Anesthetic experimental device for small animal
Main Author: | |
---|---|
Publication Date: | 2007 |
Other Authors: | , , , , , |
Format: | Article |
Language: | eng |
Source: | Acta Cirúrgica Brasileira (Online) |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012 |
Summary: | PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research. |
id |
SBDPC-1_39918147a0b4af8a1a368ba4c46b6247 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502007000300012 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Anesthetic experimental device for small animalAnesthesia, InhalationEquipment DesignExperimental DevelopmentRatsPURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2007-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012Acta Cirúrgica Brasileira v.22 n.3 2007reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502007000300012info:eu-repo/semantics/openAccessVivas,Luiz Alfredo de MagalhãesJamel,NelsonRefinetti,Ricardo AntonioSilva,Luis Felipe daRodrigues,Lígia VillelaSilva,Paulo CesarSchanaider,Albertoeng2007-05-24T00:00:00Zoai:scielo:S0102-86502007000300012Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2007-05-24T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Anesthetic experimental device for small animal |
title |
Anesthetic experimental device for small animal |
spellingShingle |
Anesthetic experimental device for small animal Vivas,Luiz Alfredo de Magalhães Anesthesia, Inhalation Equipment Design Experimental Development Rats |
title_short |
Anesthetic experimental device for small animal |
title_full |
Anesthetic experimental device for small animal |
title_fullStr |
Anesthetic experimental device for small animal |
title_full_unstemmed |
Anesthetic experimental device for small animal |
title_sort |
Anesthetic experimental device for small animal |
author |
Vivas,Luiz Alfredo de Magalhães |
author_facet |
Vivas,Luiz Alfredo de Magalhães Jamel,Nelson Refinetti,Ricardo Antonio Silva,Luis Felipe da Rodrigues,Lígia Villela Silva,Paulo Cesar Schanaider,Alberto |
author_role |
author |
author2 |
Jamel,Nelson Refinetti,Ricardo Antonio Silva,Luis Felipe da Rodrigues,Lígia Villela Silva,Paulo Cesar Schanaider,Alberto |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Vivas,Luiz Alfredo de Magalhães Jamel,Nelson Refinetti,Ricardo Antonio Silva,Luis Felipe da Rodrigues,Lígia Villela Silva,Paulo Cesar Schanaider,Alberto |
dc.subject.por.fl_str_mv |
Anesthesia, Inhalation Equipment Design Experimental Development Rats |
topic |
Anesthesia, Inhalation Equipment Design Experimental Development Rats |
description |
PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes), and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300012 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0102-86502007000300012 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.22 n.3 2007 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126438654345216 |