Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes

Bibliographic Details
Main Author: De Mattos, Ivanildo Luiz
Publication Date: 2002
Other Authors: Gorton, Lo, Ruzgas, Tautgirdas
Format: Article
Language: eng
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.1016/S0956-5663(02)00185-9
http://hdl.handle.net/11449/230923
Summary: Gold (Au) and platinum (Pt) screen-printed electrodes were modified with Prussian Blue (PB) for the development of amperometric sensors selective for hydrogen peroxide detection. The sensors exhibited sensitivities towards H2O2 equal to 2 A M-1 cm-2 for Au and 1 A M-1 cm-2 for Pt electrodes. The sensors were also employed as the basis for construction of glucose biosensors through further modification with crystallised glucose oxidase immobilised in a Nafion membrane. In order to improve the operational stability of the modified electrodes a buffer solution containing tetrabutylammonium toluene-4-sulfonate was used. The long-term performance of the sensors and biosensors were evaluated by continuous monitoring of hydrogen peroxide and glucose solutions (50 μM and 1 mM, respectively) in the flow-injection mode for 10 h. © 2002 Elsevier Science B.V. All rights reserved.
id UNSP_d565ab302a7f64ee9dc48dec2b643fc7
oai_identifier_str oai:repositorio.unesp.br:11449/230923
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodesAmperometric sensorBiosensorPrussian BlueScreen-printed electrodesGold (Au) and platinum (Pt) screen-printed electrodes were modified with Prussian Blue (PB) for the development of amperometric sensors selective for hydrogen peroxide detection. The sensors exhibited sensitivities towards H2O2 equal to 2 A M-1 cm-2 for Au and 1 A M-1 cm-2 for Pt electrodes. The sensors were also employed as the basis for construction of glucose biosensors through further modification with crystallised glucose oxidase immobilised in a Nafion membrane. In order to improve the operational stability of the modified electrodes a buffer solution containing tetrabutylammonium toluene-4-sulfonate was used. The long-term performance of the sensors and biosensors were evaluated by continuous monitoring of hydrogen peroxide and glucose solutions (50 μM and 1 mM, respectively) in the flow-injection mode for 10 h. © 2002 Elsevier Science B.V. All rights reserved.Department of Analytical Chemistry University of Lund, P.O. Box 124, S-22100 LundDepartamento de Química Faculdade de Ciências, P.O. Box 473, 17033-360 Bauru-SPUniversity of LundFaculdade de CiênciasDe Mattos, Ivanildo LuizGorton, LoRuzgas, Tautgirdas2022-04-29T08:42:46Z2022-04-29T08:42:46Z2002-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article193-200http://dx.doi.org/10.1016/S0956-5663(02)00185-9Biosensors and Bioelectronics, v. 18, n. 2-3, p. 193-200, 2002.0956-5663http://hdl.handle.net/11449/23092310.1016/S0956-5663(02)00185-92-s2.0-0036523407Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBiosensors and Bioelectronicsinfo:eu-repo/semantics/openAccess2024-04-29T18:16:48Zoai:repositorio.unesp.br:11449/230923Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-04-29T18:16:48Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
title Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
spellingShingle Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
De Mattos, Ivanildo Luiz
Amperometric sensor
Biosensor
Prussian Blue
Screen-printed electrodes
title_short Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
title_full Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
title_fullStr Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
title_full_unstemmed Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
title_sort Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
author De Mattos, Ivanildo Luiz
author_facet De Mattos, Ivanildo Luiz
Gorton, Lo
Ruzgas, Tautgirdas
author_role author
author2 Gorton, Lo
Ruzgas, Tautgirdas
author2_role author
author
dc.contributor.none.fl_str_mv University of Lund
Faculdade de Ciências
dc.contributor.author.fl_str_mv De Mattos, Ivanildo Luiz
Gorton, Lo
Ruzgas, Tautgirdas
dc.subject.por.fl_str_mv Amperometric sensor
Biosensor
Prussian Blue
Screen-printed electrodes
topic Amperometric sensor
Biosensor
Prussian Blue
Screen-printed electrodes
description Gold (Au) and platinum (Pt) screen-printed electrodes were modified with Prussian Blue (PB) for the development of amperometric sensors selective for hydrogen peroxide detection. The sensors exhibited sensitivities towards H2O2 equal to 2 A M-1 cm-2 for Au and 1 A M-1 cm-2 for Pt electrodes. The sensors were also employed as the basis for construction of glucose biosensors through further modification with crystallised glucose oxidase immobilised in a Nafion membrane. In order to improve the operational stability of the modified electrodes a buffer solution containing tetrabutylammonium toluene-4-sulfonate was used. The long-term performance of the sensors and biosensors were evaluated by continuous monitoring of hydrogen peroxide and glucose solutions (50 μM and 1 mM, respectively) in the flow-injection mode for 10 h. © 2002 Elsevier Science B.V. All rights reserved.
publishDate 2002
dc.date.none.fl_str_mv 2002-03-01
2022-04-29T08:42:46Z
2022-04-29T08:42:46Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/S0956-5663(02)00185-9
Biosensors and Bioelectronics, v. 18, n. 2-3, p. 193-200, 2002.
0956-5663
http://hdl.handle.net/11449/230923
10.1016/S0956-5663(02)00185-9
2-s2.0-0036523407
url http://dx.doi.org/10.1016/S0956-5663(02)00185-9
http://hdl.handle.net/11449/230923
identifier_str_mv Biosensors and Bioelectronics, v. 18, n. 2-3, p. 193-200, 2002.
0956-5663
10.1016/S0956-5663(02)00185-9
2-s2.0-0036523407
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Biosensors and Bioelectronics
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 193-200
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834483164196634624