Two-staged treatment for advanced keratoconus in children
Main Author: | |
---|---|
Publication Date: | 2018 |
Other Authors: | , |
Format: | Report |
Language: | eng |
Source: | Revista Brasileira de Oftalmologia (Online) |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300159 |
Summary: | Abstract We present a case of a 12-year-old patient with advanced keratoconus in both eyes who received a two-staged treatment in the right eye (OD) to decrease keratoconus progression rate and rehabilitate patient’s vision. At the initial clinical examination, visual acuity without correction in OD was count fingers; cycloplegic refraction was -22.00 - 7,50 x 100° = 20/400; corneal topography demonstrated a curvature of 64.28 x 105° / 55.38 x 15°; and tomography (WaveLight - Allegro Oculyzer) demonstrated a curvature of 68.1 x 114° / 63.3 x 163° Q = -2.67. Initially, the patient received an intrastromal ring segment (210 mm / 200 µm) slightly off center to avoid the thinnest part of the cornea. Six months later a phakic lens was implanted in the anterior chamber. At the follow-up visit 13 months after phakic lens implantation (19 months after ring implantation), visual acuity in OD was 20/20 without correction; cycloplegic refraction was -0.50 -0.75 x 180o = 20/20; and corneal topography showed keratometry of 63.22 x 44o / 61.10 x 134o. The results demonstrated that the associated procedures were successful in decreasing irregular astigmatism and markedly improving patient’s uncorrected visual acuity in OD, postponing the need for corneal transplantation to a more suitable age, if required. |
id |
SBO-1_17dbadf5d56e41d4312b04bd27e01cdf |
---|---|
oai_identifier_str |
oai:scielo:S0034-72802018000300159 |
network_acronym_str |
SBO-1 |
network_name_str |
Revista Brasileira de Oftalmologia (Online) |
repository_id_str |
|
spelling |
Two-staged treatment for advanced keratoconus in childrenKeratoconus/surgeryCorneaImplantsIntraocular lensesCase reportsAbstract We present a case of a 12-year-old patient with advanced keratoconus in both eyes who received a two-staged treatment in the right eye (OD) to decrease keratoconus progression rate and rehabilitate patient’s vision. At the initial clinical examination, visual acuity without correction in OD was count fingers; cycloplegic refraction was -22.00 - 7,50 x 100° = 20/400; corneal topography demonstrated a curvature of 64.28 x 105° / 55.38 x 15°; and tomography (WaveLight - Allegro Oculyzer) demonstrated a curvature of 68.1 x 114° / 63.3 x 163° Q = -2.67. Initially, the patient received an intrastromal ring segment (210 mm / 200 µm) slightly off center to avoid the thinnest part of the cornea. Six months later a phakic lens was implanted in the anterior chamber. At the follow-up visit 13 months after phakic lens implantation (19 months after ring implantation), visual acuity in OD was 20/20 without correction; cycloplegic refraction was -0.50 -0.75 x 180o = 20/20; and corneal topography showed keratometry of 63.22 x 44o / 61.10 x 134o. The results demonstrated that the associated procedures were successful in decreasing irregular astigmatism and markedly improving patient’s uncorrected visual acuity in OD, postponing the need for corneal transplantation to a more suitable age, if required.Sociedade Brasileira de Oftalmologia2018-06-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300159Revista Brasileira de Oftalmologia v.77 n.3 2018reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.5935/0034-7280.20180036info:eu-repo/semantics/openAccessAlmodin,Edna MottaCamin,Flavia Motta AlmodinColallilo,Juliana Motta Almodineng2018-06-20T00:00:00Zoai:scielo:S0034-72802018000300159Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2018-06-20T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false |
dc.title.none.fl_str_mv |
Two-staged treatment for advanced keratoconus in children |
title |
Two-staged treatment for advanced keratoconus in children |
spellingShingle |
Two-staged treatment for advanced keratoconus in children Almodin,Edna Motta Keratoconus/surgery Cornea Implants Intraocular lenses Case reports |
title_short |
Two-staged treatment for advanced keratoconus in children |
title_full |
Two-staged treatment for advanced keratoconus in children |
title_fullStr |
Two-staged treatment for advanced keratoconus in children |
title_full_unstemmed |
Two-staged treatment for advanced keratoconus in children |
title_sort |
Two-staged treatment for advanced keratoconus in children |
author |
Almodin,Edna Motta |
author_facet |
Almodin,Edna Motta Camin,Flavia Motta Almodin Colallilo,Juliana Motta Almodin |
author_role |
author |
author2 |
Camin,Flavia Motta Almodin Colallilo,Juliana Motta Almodin |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Almodin,Edna Motta Camin,Flavia Motta Almodin Colallilo,Juliana Motta Almodin |
dc.subject.por.fl_str_mv |
Keratoconus/surgery Cornea Implants Intraocular lenses Case reports |
topic |
Keratoconus/surgery Cornea Implants Intraocular lenses Case reports |
description |
Abstract We present a case of a 12-year-old patient with advanced keratoconus in both eyes who received a two-staged treatment in the right eye (OD) to decrease keratoconus progression rate and rehabilitate patient’s vision. At the initial clinical examination, visual acuity without correction in OD was count fingers; cycloplegic refraction was -22.00 - 7,50 x 100° = 20/400; corneal topography demonstrated a curvature of 64.28 x 105° / 55.38 x 15°; and tomography (WaveLight - Allegro Oculyzer) demonstrated a curvature of 68.1 x 114° / 63.3 x 163° Q = -2.67. Initially, the patient received an intrastromal ring segment (210 mm / 200 µm) slightly off center to avoid the thinnest part of the cornea. Six months later a phakic lens was implanted in the anterior chamber. At the follow-up visit 13 months after phakic lens implantation (19 months after ring implantation), visual acuity in OD was 20/20 without correction; cycloplegic refraction was -0.50 -0.75 x 180o = 20/20; and corneal topography showed keratometry of 63.22 x 44o / 61.10 x 134o. The results demonstrated that the associated procedures were successful in decreasing irregular astigmatism and markedly improving patient’s uncorrected visual acuity in OD, postponing the need for corneal transplantation to a more suitable age, if required. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/report |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
report |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300159 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300159 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0034-7280.20180036 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Oftalmologia v.77 n.3 2018 reponame:Revista Brasileira de Oftalmologia (Online) instname:Sociedade Brasileira de Oftalmologia (SBO) instacron:SBO |
instname_str |
Sociedade Brasileira de Oftalmologia (SBO) |
instacron_str |
SBO |
institution |
SBO |
reponame_str |
Revista Brasileira de Oftalmologia (Online) |
collection |
Revista Brasileira de Oftalmologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO) |
repository.mail.fl_str_mv |
sob@sboportal.org.br||rbo@sboportal.org.br |
_version_ |
1752122338285977600 |