Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada

Bibliographic Details
Main Author: Venturini, Andressa Borin
Publication Date: 2018
Format: Doctoral thesis
Language: por
Source: Manancial - Repositório Digital da UFSM
dARK ID: ark:/26339/0013000015d5h
Download full: http://repositorio.ufsm.br/handle/1/14295
Summary: The present thesis is composed by two scientific articles that evaluated the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns and discs adhesively cemented to a dentin analogue material (epoxy resin). Therefore, eighty crowns with simplified geometry and eighty feldspathic ceramic discs (Vita Mark II, Vita Zahnfabrik) were randomly allocated, and the intaglio surface of each crown/disc was treated with one of the four surface conditioning methods (n=20): nonetched / control (CTRL), or etched for 60 s with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), or 10% (HF10). The treated ceramic surface received the application of a silane coupling agent. The cementation surface of simplified complete crown preparations and discs (both in epoxy resin) were etched with 10% hydrofluoric acid for 60 s and received a primer coating specific to the cementation system. After the surface treatments, the ceramic crowns and discs were adhesively cemented to the respective prosthetic preparations and epoxy resin discs, which were subjected to cyclic loads in water by a staircase approach (500,000 cycles, 20 Hz). Fatigue failure load data were analyzed by 1-way ANOVA and Tukey’s tests (α= .05). For the ceramic crowns, mean failure loads of groups CTRL (245.0 ± 15.1 N), HF1 (242.5 ± 24.7 N) and HF10 (255.7 ± 53.8 N) were statistically similar (P>.05), while the mean load of the HF5 group (216.7 ± 22.5 N) was significantly lower. In the condition of cemented discs, mean failure load of the HF5 group (255.0 ± 23.0 N) was also significantly lower; HF1 group (301.7 ± 71.0 N) presented intermediate values, and the highest values were achieved in CTRL (351.7 ± 13.4 N) and HF10 (341.7 ± 20.6 N) groups. Etching with 5% hydrofluoric acid had a deleterious effect on the fatigue failure loads of adhesively cemented feldspathic ceramic crowns and discs, while etching with 10% hydrofluoric acid had no negative influence in both tested conditions (crowns and discs).
id UFSM_3f327f5eaff24e2a72be409b9b5cb6f4
oai_identifier_str oai:repositorio.ufsm.br:1/14295
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentadaEffect of hydrofluoric acid concentration on the fatigue failure load of a cemented feldspathic ceramicÁcido fluorídricoCarregamento cíclicoCerâmica feldspáticaFadigaTratamento de superfícieCyclic loadingFatigueFeldspathic ceramicHydrofluoric acidSurface treatmentCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAThe present thesis is composed by two scientific articles that evaluated the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns and discs adhesively cemented to a dentin analogue material (epoxy resin). Therefore, eighty crowns with simplified geometry and eighty feldspathic ceramic discs (Vita Mark II, Vita Zahnfabrik) were randomly allocated, and the intaglio surface of each crown/disc was treated with one of the four surface conditioning methods (n=20): nonetched / control (CTRL), or etched for 60 s with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), or 10% (HF10). The treated ceramic surface received the application of a silane coupling agent. The cementation surface of simplified complete crown preparations and discs (both in epoxy resin) were etched with 10% hydrofluoric acid for 60 s and received a primer coating specific to the cementation system. After the surface treatments, the ceramic crowns and discs were adhesively cemented to the respective prosthetic preparations and epoxy resin discs, which were subjected to cyclic loads in water by a staircase approach (500,000 cycles, 20 Hz). Fatigue failure load data were analyzed by 1-way ANOVA and Tukey’s tests (α= .05). For the ceramic crowns, mean failure loads of groups CTRL (245.0 ± 15.1 N), HF1 (242.5 ± 24.7 N) and HF10 (255.7 ± 53.8 N) were statistically similar (P>.05), while the mean load of the HF5 group (216.7 ± 22.5 N) was significantly lower. In the condition of cemented discs, mean failure load of the HF5 group (255.0 ± 23.0 N) was also significantly lower; HF1 group (301.7 ± 71.0 N) presented intermediate values, and the highest values were achieved in CTRL (351.7 ± 13.4 N) and HF10 (341.7 ± 20.6 N) groups. Etching with 5% hydrofluoric acid had a deleterious effect on the fatigue failure loads of adhesively cemented feldspathic ceramic crowns and discs, while etching with 10% hydrofluoric acid had no negative influence in both tested conditions (crowns and discs).Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESA presente tese é composta por dois artigos científicos que avaliaram a influência de diferentes concentrações de ácido fluorídrico na carga para falha em fadiga de coroas e discos de cerâmica feldspática cimentados à um material análogo a dentina (resina epóxi). Para tanto, oitenta coroas com geometria simplificada e oitenta discos de cerâmica feldspática (Vita Mark II, Vita Zahnfabrik) foram divididos aleatoriamente, e a superfície interna de cada coroa/disco foi tratada de acordo com um dos quatro métodos de condicionamento de superfície (n=20): sem condicionamento/controle (CTRL), ou condicionamento por 60 s com diferentes concentrações de ácido fluorídrico: 1% (HF1), 5% (HF5) ou 10% (HF10). A superfície cerâmica tratada recebeu a aplicação de um agente de união silano. A superfície de cimentação dos preparos para coroas totais simplificadas e dos discos (ambos em resina epóxi) foram condicionados com ácido fluorídrico 10% por 60 s seguido da aplicação de uma camada de adesivo específico do sistema de cimentação. Após os tratamentos de superfície, as coroas e discos cerâmicos foram cimentados adesivamente aos respectivos preparos protéticos e discos de resina epóxi, os quais foram submetidos a cargas cíclicas em água pelo método da escada (500.000 ciclos, 20 Hz). Os dados de carga para falha em fadiga foram analisados pela análise de variância (ANOVA-1 fator) e testes de Tukey (α=0,05). Para as coroas cerâmicas, as cargas médias para falha em fadiga dos grupos CTRL (245,0 ± 15,1 N), HF1 (242,5 ± 24,7 N) e HF10 (255,7 ± 53,8 N) foram estatisticamente semelhantes (P>0,05), enquanto que a carga média do grupo HF5 (216,7 ± 22,5 N) foi significativamente inferior. Na condição de discos cimentados, a carga de falha média do grupo HF5 (255,0 ± 23,0 N) também foi significativamente inferior; o grupo HF1 (301,7 ± 71,0 N) apresentou valores intermediários e os valores mais altos foram alcançados nos grupos CTRL (351,7 ± 13,4 N) e HF10 (341,7 ± 20,6 N). O condicionamento com ácido fluorídrico 5% teve um efeito deletério nos valores de carga para falha em fadiga de coroas e discos de cerâmica feldspática cimentados adesivamente, visto que o condicionamento com ácido fluorídrico 10% não teve influência negativa em ambas as condições testadas (coroas e discos).Universidade Federal de Santa MariaBrasilOdontologiaUFSMPrograma de Pós-Graduação em Ciências OdontológicasCentro de Ciências da SaúdeValandro, Luiz Felipehttp://lattes.cnpq.br/0535309012233484Rippe, Marília Pivettahttp://lattes.cnpq.br/3336921465345785Bergoli, César Dalmolinhttp://lattes.cnpq.br/4313918234580023Aurélio, Iana Lamadridhttp://lattes.cnpq.br/9679295945027664Fraga, Sarahttp://lattes.cnpq.br/8179821009699942Venturini, Andressa Borin2018-09-13T14:57:20Z2018-09-13T14:57:20Z2018-03-16info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttp://repositorio.ufsm.br/handle/1/14295ark:/26339/0013000015d5hporAttribution-NonCommercial-NoDerivatives 4.0 Internationalinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2018-09-13T14:57:21Zoai:repositorio.ufsm.br:1/14295Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/PUBhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.com||manancial@ufsm.bropendoar:2018-09-13T14:57:21Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
Effect of hydrofluoric acid concentration on the fatigue failure load of a cemented feldspathic ceramic
title Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
spellingShingle Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
Venturini, Andressa Borin
Ácido fluorídrico
Carregamento cíclico
