Anesthetic experimental device for small animal

Bibliographic Details
Main Author: Vivas,Luiz Alfredo de Magalhães
Publication Date: 2007
Other Authors: Jamel,Nelson, Refinetti,Ricardo Antonio, Silva,Luis Felipe da, Rodrigues,Lígia Villela, Silva,Paulo Cesar, Schanaider,Alberto
Format: Article
Language: eng
Source: Acta Cirúrgica Brasileira (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012
Summary: PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.
id SBDPC-1_39918147a0b4af8a1a368ba4c46b6247
oai_identifier_str oai:scielo:S0102-86502007000300012
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Anesthetic experimental device for small animalAnesthesia, InhalationEquipment DesignExperimental DevelopmentRatsPURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2007-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012Acta Cirúrgica Brasileira v.22 n.3 2007reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502007000300012info:eu-repo/semantics/openAccessVivas,Luiz Alfredo de MagalhãesJamel,NelsonRefinetti,Ricardo AntonioSilva,Luis Felipe daRodrigues,Lígia VillelaSilva,Paulo CesarSchanaider,Albertoeng2007-05-24T00:00:00Zoai:scielo:S0102-86502007000300012Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2007-05-24T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Anesthetic experimental device for small animal
title Anesthetic experimental device for small animal
spellingShingle Anesthetic experimental device for small animal
Vivas,Luiz Alfredo de Magalhães
Anesthesia, Inhalation
Equipment Design
Experimental Development
Rats
title_short Anesthetic experimental device for small animal
title_full Anesthetic experimental device for small animal
title_fullStr Anesthetic experimental device for small animal
title_full_unstemmed Anesthetic experimental device for small animal
title_sort Anesthetic experimental device for small animal
author Vivas,Luiz Alfredo de Magalhães
author_facet Vivas,Luiz Alfredo de Magalhães
Jamel,Nelson
Refinetti,Ricardo Antonio
Silva,Luis Felipe da
Rodrigues,Lígia Villela
Silva,Paulo Cesar
Schanaider,Alberto
author_role author
author2 Jamel,Nelson
Refinetti,Ricardo Antonio
Silva,Luis Felipe da
Rodrigues,Lígia Villela
Silva,Paulo Cesar
Schanaider,Alberto
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Vivas,Luiz Alfredo de Magalhães
Jamel,Nelson
Refinetti,Ricardo Antonio
Silva,Luis Felipe da
Rodrigues,Lígia Villela
Silva,Paulo Cesar
Schanaider,Alberto
dc.subject.por.fl_str_mv Anesthesia, Inhalation
Equipment Design
Experimental Development
Rats
topic Anesthesia, Inhalation
Equipment Design
Experimental Development
Rats
description PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.
publishDate 2007
dc.date.none.fl_str_mv 2007-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-86502007000300012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.22 n.3 2007
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126438654345216