Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats
Main Author: | |
---|---|
Publication Date: | 2025 |
Other Authors: | , , , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da UNESP |
Download full: | http://dx.doi.org/10.17221/73/2024-VETMED https://hdl.handle.net/11449/306901 |
Summary: | Ten sets of vertebral biomodels and the corresponding drilling guides were created to evaluate the implantation accuracy in the cervical (C5–C6) and lumbar (L4–L5) vertebrae of cats. Smooth pins were implanted using the guides on the right side of five randomly assigned biomodel sets and on the left side of the remaining sets, with the contralateral side undergoing freehand implantation. Subsequently, a new tomographic study was conducted to measure the implantation angles. The pre-implantation angles were compared with the post-implantation angles between the techniques and among the sets. The guide-assisted implantation exhibited a lower dispersion compared to the freehand technique, with coefficients of variation of –1.95 and 48.9 in the cervical vertebrae and 1.98 and 9.39 in the lumbar vertebrae, respectively. However, no statistical difference was observed between the pre- and post-implantation angles, nor when comparing the vertebral segments (P > 0.05). Under the study conditions, the use of the guide failed to result in more accurate implantations in the C5–C6 and L4–L5 vertebral biomodels of cats. |
id |
UNSP_5fe893f6fce68b8d76a9afd75e35f5ad |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/306901 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in catsiatrogenic diseaseneurosurgerythree-dimensional printingvertebral bodyTen sets of vertebral biomodels and the corresponding drilling guides were created to evaluate the implantation accuracy in the cervical (C5–C6) and lumbar (L4–L5) vertebrae of cats. Smooth pins were implanted using the guides on the right side of five randomly assigned biomodel sets and on the left side of the remaining sets, with the contralateral side undergoing freehand implantation. Subsequently, a new tomographic study was conducted to measure the implantation angles. The pre-implantation angles were compared with the post-implantation angles between the techniques and among the sets. The guide-assisted implantation exhibited a lower dispersion compared to the freehand technique, with coefficients of variation of –1.95 and 48.9 in the cervical vertebrae and 1.98 and 9.39 in the lumbar vertebrae, respectively. However, no statistical difference was observed between the pre- and post-implantation angles, nor when comparing the vertebral segments (P > 0.05). Under the study conditions, the use of the guide failed to result in more accurate implantations in the C5–C6 and L4–L5 vertebral biomodels of cats.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Department of Veterinary Medicine and Veterinary Surgery State University “Júlio de Mesquita Filho” UNESP, SPFederal University of Jataí UFJ, GODepartment of Veterinary Medicine and Veterinary Surgery State University “Júlio de Mesquita Filho” UNESP, SPCNPq: 140962/2020-4FAPESP: 2020/04404-2FAPESP: 2020/04695-7Universidade Estadual Paulista (UNESP)UFJCosta, Rodrigo Casarin [UNESP]de Moraes, Gabriel Godoi [UNESP]Ferreira, Rafaela Gerbasi [UNESP]Neto, Renato Barroco [UNESP]Nobile, Matheus [UNESP]de Sa Rocha, Thiago Andre Salvittide Barros, Luciano Pereira [UNESP]Minto, Bruno Watanabe [UNESP]Dias, Luis Gustavo Gosuen Goncalves [UNESP]2025-04-29T20:07:35Z2025-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article11-19http://dx.doi.org/10.17221/73/2024-VETMEDVeterinarni Medicina, v. 70, n. 1, p. 11-19, 2025.0375-8427https://hdl.handle.net/11449/30690110.17221/73/2024-VETMED2-s2.0-85217652517Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengVeterinarni Medicinainfo:eu-repo/semantics/openAccess2025-04-30T14:37:05Zoai:repositorio.unesp.br:11449/306901Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-04-30T14:37:05Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
title |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
spellingShingle |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats Costa, Rodrigo Casarin [UNESP] iatrogenic disease neurosurgery three-dimensional printing vertebral body |
title_short |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
title_full |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
title_fullStr |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
title_full_unstemmed |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
title_sort |
Assessment of the accuracy of patient-specific drilling guides for cervical (C5–C6) and lumbar (L4–L5) vertebrae in cats |
author |
Costa, Rodrigo Casarin [UNESP] |
author_facet |
Costa, Rodrigo Casarin [UNESP] de Moraes, Gabriel Godoi [UNESP] Ferreira, Rafaela Gerbasi [UNESP] Neto, Renato Barroco [UNESP] Nobile, Matheus [UNESP] de Sa Rocha, Thiago Andre Salvitti de Barros, Luciano Pereira [UNESP] Minto, Bruno Watanabe [UNESP] Dias, Luis Gustavo Gosuen Goncalves [UNESP] |
author_role |
author |
author2 |
de Moraes, Gabriel Godoi [UNESP] Ferreira, Rafaela Gerbasi [UNESP] Neto, Renato Barroco [UNESP] Nobile, Matheus [UNESP] de Sa Rocha, Thiago Andre Salvitti de Barros, Luciano Pereira [UNESP] Minto, Bruno Watanabe [UNESP] Dias, Luis Gustavo Gosuen Goncalves [UNESP] |
author2_role |
author author author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) UFJ |
dc.contributor.author.fl_str_mv |
Costa, Rodrigo Casarin [UNESP] de Moraes, Gabriel Godoi [UNESP] Ferreira, Rafaela Gerbasi [UNESP] Neto, Renato Barroco [UNESP] Nobile, Matheus [UNESP] de Sa Rocha, Thiago Andre Salvitti de Barros, Luciano Pereira [UNESP] Minto, Bruno Watanabe [UNESP] Dias, Luis Gustavo Gosuen Goncalves [UNESP] |
dc.subject.por.fl_str_mv |
iatrogenic disease neurosurgery three-dimensional printing vertebral body |
topic |
iatrogenic disease neurosurgery three-dimensional printing vertebral body |
description |
Ten sets of vertebral biomodels and the corresponding drilling guides were created to evaluate the implantation accuracy in the cervical (C5–C6) and lumbar (L4–L5) vertebrae of cats. Smooth pins were implanted using the guides on the right side of five randomly assigned biomodel sets and on the left side of the remaining sets, with the contralateral side undergoing freehand implantation. Subsequently, a new tomographic study was conducted to measure the implantation angles. The pre-implantation angles were compared with the post-implantation angles between the techniques and among the sets. The guide-assisted implantation exhibited a lower dispersion compared to the freehand technique, with coefficients of variation of –1.95 and 48.9 in the cervical vertebrae and 1.98 and 9.39 in the lumbar vertebrae, respectively. However, no statistical difference was observed between the pre- and post-implantation angles, nor when comparing the vertebral segments (P > 0.05). Under the study conditions, the use of the guide failed to result in more accurate implantations in the C5–C6 and L4–L5 vertebral biomodels of cats. |
publishDate |
2025 |
dc.date.none.fl_str_mv |
2025-04-29T20:07:35Z 2025-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.17221/73/2024-VETMED Veterinarni Medicina, v. 70, n. 1, p. 11-19, 2025. 0375-8427 https://hdl.handle.net/11449/306901 10.17221/73/2024-VETMED 2-s2.0-85217652517 |
url |
http://dx.doi.org/10.17221/73/2024-VETMED https://hdl.handle.net/11449/306901 |
identifier_str_mv |
Veterinarni Medicina, v. 70, n. 1, p. 11-19, 2025. 0375-8427 10.17221/73/2024-VETMED 2-s2.0-85217652517 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Veterinarni Medicina |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
11-19 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834482459788443648 |