Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency
Main Author: | |
---|---|
Publication Date: | 2021 |
Other Authors: | , , , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da Universidade Federal do Ceará (UFC) |
dARK ID: | ark:/83112/001300001br1z |
Download full: | http://www.repositorio.ufc.br/handle/riufc/69439 |
Summary: | A three-phase soft-switched DC–DC resonant converter with variable frequency to perform the output voltage control is proposed. The open delta-wye connection provides a double output voltage reducing the primary current stress, turns ratio, weight and volume of high-frequency transformer. To achieve high efficiency, an LLC resonant tank is designed so that all switches can perform zero-voltage switching for the entire power range. In order to verify the operating principle of the converter, a design example is described, with the following converter specifications: input voltage 96 V, output voltage 380 V and a switching frequency up to 120 kHz. The feasibility and practicality of the proposed converter are confirmed by experimental results with a 1.5 kW prototype. |
id |
UFC-7_19e1b3a37a9c6d0bc845f7603d3d5556 |
---|---|
oai_identifier_str |
oai:repositorio.ufc.br:riufc/69439 |
network_acronym_str |
UFC-7 |
network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository_id_str |
|
spelling |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequencyA three-phase soft-switched DC–DC resonant converterOutput voltage controlLLC resonant tankA three-phase soft-switched DC–DC resonant converter with variable frequency to perform the output voltage control is proposed. The open delta-wye connection provides a double output voltage reducing the primary current stress, turns ratio, weight and volume of high-frequency transformer. To achieve high efficiency, an LLC resonant tank is designed so that all switches can perform zero-voltage switching for the entire power range. In order to verify the operating principle of the converter, a design example is described, with the following converter specifications: input voltage 96 V, output voltage 380 V and a switching frequency up to 120 kHz. The feasibility and practicality of the proposed converter are confirmed by experimental results with a 1.5 kW prototype.Eletronic Letters2022-11-23T14:01:23Z2022-11-23T14:01:23Z2021info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfOLIVEIRA JR., D. S. et al. Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency. Eletronic Letters, [s.l], v. 57, n. 2, p. 45-95, 2021. DOI: https://doi.org/10.1049/ell2.120431350-911Xhttp://www.repositorio.ufc.br/handle/riufc/69439ark:/83112/001300001br1zSantos, Kristian Pessoa dosPraça, Paulo PeixotoOliveira Filho, Hermínio Miguel deOliveira Júnior, Demercil de SouzaBarreto, Luiz Henrique Silva ColadoHenn, Gustavo Alves de Limainfo:eu-repo/semantics/openAccessengreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFC2023-12-06T17:11:09Zoai:repositorio.ufc.br:riufc/69439Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2023-12-06T17:11:09Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
dc.title.none.fl_str_mv |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
title |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
spellingShingle |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency Santos, Kristian Pessoa dos A three-phase soft-switched DC–DC resonant converter Output voltage control LLC resonant tank |
title_short |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
title_full |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
title_fullStr |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
title_full_unstemmed |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
title_sort |
Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency |
author |
Santos, Kristian Pessoa dos |
author_facet |
Santos, Kristian Pessoa dos Praça, Paulo Peixoto Oliveira Filho, Hermínio Miguel de Oliveira Júnior, Demercil de Souza Barreto, Luiz Henrique Silva Colado Henn, Gustavo Alves de Lima |
author_role |
author |
author2 |
Praça, Paulo Peixoto Oliveira Filho, Hermínio Miguel de Oliveira Júnior, Demercil de Souza Barreto, Luiz Henrique Silva Colado Henn, Gustavo Alves de Lima |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Santos, Kristian Pessoa dos Praça, Paulo Peixoto Oliveira Filho, Hermínio Miguel de Oliveira Júnior, Demercil de Souza Barreto, Luiz Henrique Silva Colado Henn, Gustavo Alves de Lima |
dc.subject.por.fl_str_mv |
A three-phase soft-switched DC–DC resonant converter Output voltage control LLC resonant tank |
topic |
A three-phase soft-switched DC–DC resonant converter Output voltage control LLC resonant tank |
description |
A three-phase soft-switched DC–DC resonant converter with variable frequency to perform the output voltage control is proposed. The open delta-wye connection provides a double output voltage reducing the primary current stress, turns ratio, weight and volume of high-frequency transformer. To achieve high efficiency, an LLC resonant tank is designed so that all switches can perform zero-voltage switching for the entire power range. In order to verify the operating principle of the converter, a design example is described, with the following converter specifications: input voltage 96 V, output voltage 380 V and a switching frequency up to 120 kHz. The feasibility and practicality of the proposed converter are confirmed by experimental results with a 1.5 kW prototype. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021 2022-11-23T14:01:23Z 2022-11-23T14:01:23Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
OLIVEIRA JR., D. S. et al. Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency. Eletronic Letters, [s.l], v. 57, n. 2, p. 45-95, 2021. DOI: https://doi.org/10.1049/ell2.12043 1350-911X http://www.repositorio.ufc.br/handle/riufc/69439 |
dc.identifier.dark.fl_str_mv |
ark:/83112/001300001br1z |
identifier_str_mv |
OLIVEIRA JR., D. S. et al. Comprehensive analysis of a three-phase DC–DC resonant converter with an open delta-wye transformer using variable frequency. Eletronic Letters, [s.l], v. 57, n. 2, p. 45-95, 2021. DOI: https://doi.org/10.1049/ell2.12043 1350-911X ark:/83112/001300001br1z |
url |
http://www.repositorio.ufc.br/handle/riufc/69439 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Eletronic Letters |
publisher.none.fl_str_mv |
Eletronic Letters |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
instname_str |
Universidade Federal do Ceará (UFC) |
instacron_str |
UFC |
institution |
UFC |
reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
_version_ |
1834207820024643584 |