Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
| Main Author: | |
|---|---|
| Publication Date: | 2018 |
| Format: | Doctoral thesis |
| Language: | por |
| Source: | Manancial - Repositório Digital da UFSM |
| dARK ID: | ark:/26339/0013000015d5h |
| Download full: | http://repositorio.ufsm.br/handle/1/14295 |
Summary: | The present thesis is composed by two scientific articles that evaluated the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns and discs adhesively cemented to a dentin analogue material (epoxy resin). Therefore, eighty crowns with simplified geometry and eighty feldspathic ceramic discs (Vita Mark II, Vita Zahnfabrik) were randomly allocated, and the intaglio surface of each crown/disc was treated with one of the four surface conditioning methods (n=20): nonetched / control (CTRL), or etched for 60 s with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), or 10% (HF10). The treated ceramic surface received the application of a silane coupling agent. The cementation surface of simplified complete crown preparations and discs (both in epoxy resin) were etched with 10% hydrofluoric acid for 60 s and received a primer coating specific to the cementation system. After the surface treatments, the ceramic crowns and discs were adhesively cemented to the respective prosthetic preparations and epoxy resin discs, which were subjected to cyclic loads in water by a staircase approach (500,000 cycles, 20 Hz). Fatigue failure load data were analyzed by 1-way ANOVA and Tukey’s tests (α= .05). For the ceramic crowns, mean failure loads of groups CTRL (245.0 ± 15.1 N), HF1 (242.5 ± 24.7 N) and HF10 (255.7 ± 53.8 N) were statistically similar (P>.05), while the mean load of the HF5 group (216.7 ± 22.5 N) was significantly lower. In the condition of cemented discs, mean failure load of the HF5 group (255.0 ± 23.0 N) was also significantly lower; HF1 group (301.7 ± 71.0 N) presented intermediate values, and the highest values were achieved in CTRL (351.7 ± 13.4 N) and HF10 (341.7 ± 20.6 N) groups. Etching with 5% hydrofluoric acid had a deleterious effect on the fatigue failure loads of adhesively cemented feldspathic ceramic crowns and discs, while etching with 10% hydrofluoric acid had no negative influence in both tested conditions (crowns and discs). |
| id |
UFSM_3f327f5eaff24e2a72be409b9b5cb6f4 |
|---|---|
| oai_identifier_str |
oai:repositorio.ufsm.br:1/14295 |
| network_acronym_str |
UFSM |
| network_name_str |
Manancial - Repositório Digital da UFSM |
| repository_id_str |
|
| spelling |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentadaEffect of hydrofluoric acid concentration on the fatigue failure load of a cemented feldspathic ceramicÁcido fluorídricoCarregamento cíclicoCerâmica feldspáticaFadigaTratamento de superfícieCyclic loadingFatigueFeldspathic ceramicHydrofluoric acidSurface treatmentCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAThe present thesis is composed by two scientific articles that evaluated the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns and discs adhesively cemented to a dentin analogue material (epoxy resin). Therefore, eighty crowns with simplified geometry and eighty feldspathic ceramic discs (Vita Mark II, Vita Zahnfabrik) were randomly allocated, and the intaglio surface of each crown/disc was treated with one of the four surface conditioning methods (n=20): nonetched / control (CTRL), or etched for 60 s with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), or 10% (HF10). The treated ceramic surface received the application of a silane coupling agent. The cementation surface of simplified complete crown preparations and discs (both in epoxy resin) were etched with 10% hydrofluoric acid for 60 s and received a primer coating specific to the cementation system. After the surface treatments, the ceramic crowns and discs were adhesively cemented to the respective prosthetic preparations and epoxy resin discs, which were subjected to cyclic loads in water by a staircase approach (500,000 cycles, 20 Hz). Fatigue failure load data were analyzed by 1-way ANOVA and Tukey’s tests (α= .05). For the ceramic crowns, mean failure loads of groups CTRL (245.0 ± 15.1 N), HF1 (242.5 ± 24.7 N) and HF10 (255.7 ± 53.8 N) were statistically similar (P>.05), while the mean load of the HF5 group (216.7 ± 22.5 N) was significantly lower. In the condition of cemented discs, mean failure load of the HF5 group (255.0 ± 23.0 N) was also significantly lower; HF1 group (301.7 ± 71.0 N) presented intermediate values, and the highest values were achieved in CTRL (351.7 ± 13.4 N) and HF10 (341.7 ± 20.6 N) groups. Etching with 5% hydrofluoric acid had a deleterious effect on the fatigue failure loads of adhesively cemented feldspathic ceramic crowns and discs, while etching with 10% hydrofluoric acid had no negative influence in both tested conditions (crowns and discs).Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESA presente tese é composta por dois artigos científicos que avaliaram a influência de diferentes concentrações de ácido fluorídrico na carga para falha em fadiga de coroas e discos de cerâmica feldspática cimentados à um material análogo a dentina (resina epóxi). Para tanto, oitenta coroas com geometria simplificada e oitenta discos de cerâmica feldspática (Vita Mark II, Vita Zahnfabrik) foram divididos aleatoriamente, e a superfície interna de cada coroa/disco foi tratada de acordo com um dos quatro métodos de condicionamento de superfície (n=20): sem condicionamento/controle (CTRL), ou condicionamento por 60 s com diferentes concentrações de ácido fluorídrico: 1% (HF1), 5% (HF5) ou 10% (HF10). A superfície cerâmica tratada recebeu a aplicação de um agente de união silano. A superfície de cimentação dos preparos para coroas totais simplificadas e dos discos (ambos em resina epóxi) foram condicionados com ácido fluorídrico 10% por 60 s seguido da aplicação de uma camada de adesivo específico do sistema de cimentação. Após os tratamentos de superfície, as coroas e discos cerâmicos foram cimentados adesivamente aos respectivos preparos protéticos e discos de resina epóxi, os quais foram submetidos a cargas cíclicas em água pelo método da escada (500.000 ciclos, 20 Hz). Os dados de carga para falha em fadiga foram analisados pela análise de variância (ANOVA-1 fator) e testes de Tukey (α=0,05). Para as coroas cerâmicas, as cargas médias para falha em fadiga dos grupos CTRL (245,0 ± 15,1 N), HF1 (242,5 ± 24,7 N) e HF10 (255,7 ± 53,8 N) foram estatisticamente semelhantes (P>0,05), enquanto que a carga média do grupo HF5 (216,7 ± 22,5 N) foi significativamente inferior. Na condição de discos cimentados, a carga de falha média do grupo HF5 (255,0 ± 23,0 N) também foi significativamente inferior; o grupo HF1 (301,7 ± 71,0 N) apresentou valores intermediários e os valores mais altos foram alcançados nos grupos CTRL (351,7 ± 13,4 N) e HF10 (341,7 ± 20,6 N). O condicionamento com ácido fluorídrico 5% teve um efeito deletério nos valores de carga para falha em fadiga de coroas e discos de cerâmica feldspática cimentados adesivamente, visto que o condicionamento com ácido fluorídrico 10% não teve influência negativa em ambas as condições testadas (coroas e discos).Universidade Federal de Santa MariaBrasilOdontologiaUFSMPrograma de Pós-Graduação em Ciências OdontológicasCentro de Ciências da SaúdeValandro, Luiz Felipehttp://lattes.cnpq.br/0535309012233484Rippe, Marília Pivettahttp://lattes.cnpq.br/3336921465345785Bergoli, César Dalmolinhttp://lattes.cnpq.br/4313918234580023Aurélio, Iana Lamadridhttp://lattes.cnpq.br/9679295945027664Fraga, Sarahttp://lattes.cnpq.br/8179821009699942Venturini, Andressa Borin2018-09-13T14:57:20Z2018-09-13T14:57:20Z2018-03-16info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttp://repositorio.ufsm.br/handle/1/14295ark:/26339/0013000015d5hporAttribution-NonCommercial-NoDerivatives 4.0 Internationalinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2018-09-13T14:57:21Zoai:repositorio.ufsm.br:1/14295Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/PUBhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.com||manancial@ufsm.bropendoar:2018-09-13T14:57:21Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false |
| dc.title.none.fl_str_mv |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada Effect of hydrofluoric acid concentration on the fatigue failure load of a cemented feldspathic ceramic |
| title |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada |
| spellingShingle |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada Venturini, Andressa Borin Ácido fluorídrico Carregamento cíclico Cerâmica feldspática Fadiga Tratamento de superfície Cyclic loading Fatigue Feldspathic ceramic Hydrofluoric acid Surface treatment CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
| title_short |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada |
| title_full |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada |
| title_fullStr |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada |
| title_full_unstemmed |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada |
| title_sort |
Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada |
