A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report

Bibliographic Details
Main Author: Powell,Karlyn
Publication Date: 2020
Format: Report
Language: eng
Source: Revista Brasileira de Anestesiologia (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000200175
Summary: Abstract Background: The Argon Beam Coagulator (ABC) achieves hemostasis but has potential complications in the form of argon gas embolisms. Risk factors for embolisms have been identified and ABC manufacturers have developed guidelines for usage of the device to prevent embolism development. Case report: A 49 year-old male with history of recurrent cholangiocarcinoma status post resection presented for resection of a cutaneous biliary fistula. Shortly after initial use of the ABC, the patient underwent cardiac arrest. After resuscitation, air bubbles were observed in the left ventricle via Transesophageal Echo (TEE). Conclusion: Although argon embolisms have been described more commonly during laparoscopies, this patient most likely experienced an argon gas embolism during an open resection of a cutaneous biliary fistula via the biliary tract or vein with possible transpulmonary passage of the embolism. Consequently, a high degree of suspicion should be maintained for an argon gas embolism during ABC use in laparoscopic, open, and cutaneous surgeries.
id SBA-1_caf77ec8746a795f5363e752898aff06
oai_identifier_str oai:scielo:S0034-70942020000200175
network_acronym_str SBA-1
network_name_str Revista Brasileira de Anestesiologia (Online)
repository_id_str
spelling A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case reportArgon beam coagulation systemVenous gas embolismPulmonary gas embolismAbstract Background: The Argon Beam Coagulator (ABC) achieves hemostasis but has potential complications in the form of argon gas embolisms. Risk factors for embolisms have been identified and ABC manufacturers have developed guidelines for usage of the device to prevent embolism development. Case report: A 49 year-old male with history of recurrent cholangiocarcinoma status post resection presented for resection of a cutaneous biliary fistula. Shortly after initial use of the ABC, the patient underwent cardiac arrest. After resuscitation, air bubbles were observed in the left ventricle via Transesophageal Echo (TEE). Conclusion: Although argon embolisms have been described more commonly during laparoscopies, this patient most likely experienced an argon gas embolism during an open resection of a cutaneous biliary fistula via the biliary tract or vein with possible transpulmonary passage of the embolism. Consequently, a high degree of suspicion should be maintained for an argon gas embolism during ABC use in laparoscopic, open, and cutaneous surgeries.Sociedade Brasileira de Anestesiologia2020-04-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000200175Revista Brasileira de Anestesiologia v.70 n.2 2020reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2019.12.003info:eu-repo/semantics/openAccessPowell,Karlyneng2020-08-07T00:00:00Zoai:scielo:S0034-70942020000200175Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2020-08-07T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false
dc.title.none.fl_str_mv A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
title A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
spellingShingle A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
Powell,Karlyn
Argon beam coagulation system
Venous gas embolism
Pulmonary gas embolism
title_short A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
title_full A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
title_fullStr A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
title_full_unstemmed A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
title_sort A probable fatal argon gas embolism during resection of a cutaneous biliary fistula - a case report
author Powell,Karlyn
author_facet Powell,Karlyn
author_role author
dc.contributor.author.fl_str_mv Powell,Karlyn
dc.subject.por.fl_str_mv Argon beam coagulation system
Venous gas embolism
Pulmonary gas embolism
topic Argon beam coagulation system
Venous gas embolism
Pulmonary gas embolism
description Abstract Background: The Argon Beam Coagulator (ABC) achieves hemostasis but has potential complications in the form of argon gas embolisms. Risk factors for embolisms have been identified and ABC manufacturers have developed guidelines for usage of the device to prevent embolism development. Case report: A 49 year-old male with history of recurrent cholangiocarcinoma status post resection presented for resection of a cutaneous biliary fistula. Shortly after initial use of the ABC, the patient underwent cardiac arrest. After resuscitation, air bubbles were observed in the left ventricle via Transesophageal Echo (TEE). Conclusion: Although argon embolisms have been described more commonly during laparoscopies, this patient most likely experienced an argon gas embolism during an open resection of a cutaneous biliary fistula via the biliary tract or vein with possible transpulmonary passage of the embolism. Consequently, a high degree of suspicion should be maintained for an argon gas embolism during ABC use in laparoscopic, open, and cutaneous surgeries.
publishDate 2020
dc.date.none.fl_str_mv 2020-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/report
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format report
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000200175
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000200175
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjane.2019.12.003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
dc.source.none.fl_str_mv Revista Brasileira de Anestesiologia v.70 n.2 2020
reponame:Revista Brasileira de Anestesiologia (Online)
instname:Sociedade Brasileira de Anestesiologia (SBA)
instacron:SBA
instname_str Sociedade Brasileira de Anestesiologia (SBA)
instacron_str SBA
institution SBA
reponame_str Revista Brasileira de Anestesiologia (Online)
collection Revista Brasileira de Anestesiologia (Online)
repository.name.fl_str_mv Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)
repository.mail.fl_str_mv ||sba2000@openlink.com.br
_version_ 1752126630593036288