Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection

Bibliographic Details
Main Author: Andrade, Maria Claudina Camargo de [UNIFESP]
Publication Date: 2005
Other Authors: Di Marco, Giovana Seno [UNIFESP], Felipe, Claudia Rosso [UNIFESP], Alfieri, Fernando, Tedesco-Silva Junior, Hélio [UNIFESP], Pestana, José Osmar Medina [UNIFESP], Casarini, Dulce Elena [UNIFESP]
Format: Article
Language: eng
Source: Repositório Institucional da UNIFESP
Download full: http://dx.doi.org/10.1111/j.1432-2277.2004.00066.x
http://repositorio.unifesp.br/handle/11600/28163
Summary: The need to adapt optimal conditions of sirolimus blood level monitoring in laboratories led us to optimize an high-performance liquid chromatography-ultraviolet method and compare the elution performances using the mobile phase A, 68% MeOH/2% acetonitrile (ACN)/30% H2O and mobile phase B, 30% MeOH/42% ACN/28% H2O. Samples were assayed with 1-chlorobutane, redissolved in MeOH/water and injected onto a C-18 column at 50 degrees C. the assay achieved sensitivity of 2.5-150 ng/ml (CV = 10.6%) and recovery of 92-103.6%. the intra- and interassay precisions ranged from 3.3% to 13% and from 5.9% to 15% for quality controls of 7.5, 60 and 120 ng/ml. the mobile phase A was unable to elute and recover sirolimus and internal standard in the expected retention time and concentration. Under our working conditions, the assay was precise, accurate and sensible, stressing the importance of establishing for the best working conditions according to the staff and demands of the laboratory.
id UFSP_e962d76d74b51ef9f33b4d185637f702
oai_identifier_str oai:repositorio.unifesp.br/:11600/28163
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Sirolimus quantification by high-performance liquid chromatography with ultraviolet detectionhigh-performance liquid chromatographysirolimusultraviolet detectionwhole bloodThe need to adapt optimal conditions of sirolimus blood level monitoring in laboratories led us to optimize an high-performance liquid chromatography-ultraviolet method and compare the elution performances using the mobile phase A, 68% MeOH/2% acetonitrile (ACN)/30% H2O and mobile phase B, 30% MeOH/42% ACN/28% H2O. Samples were assayed with 1-chlorobutane, redissolved in MeOH/water and injected onto a C-18 column at 50 degrees C. the assay achieved sensitivity of 2.5-150 ng/ml (CV = 10.6%) and recovery of 92-103.6%. the intra- and interassay precisions ranged from 3.3% to 13% and from 5.9% to 15% for quality controls of 7.5, 60 and 120 ng/ml. the mobile phase A was unable to elute and recover sirolimus and internal standard in the expected retention time and concentration. Under our working conditions, the assay was precise, accurate and sensible, stressing the importance of establishing for the best working conditions according to the staff and demands of the laboratory.Universidade Federal de São Paulo, Escola Paulista Med, Dept Med, Div Nephrol, BR-04023900 São Paulo, BrazilUniversidade Federal de São Paulo, Fdn Oswaldo Ramos, Dept Med, Div Nephrol, BR-04023900 São Paulo, BrazilWyeth Ayerst Res, São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Dept Med, Div Nephrol, BR-04023900 São Paulo, BrazilUniversidade Federal de São Paulo, Fdn Oswaldo Ramos, Dept Med, Div Nephrol, BR-04023900 São Paulo, BrazilWeb of ScienceBlackwell Publishing LtdUniversidade Federal de São Paulo (UNIFESP)Wyeth Ayerst ResAndrade, Maria Claudina Camargo de [UNIFESP]Di Marco, Giovana Seno [UNIFESP]Felipe, Claudia Rosso [UNIFESP]Alfieri, FernandoTedesco-Silva Junior, Hélio [UNIFESP]Pestana, José Osmar Medina [UNIFESP]Casarini, Dulce Elena [UNIFESP]2016-01-24T12:37:41Z2016-01-24T12:37:41Z2005-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion354-359http://dx.doi.org/10.1111/j.1432-2277.2004.00066.xTransplant International. Oxford: Blackwell Publishing Ltd, v. 18, n. 3, p. 354-359, 2005.10.1111/j.1432-2277.2004.00066.x0934-0874http://repositorio.unifesp.br/handle/11600/28163WOS:000227714800014engTransplant Internationalinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2016-01-24T10:37:41Zoai:repositorio.unifesp.br/:11600/28163Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652016-01-24T10:37:41Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
title Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
spellingShingle Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
Andrade, Maria Claudina Camargo de [UNIFESP]
high-performance liquid chromatography
sirolimus
ultraviolet detection
whole blood
title_short Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
title_full Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
title_fullStr Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
title_full_unstemmed Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
title_sort Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
author Andrade, Maria Claudina Camargo de [UNIFESP]
author_facet Andrade, Maria Claudina Camargo de [UNIFESP]
Di Marco, Giovana Seno [UNIFESP]
Felipe, Claudia Rosso [UNIFESP]
Alfieri, Fernando
Tedesco-Silva Junior, Hélio [UNIFESP]
Pestana, José Osmar Medina [UNIFESP]
Casarini, Dulce Elena [UNIFESP]
author_role author
author2 Di Marco, Giovana Seno [UNIFESP]
Felipe, Claudia Rosso [UNIFESP]
Alfieri, Fernando
Tedesco-Silva Junior, Hélio [UNIFESP]
Pestana, José Osmar Medina [UNIFESP]
Casarini, Dulce Elena [UNIFESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
Wyeth Ayerst Res
dc.contributor.author.fl_str_mv Andrade, Maria Claudina Camargo de [UNIFESP]
Di Marco, Giovana Seno [UNIFESP]
Felipe, Claudia Rosso [UNIFESP]
Alfieri, Fernando
Tedesco-Silva Junior, Hélio [UNIFESP]
Pestana, José Osmar Medina [UNIFESP]
Casarini, Dulce Elena [UNIFESP]
dc.subject.por.fl_str_mv high-performance liquid chromatography
sirolimus
ultraviolet detection
whole blood
topic high-performance liquid chromatography
sirolimus
ultraviolet detection
whole blood
description The need to adapt optimal conditions of sirolimus blood level monitoring in laboratories led us to optimize an high-performance liquid chromatography-ultraviolet method and compare the elution performances using the mobile phase A, 68% MeOH/2% acetonitrile (ACN)/30% H2O and mobile phase B, 30% MeOH/42% ACN/28% H2O. Samples were assayed with 1-chlorobutane, redissolved in MeOH/water and injected onto a C-18 column at 50 degrees C. the assay achieved sensitivity of 2.5-150 ng/ml (CV = 10.6%) and recovery of 92-103.6%. the intra- and interassay precisions ranged from 3.3% to 13% and from 5.9% to 15% for quality controls of 7.5, 60 and 120 ng/ml. the mobile phase A was unable to elute and recover sirolimus and internal standard in the expected retention time and concentration. Under our working conditions, the assay was precise, accurate and sensible, stressing the importance of establishing for the best working conditions according to the staff and demands of the laboratory.
publishDate 2005
dc.date.none.fl_str_mv 2005-03-01
2016-01-24T12:37:41Z
2016-01-24T12:37:41Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1111/j.1432-2277.2004.00066.x
Transplant International. Oxford: Blackwell Publishing Ltd, v. 18, n. 3, p. 354-359, 2005.
10.1111/j.1432-2277.2004.00066.x
0934-0874
http://repositorio.unifesp.br/handle/11600/28163
WOS:000227714800014
url http://dx.doi.org/10.1111/j.1432-2277.2004.00066.x
http://repositorio.unifesp.br/handle/11600/28163
identifier_str_mv Transplant International. Oxford: Blackwell Publishing Ltd, v. 18, n. 3, p. 354-359, 2005.
10.1111/j.1432-2277.2004.00066.x
0934-0874
WOS:000227714800014
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Transplant International
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 354-359
dc.publisher.none.fl_str_mv Blackwell Publishing Ltd
publisher.none.fl_str_mv Blackwell Publishing Ltd
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1841453731031285760