Export Ready — 

O uso do pool de plasma caseiro interfere no valor da rni?

Bibliographic Details
Main Author: Da Silva, Paulo Henrique
Publication Date: 2012
Other Authors: Correa, Janaína Risczik Arruda, Henneberg, Railson [UNESP], Do Nascimento, Aguinaldo José
Format: Article
Language: por
Source: Repositório Institucional da UNESP
Download full: http://dx.doi.org/10.1590/S1676-24442012000400006
http://hdl.handle.net/11449/73465
Summary: Introduction: The prothrombin time (PT) test is commonly used to monitor anticoagulant levels in patients undergoing oral anticoagulant therapy. Currently, anticoagulation levels have been assessed through the international normalized ratio (INR) value. Objective: The objective of this study was to determine if inhouse preparations of polled plasma, containing five (P5) and 20 (P20) samples, respectively, may be used as normal control of PT and to assess its interference in INR values. Material and methods: The experiment was performed in 32 days. Both polled plasma preparations were analyzed in comparison with a commercial control (PC). PT was performed for PC, P5 and P20 daily and the INR value for PC, P5 and P20 was assessed in patients undergoing oral anticoagulant therapy. The applied statistical tools were mean value (X), analysis of variance and Tukey test. Results: There were no statiscally significant differences in PT and INR for PC, P5 and P20. Conclusion: In-house polled plasma (P5 and P20) may be applied as normal control of PT and it does not interfere in the INR value.
id UNSP_787d0a02d6b421aee1b7ea097583874c
oai_identifier_str oai:repositorio.unesp.br:11449/73465
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling O uso do pool de plasma caseiro interfere no valor da rni?Does the use of in-house pooled plasma interfere in the inr value?International normalized ratioOral anticoagulantsProthrombin timeIntroduction: The prothrombin time (PT) test is commonly used to monitor anticoagulant levels in patients undergoing oral anticoagulant therapy. Currently, anticoagulation levels have been assessed through the international normalized ratio (INR) value. Objective: The objective of this study was to determine if inhouse preparations of polled plasma, containing five (P5) and 20 (P20) samples, respectively, may be used as normal control of PT and to assess its interference in INR values. Material and methods: The experiment was performed in 32 days. Both polled plasma preparations were analyzed in comparison with a commercial control (PC). PT was performed for PC, P5 and P20 daily and the INR value for PC, P5 and P20 was assessed in patients undergoing oral anticoagulant therapy. The applied statistical tools were mean value (X), analysis of variance and Tukey test. Results: There were no statiscally significant differences in PT and INR for PC, P5 and P20. Conclusion: In-house polled plasma (P5 and P20) may be applied as normal control of PT and it does not interfere in the INR value.Biologia Celular e Molecular Universidade Federal do Paraná UFPR, Av. Lothário Meissner, 632, Jardim Botânico CEP: 80210-170 - Curitiba-PRDepartamento de Patologia Médica UFPRHematologia Sociedade Brasileira de Análises Clínicas (SBAC)Farmacêutica Bioquímica Hospital Universitário Evangélico de Curitiba (HUEC)Análises Clínicas Universidade Estadual Paulista (UNESP) Campus AraraquaraUFPRBioquímicaPrograma de Pós-Graduação Ciências Farmacêuticas UFPRAnálises Clínicas Universidade Estadual Paulista (UNESP) Campus AraraquaraUniversidade Federal do Paraná (UFPR)Sociedade Brasileira de Análises Clínicas (SBAC)Hospital Universitário Evangélico de Curitiba (HUEC)Universidade Estadual Paulista (Unesp)BioquímicaDa Silva, Paulo HenriqueCorrea, Janaína Risczik ArrudaHenneberg, Railson [UNESP]Do Nascimento, Aguinaldo José2014-05-27T11:26:53Z2014-05-27T11:26:53Z2012-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article265-268application/pdfhttp://dx.doi.org/10.1590/S1676-24442012000400006Jornal Brasileiro de Patologia e Medicina Laboratorial, v. 48, n. 4, p. 265-268, 2012.1676-24441678-4774http://hdl.handle.net/11449/7346510.1590/S1676-24442012000400006S1676-244420120004000062-s2.0-848671381872-s2.0-84867138187.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporJornal Brasileiro de Patologia e Medicina Laboratorial0,143info:eu-repo/semantics/openAccess2025-03-29T05:11:03Zoai:repositorio.unesp.br:11449/73465Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-03-29T05:11:03Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv O uso do pool de plasma caseiro interfere no valor da rni?
