Resumo: | Objectives: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). Content: Methods to evaluate the stability of dental implants. Summary: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined “resonance frequency analysis” and “Periotest” with “correlation” or “relationship”; and combinations of “implant stability quotient” and “Periotest” with “correlation” or “relationship.” The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability. Outlook: This review can serve as a reference for the development of methodologies for future clinical studies on this topic. |
id |
UNSP_dd919c6390133267f55ee97103b4f20d |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/297094 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Correlation between Periotest value and implant stability quotient: a systematic reviewcorrelation of datadental implantsosseointegrationperiotestresonance frequency analysisObjectives: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). Content: Methods to evaluate the stability of dental implants. Summary: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined “resonance frequency analysis” and “Periotest” with “correlation” or “relationship”; and combinations of “implant stability quotient” and “Periotest” with “correlation” or “relationship.” The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability. Outlook: This review can serve as a reference for the development of methodologies for future clinical studies on this topic.Department of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP), José Bonifácio street, 1193, Vila Mendonça, AraçatubaDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP) School of Dentistry, AraçatubaDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP), José Bonifácio street, 1193, Vila Mendonça, AraçatubaDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP) School of Dentistry, AraçatubaUniversidade Estadual Paulista (UNESP)Rodrigues, Alana Semenzin [UNESP]de Moraes Melo Neto, Clóvis Lamartine [UNESP]Januzzi, Marcella Santos [UNESP]dos Santos, Daniela Micheline [UNESP]Coelho Goiato, Marcelo [UNESP]2025-04-29T18:05:33Z2024-02-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/other1-10http://dx.doi.org/10.1515/bmt-2023-0194Biomedizinische Technik, v. 69, n. 1, p. 1-10, 2024.1862-278X0013-5585https://hdl.handle.net/11449/29709410.1515/bmt-2023-01942-s2.0-85167443737Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBiomedizinische Technikinfo:eu-repo/semantics/openAccess2025-05-01T05:06:35Zoai:repositorio.unesp.br:11449/297094Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-05-01T05:06:35Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Correlation between Periotest value and implant stability quotient: a systematic review |
title |
Correlation between Periotest value and implant stability quotient: a systematic review |
spellingShingle |
Correlation between Periotest value and implant stability quotient: a systematic review Rodrigues, Alana Semenzin [UNESP] correlation of data dental implants osseointegration periotest resonance frequency analysis |
title_short |
Correlation between Periotest value and implant stability quotient: a systematic review |
title_full |
Correlation between Periotest value and implant stability quotient: a systematic review |
title_fullStr |
Correlation between Periotest value and implant stability quotient: a systematic review |
title_full_unstemmed |
Correlation between Periotest value and implant stability quotient: a systematic review |
title_sort |
Correlation between Periotest value and implant stability quotient: a systematic review |
author |
Rodrigues, Alana Semenzin [UNESP] |
author_facet |
Rodrigues, Alana Semenzin [UNESP] de Moraes Melo Neto, Clóvis Lamartine [UNESP] Januzzi, Marcella Santos [UNESP] dos Santos, Daniela Micheline [UNESP] Coelho Goiato, Marcelo [UNESP] |
author_role |
author |
author2 |
de Moraes Melo Neto, Clóvis Lamartine [UNESP] Januzzi, Marcella Santos [UNESP] dos Santos, Daniela Micheline [UNESP] Coelho Goiato, Marcelo [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Rodrigues, Alana Semenzin [UNESP] de Moraes Melo Neto, Clóvis Lamartine [UNESP] Januzzi, Marcella Santos [UNESP] dos Santos, Daniela Micheline [UNESP] Coelho Goiato, Marcelo [UNESP] |
dc.subject.por.fl_str_mv |
correlation of data dental implants osseointegration periotest resonance frequency analysis |
topic |
correlation of data dental implants osseointegration periotest resonance frequency analysis |
description |
Objectives: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). Content: Methods to evaluate the stability of dental implants. Summary: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined “resonance frequency analysis” and “Periotest” with “correlation” or “relationship”; and combinations of “implant stability quotient” and “Periotest” with “correlation” or “relationship.” The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability. Outlook: This review can serve as a reference for the development of methodologies for future clinical studies on this topic. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-02-01 2025-04-29T18:05:33Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/other |
format |
other |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1515/bmt-2023-0194 Biomedizinische Technik, v. 69, n. 1, p. 1-10, 2024. 1862-278X 0013-5585 https://hdl.handle.net/11449/297094 10.1515/bmt-2023-0194 2-s2.0-85167443737 |
url |
http://dx.doi.org/10.1515/bmt-2023-0194 https://hdl.handle.net/11449/297094 |
identifier_str_mv |
Biomedizinische Technik, v. 69, n. 1, p. 1-10, 2024. 1862-278X 0013-5585 10.1515/bmt-2023-0194 2-s2.0-85167443737 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Biomedizinische Technik |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1-10 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834482537344270336 |