Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , |
Tipo de documento: | Relatório |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Anestesiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000500549 |
Resumo: | Abstract Myasthenia Gravis (MG) is an autoimmune disease characterized by weakness and fatigability of skeletal muscles, with improvement following rest. It is a disease of great significance to the anesthesiologist because it affects the neuromuscular junction. Robotic thymectomy has come up in recent times due to the minimally invasive nature and its advantages. This presents a new set of challenges for the anesthesia team, and here we present the various anesthesia considerations and perioperative management in a series of 20 patients who underwent robotic thymectomy. As it is a recent upcoming procedure, there is a paucity of literature on this topic, and most of the available literature talks about One-Lung Ventilation (OLV) and thoracic epidurals. To our notice, this is the first literature without the use of OLV and thoracic epidural for the management of robotic thymectomy. |
id |
SBA-1_ec7477a2337c333b041cf0249ce2fba2 |
---|---|
oai_identifier_str |
oai:scielo:S0034-70942020000500549 |
network_acronym_str |
SBA-1 |
network_name_str |
Revista Brasileira de Anestesiologia (Online) |
repository_id_str |
|
spelling |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravisMyasthenia GravisNeuromuscular blockadeRobotic thymectomyAbstract Myasthenia Gravis (MG) is an autoimmune disease characterized by weakness and fatigability of skeletal muscles, with improvement following rest. It is a disease of great significance to the anesthesiologist because it affects the neuromuscular junction. Robotic thymectomy has come up in recent times due to the minimally invasive nature and its advantages. This presents a new set of challenges for the anesthesia team, and here we present the various anesthesia considerations and perioperative management in a series of 20 patients who underwent robotic thymectomy. As it is a recent upcoming procedure, there is a paucity of literature on this topic, and most of the available literature talks about One-Lung Ventilation (OLV) and thoracic epidurals. To our notice, this is the first literature without the use of OLV and thoracic epidural for the management of robotic thymectomy.Sociedade Brasileira de Anestesiologia2020-10-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000500549Revista Brasileira de Anestesiologia v.70 n.5 2020reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2020.05.005info:eu-repo/semantics/openAccessPal,AtishGogia,VikasMehra,Chetaneng2020-12-16T00:00:00Zoai:scielo:S0034-70942020000500549Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2020-12-16T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false |
dc.title.none.fl_str_mv |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
title |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
spellingShingle |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis Pal,Atish Myasthenia Gravis Neuromuscular blockade Robotic thymectomy |
title_short |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
title_full |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
title_fullStr |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
title_full_unstemmed |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
title_sort |
Perioperative challenges and neuromuscular blockade concerns in robotic thymectomy for myasthenia gravis |
author |
Pal,Atish |
author_facet |
Pal,Atish Gogia,Vikas Mehra,Chetan |
author_role |
author |
author2 |
Gogia,Vikas Mehra,Chetan |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Pal,Atish Gogia,Vikas Mehra,Chetan |
dc.subject.por.fl_str_mv |
Myasthenia Gravis Neuromuscular blockade Robotic thymectomy |
topic |
Myasthenia Gravis Neuromuscular blockade Robotic thymectomy |
description |
Abstract Myasthenia Gravis (MG) is an autoimmune disease characterized by weakness and fatigability of skeletal muscles, with improvement following rest. It is a disease of great significance to the anesthesiologist because it affects the neuromuscular junction. Robotic thymectomy has come up in recent times due to the minimally invasive nature and its advantages. This presents a new set of challenges for the anesthesia team, and here we present the various anesthesia considerations and perioperative management in a series of 20 patients who underwent robotic thymectomy. As it is a recent upcoming procedure, there is a paucity of literature on this topic, and most of the available literature talks about One-Lung Ventilation (OLV) and thoracic epidurals. To our notice, this is the first literature without the use of OLV and thoracic epidural for the management of robotic thymectomy. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/report |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
report |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000500549 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000500549 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjane.2020.05.005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Anestesiologia v.70 n.5 2020 reponame:Revista Brasileira de Anestesiologia (Online) instname:Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA |
instname_str |
Sociedade Brasileira de Anestesiologia (SBA) |
instacron_str |
SBA |
institution |
SBA |
reponame_str |
Revista Brasileira de Anestesiologia (Online) |
collection |
Revista Brasileira de Anestesiologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA) |
repository.mail.fl_str_mv |
||sba2000@openlink.com.br |
_version_ |
1752126630858326016 |