Export Ready — 

Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo

Bibliographic Details
Main Author: Veiga, Elaine Cristina Tognoli da
Publication Date: 2013
Format: Master thesis
Language: por
Source: Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic
Download full: https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/66450
Summary: Dissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic, Campinas - SP.
id SLMC-1_eae8a2bc3b533b5793339c2ed9511716
oai_identifier_str oai:prima.com.br:66450
network_acronym_str SLMC-1
network_name_str Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic
repository_id_str
spelling Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocoloImplante dentárioPrótese dentária fixada por implanteTécnica de moldagem odontológicaDissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic, Campinas - SP.Nesse estudo avaliou-se a precisão de duas técnicas diretas de moldagem sobre implantes para prótese tipo protocolo. Foram avaliados e comparados os seguintes aspectos de ambas as técnicas: tempo de procedimento e presença de gap entre os mini pilares dos implantes e a supraestrutura. Dois grupos foram formados: grupo 1, técnica preconizada por Branemark et al. (1985), transferentes quadrados unidos com fio dental e resina acrílica, com moldeira aberta e grupo 2, transferentes quadrados, moldeira plástica com sistema de tela fraturável e resina acrílica distribuída em cima da moldeira unindo os transferentes e estabelecendo uma união rígida entre eles (Migliorança, 2008). Foram realizados quinze corpos de prova para cada grupo (n=15). Todas as moldagens foram realizadas com silicone de condensação. Foi confeccionado um modelo mestre, em resina acrílica, com quatro implantes de hexágono externo, paralelos entre si. Sobre os implantes foram instalados os intermediários (mini pilares cônicos) e confeccionada uma estrutura metálica mestre com adaptação passiva. Os análogos dos implantes nos modelos foram enumerados de 1 a 4, começando pelo mais distal da direita para a esquerda. Foram realizadas três sequências de avaliação. Na primeira sequência os 4 parafusos foram colocados na estrutura metálica. Na segunda sequência foi colocado um parafuso no análogo 1 e na terceira sequência foi colocado um parafuso no análogo 4. Em todas as sequências, as adaptações entre os mini pilares e a estrutura metálica, foram mensuradas tanto pela vestibular como pela lingual, do análogo 1 ao 4, por meio de inspeção visual, sondagem da linha de união com explorador e Análise Computadorizada das Fotografias Digitais (ACFD). Os tempos clínicos mensurados para execução dos procedimentos de moldagem foram submetidos ao teste t de Student e demonstrou que houve diferença significativa entre os tempos despendidos para execução das técnicas de moldagem, indicando que o tempo foi menor para o Grupo 2 (p<0,001). Testes exatos de Fisher foram aplicados para verificar se existiu diferença entre ambas as técnicas quanto à proporção de implantes que apresentaram gap em cada uma das três sequências de avaliação do posicionamento da supraestrutura sobre o modelo e indicaram que não diferiram significativamente entre si (p = 1,000). Pode-se concluir que o tempo de moldagem com a técnica de moldeira com tela fraturável foi menor que na técnica descrita por Branemark et al. (1985) e que em relação à presença de gap, os resultados apresentaram-se semelhantes. Palavras-chave: Prótese sobre implante. Moldagem de transferência. Precisão. Técnica de moldagem. In this study we evaluated the accuracy of two impression techniques for implant prosthesis protocol type. The following aspects of both techniques were evaluated and compared: procedure time and presence of gap between the mini implant's pillars and the superstructure. Two groups were formed: group 1, technique recommended by Branemark et al. (1985), squared transfer together with dental floss and acrylic resin, with open tray and group 2, squared transfer, plastic tray with screen system fractured and acrylic resin distributed on the tray joining the transferees and establishing a rigid connection between them (Migliorança, 2008). Fifteen specimens for each group were performed (n=15). All casts were made with condensation silicone. A master model was made in acrylic resin, with four external hex implants, parallel to each other. About the implants were installed intermediaries (Mini pillars conical) and made a metal superstructure master with passive adaptation. The implant's analogs in the models were numbered from 1 to 4, starting with the most distal from right to left. Three sequences of evaluation were performed. In the first sequence the 4 screws were placed in the metal structure. In the second sequence was placed a screw in the analog 1 and in the third sequence was placed one screw in the analog 4. In all sequences, the adaptations among mini pillars and metal structure were measured by both, the vestibular and the lingual, from analog 1 to 4, by visual inspection, probing the line of union with explorer and Computerized Analysis of Digital Photography (ACFD). The measured clinical times for execution of molding procedures were submitted to "Student's t test" and showed that there was significant difference between the time spent for execution of molding techniques, indicating that the time was shorter in Group 2 (p <0.001). "Fisher's exact tests" were applied to check whether there was difference between both techniques as the proportion of implants that had a gap in each of the three sequences assessing the positioning of the superstructure upon the model and indicate that not differ significantly between them (p = 1.000). It can be concluded that the time of the molding with the technique of tray with fractured screen was lower than the technique described by Branemark et al. (1985) and in the presence of a gap, the results were similar. Keywords: Implant prosthesis. Transfer Impression. Accuracy. Impression technique.Brito Júnior, Rui Barbosa deCentro de Pesquisas Odontológicas São Leopoldo MandicVeiga, Elaine Cristina Tognoli da2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf73 f. : il.https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/66450https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/66450porreponame:Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandicinstname:Faculdade São Leopoldo Mandicinstacron:SLMANDICinfo:eu-repo/semantics/openAccess2022-08-23T08:04:40Zoai:prima.com.br:66450Biblioteca Digital de Teses e DissertaçõesPRIhttps://biblioteca.slmandic.edu.br/biblioteca/oai/oai.aspsamanta.capeletto@slmandic.edu.bropendoar:2022-08-23T08:04:40Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic - Faculdade São Leopoldo Mandicfalse
dc.title.none.fl_str_mv Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
title Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
spellingShingle Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
Veiga, Elaine Cristina Tognoli da
Implante dentário
Prótese dentária fixada por implante
Técnica de moldagem odontológica
title_short Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
title_full Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
title_fullStr Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
title_full_unstemmed Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
title_sort Estudo comparativo de duas técnicas de moldagem para prótese sobre implante tipo protocolo
author Veiga, Elaine Cristina Tognoli da
author_facet Veiga, Elaine Cristina Tognoli da
author_role author
dc.contributor.none.fl_str_mv Brito Júnior, Rui Barbosa de
Centro de Pesquisas Odontológicas São Leopoldo Mandic
dc.contributor.author.fl_str_mv Veiga, Elaine Cristina Tognoli da
dc.subject.por.fl_str_mv Implante dentário
Prótese dentária fixada por implante
Técnica de moldagem odontológica
topic Implante dentário
Prótese dentária fixada por implante
Técnica de moldagem odontológica
description Dissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic, Campinas - SP.
publishDate 2013
dc.date.none.fl_str_mv 2013
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/66450
url https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/66450
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/66450
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
73 f. : il.
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic
instname:Faculdade São Leopoldo Mandic
instacron:SLMANDIC
instname_str Faculdade São Leopoldo Mandic
instacron_str SLMANDIC
institution SLMANDIC
reponame_str Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic
collection Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic - Faculdade São Leopoldo Mandic
repository.mail.fl_str_mv samanta.capeletto@slmandic.edu.br
_version_ 1837815798131851264