Does the use of in-house pooled plasma interfere in the inr value?
title O uso do pool de plasma caseiro interfere no valor da rni?
spellingShingle O uso do pool de plasma caseiro interfere no valor da rni?
Da Silva, Paulo Henrique
International normalized ratio
Oral anticoagulants
Prothrombin time
title_short O uso do pool de plasma caseiro interfere no valor da rni?
title_full O uso do pool de plasma caseiro interfere no valor da rni?
title_fullStr O uso do pool de plasma caseiro interfere no valor da rni?
title_full_unstemmed O uso do pool de plasma caseiro interfere no valor da rni?
title_sort O uso do pool de plasma caseiro interfere no valor da rni?
author Da Silva, Paulo Henrique
author_facet Da Silva, Paulo Henrique
Correa, Janaína Risczik Arruda
Henneberg, Railson [UNESP]
Do Nascimento, Aguinaldo José
author_role author
author2 Correa, Janaína Risczik Arruda
Henneberg, Railson [UNESP]
Do Nascimento, Aguinaldo José
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Federal do Paraná (UFPR)
Sociedade Brasileira de Análises Clínicas (SBAC)
Hospital Universitário Evangélico de Curitiba (HUEC)
Universidade Estadual Paulista (Unesp)
Bioquímica
dc.contributor.author.fl_str_mv Da Silva, Paulo Henrique
Correa, Janaína Risczik Arruda
Henneberg, Railson [UNESP]
Do Nascimento, Aguinaldo José
dc.subject.por.fl_str_mv International normalized ratio
Oral anticoagulants
Prothrombin time
topic International normalized ratio
Oral anticoagulants
Prothrombin time
description Introduction: The prothrombin time (PT) test is commonly used to monitor anticoagulant levels in patients undergoing oral anticoagulant therapy. Currently, anticoagulation levels have been assessed through the international normalized ratio (INR) value. Objective: The objective of this study was to determine if inhouse preparations of polled plasma, containing five (P5) and 20 (P20) samples, respectively, may be used as normal control of PT and to assess its interference in INR values. Material and methods: The experiment was performed in 32 days. Both polled plasma preparations were analyzed in comparison with a commercial control (PC). PT was performed for PC, P5 and P20 daily and the INR value for PC, P5 and P20 was assessed in patients undergoing oral anticoagulant therapy. The applied statistical tools were mean value (X), analysis of variance and Tukey test. Results: There were no statiscally significant differences in PT and INR for PC, P5 and P20. Conclusion: In-house polled plasma (P5 and P20) may be applied as normal control of PT and it does not interfere in the INR value.
publishDate 2012
dc.date.none.fl_str_mv 2012-08-01
2014-05-27T11:26:53Z
2014-05-27T11:26:53Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1676-24442012000400006
Jornal Brasileiro de Patologia e Medicina Laboratorial, v. 48, n. 4, p. 265-268, 2012.
1676-2444
1678-4774
http://hdl.handle.net/11449/73465
10.1590/S1676-24442012000400006
S1676-24442012000400006
2-s2.0-84867138187
2-s2.0-84867138187.pdf
url http://dx.doi.org/10.1590/S1676-24442012000400006
http://hdl.handle.net/11449/73465
identifier_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial, v. 48, n. 4, p. 265-268, 2012.
1676-2444
1678-4774
10.1590/S1676-24442012000400006
S1676-24442012000400006
2-s2.0-84867138187
2-s2.0-84867138187.pdf
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial
0,143
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 265-268
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1834482590574182400