Export Ready — 

Glittre-Activities daily living test: physiological response in heart failure patients

Bibliographic Details
Main Author: Almeida, José Miguel Lopes Peixoto de
Publication Date: 2019
Format: Master thesis
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.22/13807
Summary: Background: Functional capacity and quality of life are measures of the heart failure (HF) patient’s health status and can demonstrate the impact of the disease on the ability to perform activities of daily living (ADL´s). The Glittre-ADL (TGlittre) test is supposed to evaluate patient´s functional capacity and their ability to perform activities of daily life. The physiological requirements of this test in HF patients are still unknown. Aim(s): Analyze and compare the cardiac, ventilatory and metabolic performance of the TGlittre, 6 minute walk test (6MWT) and cardiopulmonary exercise test (CPET) in patients with HF. Methods: A prospective cross-sectional study with 11 patients of both genders (median age of 65) with HF (median left ventricle ejection fraction of 40%) underwent anthropometric and lung function assessments and were submitted to a CPET. In separate day, with a maximum of 10 days apart, patients performed the TGlittre and 6MWT. Results: Baseline cardiopulmonary variables were similar between TGlittre and 6MWT (p>0,05). TGlittre induce significantly higher VE, VE/VO2, RER, HR and VE/MVV (p<0,05) compared to 6MWT. The other physiological variables were similar at the end of both tests. TGlittre showed a significant correlation with 6MWT distance (r=-0,64; p=0,04). In the final oxygen consumption (VO2), TGlittre showed a significant correlation with CPET (r=0,72; p=0,01) and 6MWT (r=0,67; p=0,02). TGlittre showed submaximal characteristics when compared with the CPET. Conclusion: TGlittre induce higher ventilatory and cardiovascular responses than the 6MWT, with similar metabolic adjustments.
id RCAP_f448b286d2246b4834a7adc3d90db4f5
oai_identifier_str oai:recipp.ipp.pt:10400.22/13807
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Glittre-Activities daily living test: physiological response in heart failure patientsheart failureTGlittreactivities of daily livingfunctional capacityBackground: Functional capacity and quality of life are measures of the heart failure (HF) patient’s health status and can demonstrate the impact of the disease on the ability to perform activities of daily living (ADL´s). The Glittre-ADL (TGlittre) test is supposed to evaluate patient´s functional capacity and their ability to perform activities of daily life. The physiological requirements of this test in HF patients are still unknown. Aim(s): Analyze and compare the cardiac, ventilatory and metabolic performance of the TGlittre, 6 minute walk test (6MWT) and cardiopulmonary exercise test (CPET) in patients with HF. Methods: A prospective cross-sectional study with 11 patients of both genders (median age of 65) with HF (median left ventricle ejection fraction of 40%) underwent anthropometric and lung function assessments and were submitted to a CPET. In separate day, with a maximum of 10 days apart, patients performed the TGlittre and 6MWT. Results: Baseline cardiopulmonary variables were similar between TGlittre and 6MWT (p>0,05). TGlittre induce significantly higher VE, VE/VO2, RER, HR and VE/MVV (p<0,05) compared to 6MWT. The other physiological variables were similar at the end of both tests. TGlittre showed a significant correlation with 6MWT distance (r=-0,64; p=0,04). In the final oxygen consumption (VO2), TGlittre showed a significant correlation with CPET (r=0,72; p=0,01) and 6MWT (r=0,67; p=0,02). TGlittre showed submaximal characteristics when compared with the CPET. Conclusion: TGlittre induce higher ventilatory and cardiovascular responses than the 6MWT, with similar metabolic adjustments.Santos, MárioSilva, Pedro MatosViamonte, SofiaREPOSITÓRIO P.PORTOAlmeida, José Miguel Lopes Peixoto de2019-05-29T12:11:24Z2019-032019-03-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.22/13807urn:tid:202249778enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-07T10:21:48Zoai:recipp.ipp.pt:10400.22/13807Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:50:17.800014Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Glittre-Activities daily living test: physiological response in heart failure patients
title Glittre-Activities daily living test: physiological response in heart failure patients
spellingShingle Glittre-Activities daily living test: physiological response in heart failure patients
Almeida, José Miguel Lopes Peixoto de
heart failure
TGlittre
activities of daily living
functional capacity
title_short Glittre-Activities daily living test: physiological response in heart failure patients
title_full Glittre-Activities daily living test: physiological response in heart failure patients
title_fullStr Glittre-Activities daily living test: physiological response in heart failure patients
title_full_unstemmed Glittre-Activities daily living test: physiological response in heart failure patients
title_sort Glittre-Activities daily living test: physiological response in heart failure patients
author Almeida, José Miguel Lopes Peixoto de
author_facet Almeida, José Miguel Lopes Peixoto de
author_role author
dc.contributor.none.fl_str_mv Santos, Mário
Silva, Pedro Matos
Viamonte, Sofia
REPOSITÓRIO P.PORTO
dc.contributor.author.fl_str_mv Almeida, José Miguel Lopes Peixoto de
dc.subject.por.fl_str_mv heart failure
TGlittre
activities of daily living
functional capacity
topic heart failure
TGlittre
activities of daily living
functional capacity
description Background: Functional capacity and quality of life are measures of the heart failure (HF) patient’s health status and can demonstrate the impact of the disease on the ability to perform activities of daily living (ADL´s). The Glittre-ADL (TGlittre) test is supposed to evaluate patient´s functional capacity and their ability to perform activities of daily life. The physiological requirements of this test in HF patients are still unknown. Aim(s): Analyze and compare the cardiac, ventilatory and metabolic performance of the TGlittre, 6 minute walk test (6MWT) and cardiopulmonary exercise test (CPET) in patients with HF. Methods: A prospective cross-sectional study with 11 patients of both genders (median age of 65) with HF (median left ventricle ejection fraction of 40%) underwent anthropometric and lung function assessments and were submitted to a CPET. In separate day, with a maximum of 10 days apart, patients performed the TGlittre and 6MWT. Results: Baseline cardiopulmonary variables were similar between TGlittre and 6MWT (p>0,05). TGlittre induce significantly higher VE, VE/VO2, RER, HR and VE/MVV (p<0,05) compared to 6MWT. The other physiological variables were similar at the end of both tests. TGlittre showed a significant correlation with 6MWT distance (r=-0,64; p=0,04). In the final oxygen consumption (VO2), TGlittre showed a significant correlation with CPET (r=0,72; p=0,01) and 6MWT (r=0,67; p=0,02). TGlittre showed submaximal characteristics when compared with the CPET. Conclusion: TGlittre induce higher ventilatory and cardiovascular responses than the 6MWT, with similar metabolic adjustments.
publishDate 2019
dc.date.none.fl_str_mv 2019-05-29T12:11:24Z
2019-03
2019-03-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/13807
urn:tid:202249778
url http://hdl.handle.net/10400.22/13807
identifier_str_mv urn:tid:202249778
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600719754625024