Export Ready — 

Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency

Bibliographic Details
Main Author: Dal Piva, Amanda Maria de Oliveira [UNESP]
Publication Date: 2021
Other Authors: Tribst, João Paulo Mendes [UNESP], Benalcázar Jalkh, Ernesto Byron, Anami, Lilian Costa [UNESP], Bonfante, Estevam Augusto, Bottino, Marco Antonio [UNESP]
Format: Article
Language: eng
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.1016/j.dental.2020.11.001
http://hdl.handle.net/11449/208213
Summary: Objective: Despite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns. Methods: Dentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia – YZHT, Zirconia reinforced lithium silicate – ZLS and Hybrid ceramic – HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness. Results: Higher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2). Significance: HC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation.
id UNSP_c1ca8d4b35885810039135327cfcd51a
oai_identifier_str oai:repositorio.unesp.br:11449/208213
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucencyDental materialsFatigueMonolithic crownsReliabilityTooth wearObjective: Despite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns. Methods: Dentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia – YZHT, Zirconia reinforced lithium silicate – ZLS and Hybrid ceramic – HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness. Results: Higher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2). Significance: HC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)PhD Graduate Program in Restorative Dentistry São Paulo State University (Unesp) Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São DimasDepartment of Prosthodontics and Periodontology University of São Paulo – Bauru School of Dentistry, Alameda Dr. Octávio Pinheiro Brisolla, 9-75PhD Graduate Program in Restorative Dentistry São Paulo State University (Unesp) Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São DimasFAPESP: #2012/19078-7FAPESP: #2017/09104-4FAPESP: #2017/11535-3FAPESP: #2017/23059-1FAPESP: #2018/03072-6FAPESP: #2018/03984-5Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Dal Piva, Amanda Maria de Oliveira [UNESP]Tribst, João Paulo Mendes [UNESP]Benalcázar Jalkh, Ernesto ByronAnami, Lilian Costa [UNESP]Bonfante, Estevam AugustoBottino, Marco Antonio [UNESP]2021-06-25T11:08:17Z2021-06-25T11:08:17Z2021-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlee140-e150http://dx.doi.org/10.1016/j.dental.2020.11.001Dental Materials, v. 37, n. 3, p. e140-e150, 2021.0109-5641http://hdl.handle.net/11449/20821310.1016/j.dental.2020.11.0012-s2.0-85097093302Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengDental Materialsinfo:eu-repo/semantics/openAccess2024-11-18T13:35:23Zoai:repositorio.unesp.br:11449/208213Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-11-18T13:35:23Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
title Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
spellingShingle Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
Dal Piva, Amanda Maria de Oliveira [UNESP]
Dental materials
Fatigue
Monolithic crowns
Reliability
Tooth wear
title_short Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
title_full Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
title_fullStr Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
title_full_unstemmed Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
title_sort Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency
author Dal Piva, Amanda Maria de Oliveira [UNESP]
author_facet Dal Piva, Amanda Maria de Oliveira [UNESP]
Tribst, João Paulo Mendes [UNESP]
Benalcázar Jalkh, Ernesto Byron
Anami, Lilian Costa [UNESP]
Bonfante, Estevam Augusto
Bottino, Marco Antonio [UNESP]
author_role author
author2 Tribst, João Paulo Mendes [UNESP]
Benalcázar Jalkh, Ernesto Byron
Anami, Lilian Costa [UNESP]
Bonfante, Estevam Augusto
Bottino, Marco Antonio [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Dal Piva, Amanda Maria de Oliveira [UNESP]
Tribst, João Paulo Mendes [UNESP]
Benalcázar Jalkh, Ernesto Byron
Anami, Lilian Costa [UNESP]
Bonfante, Estevam Augusto
Bottino, Marco Antonio [UNESP]
dc.subject.por.fl_str_mv Dental materials
Fatigue
Monolithic crowns
Reliability
Tooth wear
topic Dental materials
Fatigue
Monolithic crowns
Reliability
Tooth wear
description Objective: Despite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns. Methods: Dentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia – YZHT, Zirconia reinforced lithium silicate – ZLS and Hybrid ceramic – HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness. Results: Higher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2). Significance: HC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-25T11:08:17Z
2021-06-25T11:08:17Z
2021-03-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.dental.2020.11.001
Dental Materials, v. 37, n. 3, p. e140-e150, 2021.
0109-5641
http://hdl.handle.net/11449/208213
10.1016/j.dental.2020.11.001
2-s2.0-85097093302
url http://dx.doi.org/10.1016/j.dental.2020.11.001
http://hdl.handle.net/11449/208213
identifier_str_mv Dental Materials, v. 37, n. 3, p. e140-e150, 2021.
0109-5641
10.1016/j.dental.2020.11.001
2-s2.0-85097093302
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Dental Materials
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv e140-e150
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834484588821348352