Export Ready — 

Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors

Bibliographic Details
Main Author: Ruschel C.*
Publication Date: 2015
Other Authors: Haupenthal A.*, Jacomel G.F.*, Fontana Hd.eB.*, Santos D.P.*, Scoz R.D.*, Roesler H.*
Format: Article
Language: eng
Source: Repositório Institucional da Udesc
dARK ID: ark:/33523/00130000083q5
Download full: https://repositorio.udesc.br/handle/UDESC/8134
Summary: CONTEXT: Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance.OBJECTIVE: To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force.DESIGN: Validity (concurrent approach) and reliability (test and test-retest approach) study.SETTING: University laboratory.PARTICIPANTS: 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study).MAIN OUTCOME MEASURE: Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study).RESULTS: In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles.CONCLUSIONS: The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.
id UDESC-2_e7b3fb0b585b2bf8d40ac7916168be9c
oai_identifier_str oai:repositorio.udesc.br:UDESC/8134
network_acronym_str UDESC-2
network_name_str Repositório Institucional da Udesc
repository_id_str 6391
spelling Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensorsCONTEXT: Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance.OBJECTIVE: To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force.DESIGN: Validity (concurrent approach) and reliability (test and test-retest approach) study.SETTING: University laboratory.PARTICIPANTS: 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study).MAIN OUTCOME MEASURE: Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study).RESULTS: In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles.CONCLUSIONS: The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.2024-12-06T13:59:20Z2015info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1543-307210.1123/jsr.2013-0122https://repositorio.udesc.br/handle/UDESC/8134ark:/33523/00130000083q5Journal of sport rehabilitationTechnical Notes 11Ruschel C.*Haupenthal A.*Jacomel G.F.*Fontana Hd.eB.*Santos D.P.*Scoz R.D.*Roesler H.*engreponame:Repositório Institucional da Udescinstname:Universidade do Estado de Santa Catarina (UDESC)instacron:UDESCinfo:eu-repo/semantics/openAccess2024-12-07T20:56:31Zoai:repositorio.udesc.br:UDESC/8134Biblioteca Digital de Teses e Dissertaçõeshttps://pergamumweb.udesc.br/biblioteca/index.phpPRIhttps://repositorio-api.udesc.br/server/oai/requestri@udesc.bropendoar:63912024-12-07T20:56:31Repositório Institucional da Udesc - Universidade do Estado de Santa Catarina (UDESC)false
dc.title.none.fl_str_mv Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
title Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
spellingShingle Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
Ruschel C.*
title_short Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
title_full Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
title_fullStr Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
title_full_unstemmed Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
title_sort Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors
author Ruschel C.*
author_facet Ruschel C.*
Haupenthal A.*
Jacomel G.F.*
Fontana Hd.eB.*
Santos D.P.*
Scoz R.D.*
Roesler H.*
author_role author
author2 Haupenthal A.*
Jacomel G.F.*
Fontana Hd.eB.*
Santos D.P.*
Scoz R.D.*
Roesler H.*
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ruschel C.*
Haupenthal A.*
Jacomel G.F.*
Fontana Hd.eB.*
Santos D.P.*
Scoz R.D.*
Roesler H.*
description CONTEXT: Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance.OBJECTIVE: To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force.DESIGN: Validity (concurrent approach) and reliability (test and test-retest approach) study.SETTING: University laboratory.PARTICIPANTS: 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study).MAIN OUTCOME MEASURE: Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study).RESULTS: In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles.CONCLUSIONS: The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.
publishDate 2015
dc.date.none.fl_str_mv 2015
2024-12-06T13:59:20Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv 1543-3072
10.1123/jsr.2013-0122
https://repositorio.udesc.br/handle/UDESC/8134
dc.identifier.dark.fl_str_mv ark:/33523/00130000083q5
identifier_str_mv 1543-3072
10.1123/jsr.2013-0122
ark:/33523/00130000083q5
url https://repositorio.udesc.br/handle/UDESC/8134
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of sport rehabilitation
Technical Notes 11
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Institucional da Udesc
instname:Universidade do Estado de Santa Catarina (UDESC)
instacron:UDESC
instname_str Universidade do Estado de Santa Catarina (UDESC)
instacron_str UDESC
institution UDESC
reponame_str Repositório Institucional da Udesc
collection Repositório Institucional da Udesc
repository.name.fl_str_mv Repositório Institucional da Udesc - Universidade do Estado de Santa Catarina (UDESC)
repository.mail.fl_str_mv ri@udesc.br
_version_ 1842258100941225984