Using an accelerometer for analyzing a reach-to-grasp movement after stroke
| Main Author: | |
|---|---|
| Publication Date: | 2013 |
| Other Authors: | , , , , , |
| Format: | Article |
| Language: | eng |
| Source: | Repositório Institucional da Udesc |
| dARK ID: | ark:/33523/00130000010v1 |
| Download full: | https://repositorio.udesc.br/handle/UDESC/8994 |
Summary: | The purpose of this study was using an accelerometer to access the kinematics of reach-to-grasp movements in subjects with hemiparesis. Eight subjects (59.4 ± 6.9 years old) with chronic hemiparesis (50.9 ± 25.8 months post-stroke) participated in this study. Kinematic assessment was performed using a triaxial accelerometer (EMG Systems, Brazil) attached to the subjects' forearm. Ten reach-to-grasp movements of grabbing a 500ml-size bottle were performed by the subjects with the paretic and the non-paretic upper limbs (ULs). The following spacetemporal variables were calculated and used to compare the paretic and non-paretic ULs: movement time (MT), time to reach the peak velocity, absolute and relative (TPV and TPV%MT), relative deceleration duration (DEC%MT), time to peak acceleration (TPA) and peak hand acceleration (PA). Movements were slower in the paretic UL with increased MT, TPA and DEC. The accelerometer allowed to identify of changes in reaching-to-grasp movements of subjects with hemiparesis. When complex systems are not available, accelerometers can be an alternative to measure UL movements. |
| id |
UDESC-2_062ce7fc3d70d8d4656ec9d629214a97 |
|---|---|
| oai_identifier_str |
oai:repositorio.udesc.br:UDESC/8994 |
| network_acronym_str |
UDESC-2 |
| network_name_str |
Repositório Institucional da Udesc |
| repository_id_str |
6391 |
| spelling |
Using an accelerometer for analyzing a reach-to-grasp movement after strokeThe purpose of this study was using an accelerometer to access the kinematics of reach-to-grasp movements in subjects with hemiparesis. Eight subjects (59.4 ± 6.9 years old) with chronic hemiparesis (50.9 ± 25.8 months post-stroke) participated in this study. Kinematic assessment was performed using a triaxial accelerometer (EMG Systems, Brazil) attached to the subjects' forearm. Ten reach-to-grasp movements of grabbing a 500ml-size bottle were performed by the subjects with the paretic and the non-paretic upper limbs (ULs). The following spacetemporal variables were calculated and used to compare the paretic and non-paretic ULs: movement time (MT), time to reach the peak velocity, absolute and relative (TPV and TPV%MT), relative deceleration duration (DEC%MT), time to peak acceleration (TPA) and peak hand acceleration (PA). Movements were slower in the paretic UL with increased MT, TPA and DEC. The accelerometer allowed to identify of changes in reaching-to-grasp movements of subjects with hemiparesis. When complex systems are not available, accelerometers can be an alternative to measure UL movements.2024-12-06T14:35:53Z2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlep. 746 - 7521980-657410.1590/S1980-65742013000400012https://repositorio.udesc.br/handle/UDESC/8994ark:/33523/00130000010v1Motriz. Revista de Educacao Fisica194Michaelsen S.M.*Gomes R.P.*Marques A.P.*Rodrigues L.C.*Borges Jr. N.G.*Claudino R.*Dos Santos M.J.*engreponame:Repositório Institucional da Udescinstname:Universidade do Estado de Santa Catarina (UDESC)instacron:UDESCinfo:eu-repo/semantics/openAccess2024-12-07T21:00:17Zoai:repositorio.udesc.br:UDESC/8994Biblioteca Digital de Teses e Dissertaçõeshttps://pergamumweb.udesc.br/biblioteca/index.phpPRIhttps://repositorio-api.udesc.br/server/oai/requestri@udesc.bropendoar:63912024-12-07T21:00:17Repositório Institucional da Udesc - Universidade do Estado de Santa Catarina (UDESC)false |
| dc.title.none.fl_str_mv |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| title |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| spellingShingle |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke Michaelsen S.M.* |
| title_short |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| title_full |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| title_fullStr |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| title_full_unstemmed |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| title_sort |
Using an accelerometer for analyzing a reach-to-grasp movement after stroke |
| author |
Michaelsen S.M.* |
| author_facet |
Michaelsen S.M.* Gomes R.P.* Marques A.P.* Rodrigues L.C.* Borges Jr. N.G.* Claudino R.* Dos Santos M.J.* |
| author_role |
author |
| author2 |
Gomes R.P.* Marques A.P.* Rodrigues L.C.* Borges Jr. N.G.* Claudino R.* Dos Santos M.J.* |
| author2_role |
author author author author author author |
| dc.contributor.author.fl_str_mv |
Michaelsen S.M.* Gomes R.P.* Marques A.P.* Rodrigues L.C.* Borges Jr. N.G.* Claudino R.* Dos Santos M.J.* |
| description |
The purpose of this study was using an accelerometer to access the kinematics of reach-to-grasp movements in subjects with hemiparesis. Eight subjects (59.4 ± 6.9 years old) with chronic hemiparesis (50.9 ± 25.8 months post-stroke) participated in this study. Kinematic assessment was performed using a triaxial accelerometer (EMG Systems, Brazil) attached to the subjects' forearm. Ten reach-to-grasp movements of grabbing a 500ml-size bottle were performed by the subjects with the paretic and the non-paretic upper limbs (ULs). The following spacetemporal variables were calculated and used to compare the paretic and non-paretic ULs: movement time (MT), time to reach the peak velocity, absolute and relative (TPV and TPV%MT), relative deceleration duration (DEC%MT), time to peak acceleration (TPA) and peak hand acceleration (PA). Movements were slower in the paretic UL with increased MT, TPA and DEC. The accelerometer allowed to identify of changes in reaching-to-grasp movements of subjects with hemiparesis. When complex systems are not available, accelerometers can be an alternative to measure UL movements. |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013 2024-12-06T14:35:53Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
1980-6574 10.1590/S1980-65742013000400012 https://repositorio.udesc.br/handle/UDESC/8994 |
| dc.identifier.dark.fl_str_mv |
ark:/33523/00130000010v1 |
| identifier_str_mv |
1980-6574 10.1590/S1980-65742013000400012 ark:/33523/00130000010v1 |
| url |
https://repositorio.udesc.br/handle/UDESC/8994 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
Motriz. Revista de Educacao Fisica 19 4 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
p. 746 - 752 |
| dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Udesc instname:Universidade do Estado de Santa Catarina (UDESC) instacron:UDESC |
| instname_str |
Universidade do Estado de Santa Catarina (UDESC) |
| instacron_str |
UDESC |
| institution |
UDESC |
| reponame_str |
Repositório Institucional da Udesc |
| collection |
Repositório Institucional da Udesc |
| repository.name.fl_str_mv |
Repositório Institucional da Udesc - Universidade do Estado de Santa Catarina (UDESC) |
| repository.mail.fl_str_mv |
ri@udesc.br |
| _version_ |
1848168310266396672 |