Cerâmica feldspática
Fadiga
Tratamento de superfície
Cyclic loading
Fatigue
Feldspathic ceramic
Hydrofluoric acid
Surface treatment
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
title_full Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
title_fullStr Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
title_full_unstemmed Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
title_sort Efeito da concentração de ácido fluorídrico na carga para falha em fadiga de uma cerâmica feldspática cimentada
author Venturini, Andressa Borin
author_facet Venturini, Andressa Borin
author_role author
dc.contributor.none.fl_str_mv Valandro, Luiz Felipe
http://lattes.cnpq.br/0535309012233484
Rippe, Marília Pivetta
http://lattes.cnpq.br/3336921465345785
Bergoli, César Dalmolin
http://lattes.cnpq.br/4313918234580023
Aurélio, Iana Lamadrid
http://lattes.cnpq.br/9679295945027664
Fraga, Sara
http://lattes.cnpq.br/8179821009699942
dc.contributor.author.fl_str_mv Venturini, Andressa Borin
dc.subject.por.fl_str_mv Ácido fluorídrico
Carregamento cíclico
Cerâmica feldspática
Fadiga
Tratamento de superfície
Cyclic loading
Fatigue
Feldspathic ceramic
Hydrofluoric acid
Surface treatment
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
topic Ácido fluorídrico
Carregamento cíclico
Cerâmica feldspática
Fadiga
Tratamento de superfície
Cyclic loading
Fatigue
Feldspathic ceramic
Hydrofluoric acid
Surface treatment
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
description The present thesis is composed by two scientific articles that evaluated the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns and discs adhesively cemented to a dentin analogue material (epoxy resin). Therefore, eighty crowns with simplified geometry and eighty feldspathic ceramic discs (Vita Mark II, Vita Zahnfabrik) were randomly allocated, and the intaglio surface of each crown/disc was treated with one of the four surface conditioning methods (n=20): nonetched / control (CTRL), or etched for 60 s with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), or 10% (HF10). The treated ceramic surface received the application of a silane coupling agent. The cementation surface of simplified complete crown preparations and discs (both in epoxy resin) were etched with 10% hydrofluoric acid for 60 s and received a primer coating specific to the cementation system. After the surface treatments, the ceramic crowns and discs were adhesively cemented to the respective prosthetic preparations and epoxy resin discs, which were subjected to cyclic loads in water by a staircase approach (500,000 cycles, 20 Hz). Fatigue failure load data were analyzed by 1-way ANOVA and Tukey’s tests (α= .05). For the ceramic crowns, mean failure loads of groups CTRL (245.0 ± 15.1 N), HF1 (242.5 ± 24.7 N) and HF10 (255.7 ± 53.8 N) were statistically similar (P>.05), while the mean load of the HF5 group (216.7 ± 22.5 N) was significantly lower. In the condition of cemented discs, mean failure load of the HF5 group (255.0 ± 23.0 N) was also significantly lower; HF1 group (301.7 ± 71.0 N) presented intermediate values, and the highest values were achieved in CTRL (351.7 ± 13.4 N) and HF10 (341.7 ± 20.6 N) groups. Etching with 5% hydrofluoric acid had a deleterious effect on the fatigue failure loads of adhesively cemented feldspathic ceramic crowns and discs, while etching with 10% hydrofluoric acid had no negative influence in both tested conditions (crowns and discs).
publishDate 2018
dc.date.none.fl_str_mv 2018-09-13T14:57:20Z
2018-09-13T14:57:20Z
2018-03-16
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/14295
dc.identifier.dark.fl_str_mv ark:/26339/0013000015d5h
url http://repositorio.ufsm.br/handle/1/14295
identifier_str_mv ark:/26339/0013000015d5h
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
Brasil
Odontologia
UFSM
Programa de Pós-Graduação em Ciências Odontológicas
Centro de Ciências da Saúde
publisher.none.fl_str_mv Universidade Federal de Santa Maria
Brasil
Odontologia
UFSM
Programa de Pós-Graduação em Ciências Odontológicas
Centro de Ciências da Saúde
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com||manancial@ufsm.br
_version_ 1847103645157425152