Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI
Main Author: | |
---|---|
Publication Date: | 2007 |
Other Authors: | , , , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/10316/4357 https://doi.org/10.1016/j.nima.2007.05.156 |
Summary: | Superheated droplet detectors (SDDs) have been investigated for applications in neutron dosimetry and spectrometry. Varying the detector temperature, it is possible to change the neutron energy detection threshold of SDDs, thus allowing the use of a single detector to measure neutrons of different energy, without any change of the experimental setup. However, the neutron threshold energy versus temperature curves have to be experimentally determined. The determination of the calibration curves requires the use of monochromatic neutron beams. |
id |
RCAP_f5e17cd98804640f67c3cc689c6bfdc4 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/4357 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPIQuasi-monochromatic neutron beamsSuperheated droplet detectorsSuperheated droplet detectors (SDDs) have been investigated for applications in neutron dosimetry and spectrometry. Varying the detector temperature, it is possible to change the neutron energy detection threshold of SDDs, thus allowing the use of a single detector to measure neutrons of different energy, without any change of the experimental setup. However, the neutron threshold energy versus temperature curves have to be experimentally determined. The determination of the calibration curves requires the use of monochromatic neutron beams.http://www.sciencedirect.com/science/article/B6TJM-4NS0KHR-M/1/5abd8420f5773d5838ee17598b0c57862007info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttps://hdl.handle.net/10316/4357https://hdl.handle.net/10316/4357https://doi.org/10.1016/j.nima.2007.05.156engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 580:1 (2007) 282-285Nascimento, F.Ramos, A. R.Fernandes, A. C.Felizardo, M.Morlat, T.Marques, J. G.Giuliani, F.Girard, T. A.Paixão, J. A.info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2020-11-06T16:49:20Zoai:estudogeral.uc.pt:10316/4357Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:21:47.658049Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
title |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
spellingShingle |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI Nascimento, F. Quasi-monochromatic neutron beams Superheated droplet detectors |
title_short |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
title_full |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
title_fullStr |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
title_full_unstemmed |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
title_sort |
Optimization of filtered neutron beams for the calibration of superheated droplet detectors at the RPI |
author |
Nascimento, F. |
author_facet |
Nascimento, F. Ramos, A. R. Fernandes, A. C. Felizardo, M. Morlat, T. Marques, J. G. Giuliani, F. Girard, T. A. Paixão, J. A. |
author_role |
author |
author2 |
Ramos, A. R. Fernandes, A. C. Felizardo, M. Morlat, T. Marques, J. G. Giuliani, F. Girard, T. A. Paixão, J. A. |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Nascimento, F. Ramos, A. R. Fernandes, A. C. Felizardo, M. Morlat, T. Marques, J. G. Giuliani, F. Girard, T. A. Paixão, J. A. |
dc.subject.por.fl_str_mv |
Quasi-monochromatic neutron beams Superheated droplet detectors |
topic |
Quasi-monochromatic neutron beams Superheated droplet detectors |
description |
Superheated droplet detectors (SDDs) have been investigated for applications in neutron dosimetry and spectrometry. Varying the detector temperature, it is possible to change the neutron energy detection threshold of SDDs, thus allowing the use of a single detector to measure neutrons of different energy, without any change of the experimental setup. However, the neutron threshold energy versus temperature curves have to be experimentally determined. The determination of the calibration curves requires the use of monochromatic neutron beams. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10316/4357 https://hdl.handle.net/10316/4357 https://doi.org/10.1016/j.nima.2007.05.156 |
url |
https://hdl.handle.net/10316/4357 https://doi.org/10.1016/j.nima.2007.05.156 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 580:1 (2007) 282-285 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833602330578124800 |