| author |
Venturini, Andressa Borin |
| author_facet |
Venturini, Andressa Borin |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Valandro, Luiz Felipe http://lattes.cnpq.br/0535309012233484 Rippe, Marília Pivetta http://lattes.cnpq.br/3336921465345785 Bergoli, César Dalmolin http://lattes.cnpq.br/4313918234580023 Aurélio, Iana Lamadrid http://lattes.cnpq.br/9679295945027664 Fraga, Sara http://lattes.cnpq.br/8179821009699942 |
| dc.contributor.author.fl_str_mv |
Venturini, Andressa Borin |
| dc.subject.por.fl_str_mv |
Ácido fluorídrico Carregamento cíclico Cerâmica feldspática Fadiga Tratamento de superfície Cyclic loading Fatigue Feldspathic ceramic Hydrofluoric acid Surface treatment CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
| topic |
Ácido fluorídrico Carregamento cíclico Cerâmica feldspática Fadiga Tratamento de superfície Cyclic loading Fatigue Feldspathic ceramic Hydrofluoric acid Surface treatment CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
| description |
The present thesis is composed by two scientific articles that evaluated the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns and discs adhesively cemented to a dentin analogue material (epoxy resin). Therefore, eighty crowns with simplified geometry and eighty feldspathic ceramic discs (Vita Mark II, Vita Zahnfabrik) were randomly allocated, and the intaglio surface of each crown/disc was treated with one of the four surface conditioning methods (n=20): nonetched / control (CTRL), or etched for 60 s with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), or 10% (HF10). The treated ceramic surface received the application of a silane coupling agent. The cementation surface of simplified complete crown preparations and discs (both in epoxy resin) were etched with 10% hydrofluoric acid for 60 s and received a primer coating specific to the cementation system. After the surface treatments, the ceramic crowns and discs were adhesively cemented to the respective prosthetic preparations and epoxy resin discs, which were subjected to cyclic loads in water by a staircase approach (500,000 cycles, 20 Hz). Fatigue failure load data were analyzed by 1-way ANOVA and Tukey’s tests (α= .05). For the ceramic crowns, mean failure loads of groups CTRL (245.0 ± 15.1 N), HF1 (242.5 ± 24.7 N) and HF10 (255.7 ± 53.8 N) were statistically similar (P>.05), while the mean load of the HF5 group (216.7 ± 22.5 N) was significantly lower. In the condition of cemented discs, mean failure load of the HF5 group (255.0 ± 23.0 N) was also significantly lower; HF1 group (301.7 ± 71.0 N) presented intermediate values, and the highest values were achieved in CTRL (351.7 ± 13.4 N) and HF10 (341.7 ± 20.6 N) groups. Etching with 5% hydrofluoric acid had a deleterious effect on the fatigue failure loads of adhesively cemented feldspathic ceramic crowns and discs, while etching with 10% hydrofluoric acid had no negative influence in both tested conditions (crowns and discs). |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-09-13T14:57:20Z 2018-09-13T14:57:20Z 2018-03-16 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
| format |
doctoralThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://repositorio.ufsm.br/handle/1/14295 |
| dc.identifier.dark.fl_str_mv |
ark:/26339/0013000015d5h |
| url |
http://repositorio.ufsm.br/handle/1/14295 |
| identifier_str_mv |
ark:/26339/0013000015d5h |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.rights.driver.fl_str_mv |
Attribution-NonCommercial-NoDerivatives 4.0 International info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Attribution-NonCommercial-NoDerivatives 4.0 International |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidade Federal de Santa Maria Brasil Odontologia UFSM Programa de Pós-Graduação em Ciências Odontológicas Centro de Ciências da Saúde |
| publisher.none.fl_str_mv |
Universidade Federal de Santa Maria Brasil Odontologia UFSM Programa de Pós-Graduação em Ciências Odontológicas Centro de Ciências da Saúde |
| dc.source.none.fl_str_mv |
reponame:Manancial - Repositório Digital da UFSM instname:Universidade Federal de Santa Maria (UFSM) instacron:UFSM |
| instname_str |
Universidade Federal de Santa Maria (UFSM) |
| instacron_str |
UFSM |
| institution |
UFSM |
| reponame_str |
Manancial - Repositório Digital da UFSM |
| collection |
Manancial - Repositório Digital da UFSM |
| repository.name.fl_str_mv |
Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM) |
| repository.mail.fl_str_mv |
atendimento.sib@ufsm.br||tedebc@gmail.com||manancial@ufsm.br |
| _version_ |
1847103645157425152 |