Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação

Bibliographic Details
Main Author: João, Iola Marisa Vicente Cardoso
Publication Date: 2009
Format: Master thesis
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10451/5379
Summary: Tese de mestrado, Biofísica (Física Médica e Engenharia Biomédica), Universidade de Lisboa, Faculdade de Ciências, 2009
id RCAP_fe0c06fc5e36f8f59eec0462f8a2c812
oai_identifier_str oai:repositorio.ulisboa.pt:10451/5379
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementaçãoIMRTImplementaçãoControlo de qualidadeAcelerador linearIrradiação dinâmicaTeses de mestrado - 2009Tese de mestrado, Biofísica (Física Médica e Engenharia Biomédica), Universidade de Lisboa, Faculdade de Ciências, 2009Em Radioterapia a utilização de técnicas de tratamento com elevada conformação resultam da evolução técnica e tecnológica dos últimos anos. Pode destacar-se o desenvolvimento de novos algoritmos de cálculo de dose e a integração de novos dispositivos como o caso dos colimadores multilâminas com irradiações dinâmicas. Salienta-se também a possibilidade de aquisição de imagens com novas ferramentas e com uma menor contribuição de dose para o doente. A radioterapia de intensidade modulada (IMRT) é uma dessas técnicas que tem sido, nos últimos anos, mundialmente aplicada. Para a utilização clínica desta técnica, que permite obter distribuições de dose com uma preservação maior dos órgãos nobres ou a administração de doses mais elevadas aos volumes alvo, foi necessário consultar as indicações fornecidas pelos organismos internacionais e analisar as experiências de outros grupos de trabalho. Este trabalho sintetiza uma experiência pioneira em Portugal que resultou na implementação da Radioterapia de Intensidade Modulada Guiada por Imagem (IMRT-IGRT) com a apresentação dos principais resultados obtidos para tratamentos de neoplasias prostáticas e a descrição dos procedimentos de trabalho aplicados. Foi utilizado um Acelerador Linear Trilogy, Varian®, o Sistema de elaboração de planimetrias Eclipse® com o seu módulo de Planeamento Inverso Hélios®, um sistema dosimetria portal e outro de dosimetria fotográfica composto por películas ERD2, Kodak®, software de análise RIT113® e scanner Vidar®. Foram ainda utilizados electrómetros, câmaras de ionização, e 2 fantomas (antropomórfico e de placas). Foram elaborados os procedimentos referentes às várias actividades, desde as verificações iniciais antes da implementação da técnica de IMRT até à realização do tratamento diário passando pela aquisição de dados, validação da referida técnica, posicionamento e imobilização dos doentes, elaboração da planimetria e execução do controlo da qualidade. A aplicação dos procedimentos descritos permitiu a obtenção de valores de dose administrados aos doentes dentro dos critérios predefinidos.The application of high conformal treatment techniques in Radiotherapy has only been possible with the developments that occurred in the last decades as a result of a technical and technological evolution without precedent. It is possible to highlight the development of new calculation algorithms, the inclusion of new devices such the MLCs with dynamic irradiation and the image acquisition equipments with new tools and with a decrease in the dose received by normal tissues. IMRT is one of those new techniques that have been widely implemented across the world allowing dose distributions with higher protection of critical structures or the application of higher dose values to the target volumes in order to try to achieve better local control. For the implementation and application of this technique it was necessary to consult the major international guidelines and to analyze the experience that has been published by other work groups. The aim of this work is to describe one of the first experiences in the utilization of an IMRT-IGRT treatment in Portugal and describe the procedures that were applied with the goal to create guidelines to help other workgroups implement IMRT. The activity has been done using a Trilogy Linear Accelerator from Varian®. The treatment planning system was the Eclipse® with its Inverse Planning Module Helios®. For verification a Portal Dosimetry system was used, a Photographic Dosimetry system with EDR2 Kodak® films, software RIT113® and Vidar Scanner, ionization chambers and two different phantoms. The generated procedures covered the whole activity from the initial verifications prior to the IMRT implementation, to the patients’ treatment and, in between, all the aspects related to the data acquisition, dose distribution calculation and quality assurance protocol. It was possible to achieve correct dose distributions with the application of the described procedures.Teixeira, NunoAlmeida, Pedro Miguel Dinis de, 1968-Repositório da Universidade de LisboaJoão, Iola Marisa Vicente Cardoso2012-02-23T12:22:25Z20092009-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10451/5379porinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-17T12:50:30Zoai:repositorio.ulisboa.pt:10451/5379Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T02:29:03.205376Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
title Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
spellingShingle Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
João, Iola Marisa Vicente Cardoso
IMRT
Implementação
Controlo de qualidade
Acelerador linear
Irradiação dinâmica
Teses de mestrado - 2009
title_short Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
title_full Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
title_fullStr Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
title_full_unstemmed Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
title_sort Implementação da técnica de IMRT no C.O.D.N.C.: procedimentos de implementação
author João, Iola Marisa Vicente Cardoso
author_facet João, Iola Marisa Vicente Cardoso
author_role author
dc.contributor.none.fl_str_mv Teixeira, Nuno
Almeida, Pedro Miguel Dinis de, 1968-
Repositório da Universidade de Lisboa
dc.contributor.author.fl_str_mv João, Iola Marisa Vicente Cardoso
dc.subject.por.fl_str_mv IMRT
Implementação
Controlo de qualidade
Acelerador linear
Irradiação dinâmica
Teses de mestrado - 2009
topic IMRT
Implementação
Controlo de qualidade
Acelerador linear
Irradiação dinâmica
Teses de mestrado - 2009
description Tese de mestrado, Biofísica (Física Médica e Engenharia Biomédica), Universidade de Lisboa, Faculdade de Ciências, 2009
publishDate 2009
dc.date.none.fl_str_mv 2009
2009-01-01T00:00:00Z
2012-02-23T12:22:25Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10451/5379
url http://hdl.handle.net/10451/5379
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833601376800735232