativadas por curvatura gradual sofreram deformação progressiva ao longo do tempo, o que afetou o sistema de forças - especificamente o momento -, alterando as forças horizontais produzidas.Universidade Federal do Rio Grande do Norte Departamento de OdontologiaUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara Programa de Pós-graduação em Ciências Odontológicas - OrtodontiaAraraquaraUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara Departamento de Clínica InfantilUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara Programa de Pós-graduação em Ciências Odontológicas - OrtodontiaUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara Departamento de Clínica InfantilDental Press InternationalUniversidade Federal do Rio Grande do Norte Departamento de OdontologiaUniversidade Estadual Paulista (Unesp)AraraquaraCaldas, Sergei Godeiro Fernandes RabeloMartins, Renato ParsekianAraújo, Marcela Emílio DeGalvão, Marília RegaladoSilva Júnior, Roberto Soares DaMartins, Lídia Parsekian2018-11-12T17:28:54Z2018-11-12T17:28:54Z2017-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article61-67application/pdfhttp://dx.doi.org/10.1590/2177-6709.22.6.061-067.oarDental Press Journal of Orthodontics. Dental Press International, v. 22, n. 6, p. 61-67, 2017.2176-9451http://hdl.handle.net/11449/15822510.1590/2177-6709.22.6.061-067.oarS2176-94512017000600061S2176-94512017000600061.pdf8223795731605246SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengDental Press Journal of Orthodontics0,489info:eu-repo/semantics/openAccess2024-09-26T14:21:45Zoai:repositorio.unesp.br:11449/158225Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T14:21:45Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
title |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
spellingShingle |
Stability of beta-titanium T-loop springs preactivated by gradual curvature Caldas, Sergei Godeiro Fernandes Rabelo Orthodontics Tooth movement Orthodontic wires Ortodontia Movimentação dentária Fios ortodônticos |
title_short |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
title_full |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
title_fullStr |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
title_full_unstemmed |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
title_sort |
Stability of beta-titanium T-loop springs preactivated by gradual curvature |
author |
Caldas, Sergei Godeiro Fernandes Rabelo |
author_facet |
Caldas, Sergei Godeiro Fernandes Rabelo Martins, Renato Parsekian Araújo, Marcela Emílio De Galvão, Marília Regalado Silva Júnior, Roberto Soares Da Martins, Lídia Parsekian |
author_role |
author |
author2 |
Martins, Renato Parsekian Araújo, Marcela Emílio De Galvão, Marília Regalado Silva Júnior, Roberto Soares Da Martins, Lídia Parsekian |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte Departamento de Odontologia Universidade Estadual Paulista (Unesp) Araraquara |
dc.contributor.author.fl_str_mv |
Caldas, Sergei Godeiro Fernandes Rabelo Martins, Renato Parsekian Araújo, Marcela Emílio De Galvão, Marília Regalado Silva Júnior, Roberto Soares Da Martins, Lídia Parsekian |
dc.subject.por.fl_str_mv |
Orthodontics Tooth movement Orthodontic wires Ortodontia Movimentação dentária Fios ortodônticos |
topic |
Orthodontics Tooth movement Orthodontic wires Ortodontia Movimentação dentária Fios ortodônticos |
description |
ABSTRACTObjective:Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation.Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm.Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time.Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-11-01 2018-11-12T17:28:54Z 2018-11-12T17:28:54Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/2177-6709.22.6.061-067.oar Dental Press Journal of Orthodontics. Dental Press International, v. 22, n. 6, p. 61-67, 2017. 2176-9451 http://hdl.handle.net/11449/158225 10.1590/2177-6709.22.6.061-067.oar S2176-94512017000600061 S2176-94512017000600061.pdf 8223795731605246 |
url |
http://dx.doi.org/10.1590/2177-6709.22.6.061-067.oar http://hdl.handle.net/11449/158225 |
identifier_str_mv |
Dental Press Journal of Orthodontics. Dental Press International, v. 22, n. 6, p. 61-67, 2017. 2176-9451 10.1590/2177-6709.22.6.061-067.oar S2176-94512017000600061 S2176-94512017000600061.pdf 8223795731605246 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Dental Press Journal of Orthodontics 0,489 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
61-67 application/pdf |
dc.publisher.none.fl_str_mv |
Dental Press International |
publisher.none.fl_str_mv |
Dental Press International |
dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834484409078644736 |