Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits
Main Author: | |
---|---|
Publication Date: | 2023 |
Other Authors: | , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da UNESP |
Download full: | http://dx.doi.org/10.1590/0103-6440202305352 https://hdl.handle.net/11449/301321 |
Summary: | The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of nondecalcified histological sections and evaluation of the bone implant contact (°/o BIC) as well as the fraction of bone tissue area between the implant threads (%BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.850/0 vs. 29.49 ± 10.27Q/6) and %BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface. |
id |
UNSP_61c36acbb595516f114f22ee2d824eb2 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/301321 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbitsBone-implant interfaceDental implantsOsseointegrationThe aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of nondecalcified histological sections and evaluation of the bone implant contact (°/o BIC) as well as the fraction of bone tissue area between the implant threads (%BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.850/0 vs. 29.49 ± 10.27Q/6) and %BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.São Paulo State University (Unesp) School of Dentistry Araraquara Department of Diagnosis and SurgeryDepartment of Periodontology Federal University of UberlândiaInstituto Latino-americano de pesquisa odontológica (ILAPEO)University of Araraquara (Uniara) School of Dentistry Post-graduation im ImplantologySão Paulo State University (Unesp) School of Dentistry Araraquara Department of Diagnosis and SurgeryUniversidade Estadual Paulista (UNESP)Universidade Federal de Uberlândia (UFU)Instituto Latino-americano de pesquisa odontológica (ILAPEO)Post-graduation im ImplantologyPinto, Gustavo Da Col Santos [UNESP]Dos Reis, Isadora Aparecida RibeiroLeocádio, Amanda De Carvalho Silva [UNESP]Silva, MatusalemFaeda, Rafael SilveiraDe Oliveira, Guilherme José Pimentel LopesMarcantonio, Elcio [UNESP]2025-04-29T18:57:50Z2023-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article66-72http://dx.doi.org/10.1590/0103-6440202305352Brazilian Dental Journal, v. 34, n. 3, p. 66-72, 2023.1806-47600103-6440https://hdl.handle.net/11449/30132110.1590/0103-64402023053522-s2.0-85165517564Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journalinfo:eu-repo/semantics/openAccess2025-05-01T05:53:23Zoai:repositorio.unesp.br:11449/301321Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-05-01T05:53:23Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
title |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
spellingShingle |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits Pinto, Gustavo Da Col Santos [UNESP] Bone-implant interface Dental implants Osseointegration |
title_short |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
title_full |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
title_fullStr |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
title_full_unstemmed |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
title_sort |
Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits |
author |
Pinto, Gustavo Da Col Santos [UNESP] |
author_facet |
Pinto, Gustavo Da Col Santos [UNESP] Dos Reis, Isadora Aparecida Ribeiro Leocádio, Amanda De Carvalho Silva [UNESP] Silva, Matusalem Faeda, Rafael Silveira De Oliveira, Guilherme José Pimentel Lopes Marcantonio, Elcio [UNESP] |
author_role |
author |
author2 |
Dos Reis, Isadora Aparecida Ribeiro Leocádio, Amanda De Carvalho Silva [UNESP] Silva, Matusalem Faeda, Rafael Silveira De Oliveira, Guilherme José Pimentel Lopes Marcantonio, Elcio [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) Universidade Federal de Uberlândia (UFU) Instituto Latino-americano de pesquisa odontológica (ILAPEO) Post-graduation im Implantology |
dc.contributor.author.fl_str_mv |
Pinto, Gustavo Da Col Santos [UNESP] Dos Reis, Isadora Aparecida Ribeiro Leocádio, Amanda De Carvalho Silva [UNESP] Silva, Matusalem Faeda, Rafael Silveira De Oliveira, Guilherme José Pimentel Lopes Marcantonio, Elcio [UNESP] |
dc.subject.por.fl_str_mv |
Bone-implant interface Dental implants Osseointegration |
topic |
Bone-implant interface Dental implants Osseointegration |
description |
The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of nondecalcified histological sections and evaluation of the bone implant contact (°/o BIC) as well as the fraction of bone tissue area between the implant threads (%BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.850/0 vs. 29.49 ± 10.27Q/6) and %BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-01-01 2025-04-29T18:57:50Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/0103-6440202305352 Brazilian Dental Journal, v. 34, n. 3, p. 66-72, 2023. 1806-4760 0103-6440 https://hdl.handle.net/11449/301321 10.1590/0103-6440202305352 2-s2.0-85165517564 |
url |
http://dx.doi.org/10.1590/0103-6440202305352 https://hdl.handle.net/11449/301321 |
identifier_str_mv |
Brazilian Dental Journal, v. 34, n. 3, p. 66-72, 2023. 1806-4760 0103-6440 10.1590/0103-6440202305352 2-s2.0-85165517564 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian Dental Journal |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
66-72 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834482518204612608 |