Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants

Bibliographic Details
Main Author: Bartolomeu, F.
Publication Date: 2019
Other Authors: Fonseca, J., Peixinho, N., Alves, N., Gasik, M., Silva, F.S., Miranda, G.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.8/8547
Summary: SLM accuracy for fabricating porous materials is a noteworthy hindrance when aiming to obtain biomaterial cellular structures owing precise geometry, porosity, open-cells dimension and mechanical properties as outcomes. This study provides a comprehensive characterization of seventeen biomaterial Ti6Al4V-based structures in which experimental and numerical investigations (compression stress-strain tests) were carried out. Monomaterial Ti6Al4V cellular structures and multi-material Ti6Al4V-PEEK cellular structures were designed, produced by SLM and characterized targeting orthopedic implants. In this work, the differences between the CAD design and the as-produced Ti6Al4V-based structures were obtained from image analysis and were used to develop predictive models. The results showed that dimensional deviations inherent to SLM fabrication are systematically found for different dimensional ranges. The present study proposes several mathematical models, having high coefficients of determination, that estimate the real dimensions, porosity and elastic modulus of Ti6Al4V-based cellular structures as function of the CAD model. Moreover, numerical analysis was performed to estimate the octahedral shear strain for correlating with bone mechanostat theory limits. The developed models can help engineers to design and obtain near-net shape SLM biomaterials matching the desired geometry, opencells dimensions, porosity and elastic modulus. The obtained results show that by using these AM structures design it is possible to fabricate components exhibiting a strain and elastic modulus that complies with that of bone, thus being suitable for orthopedic implants.
id RCAP_f05a0f426356860e91407c656f4ff7d8
oai_identifier_str oai:iconline.ipleiria.pt:10400.8/8547
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implantsSelective laser meltingTi6Al4VMulti-materialPredictive modelsElastic modulusSLM accuracy for fabricating porous materials is a noteworthy hindrance when aiming to obtain biomaterial cellular structures owing precise geometry, porosity, open-cells dimension and mechanical properties as outcomes. This study provides a comprehensive characterization of seventeen biomaterial Ti6Al4V-based structures in which experimental and numerical investigations (compression stress-strain tests) were carried out. Monomaterial Ti6Al4V cellular structures and multi-material Ti6Al4V-PEEK cellular structures were designed, produced by SLM and characterized targeting orthopedic implants. In this work, the differences between the CAD design and the as-produced Ti6Al4V-based structures were obtained from image analysis and were used to develop predictive models. The results showed that dimensional deviations inherent to SLM fabrication are systematically found for different dimensional ranges. The present study proposes several mathematical models, having high coefficients of determination, that estimate the real dimensions, porosity and elastic modulus of Ti6Al4V-based cellular structures as function of the CAD model. Moreover, numerical analysis was performed to estimate the octahedral shear strain for correlating with bone mechanostat theory limits. The developed models can help engineers to design and obtain near-net shape SLM biomaterials matching the desired geometry, opencells dimensions, porosity and elastic modulus. The obtained results show that by using these AM structures design it is possible to fabricate components exhibiting a strain and elastic modulus that complies with that of bone, thus being suitable for orthopedic implants.ElsevierRepositório IC-OnlineBartolomeu, F.Fonseca, J.Peixinho, N.Alves, N.Gasik, M.Silva, F.S.Miranda, G.2023-05-31T13:35:27Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.8/8547eng1751-6161https://doi.org/10.1016/j.jmbbm.2019.07.023info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-25T15:13:46Zoai:iconline.ipleiria.pt:10400.8/8547Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T20:52:56.952745Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
title Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
spellingShingle Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
Bartolomeu, F.
Selective laser melting
Ti6Al4V
Multi-material
Predictive models
Elastic modulus
title_short Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
title_full Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
title_fullStr Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
title_full_unstemmed Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
title_sort Predicting the output dimensions, porosity and elastic modulus of additive manufactured biomaterial structures targeting orthopedic implants
author Bartolomeu, F.
author_facet Bartolomeu, F.
Fonseca, J.
Peixinho, N.
Alves, N.
Gasik, M.
Silva, F.S.
Miranda, G.
author_role author
author2 Fonseca, J.
Peixinho, N.
Alves, N.
Gasik, M.
Silva, F.S.
Miranda, G.
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório IC-Online
dc.contributor.author.fl_str_mv Bartolomeu, F.
Fonseca, J.
Peixinho, N.
Alves, N.
Gasik, M.
Silva, F.S.
Miranda, G.
dc.subject.por.fl_str_mv Selective laser melting
Ti6Al4V
Multi-material
Predictive models
Elastic modulus
topic Selective laser melting
Ti6Al4V
Multi-material
Predictive models
Elastic modulus
description SLM accuracy for fabricating porous materials is a noteworthy hindrance when aiming to obtain biomaterial cellular structures owing precise geometry, porosity, open-cells dimension and mechanical properties as outcomes. This study provides a comprehensive characterization of seventeen biomaterial Ti6Al4V-based structures in which experimental and numerical investigations (compression stress-strain tests) were carried out. Monomaterial Ti6Al4V cellular structures and multi-material Ti6Al4V-PEEK cellular structures were designed, produced by SLM and characterized targeting orthopedic implants. In this work, the differences between the CAD design and the as-produced Ti6Al4V-based structures were obtained from image analysis and were used to develop predictive models. The results showed that dimensional deviations inherent to SLM fabrication are systematically found for different dimensional ranges. The present study proposes several mathematical models, having high coefficients of determination, that estimate the real dimensions, porosity and elastic modulus of Ti6Al4V-based cellular structures as function of the CAD model. Moreover, numerical analysis was performed to estimate the octahedral shear strain for correlating with bone mechanostat theory limits. The developed models can help engineers to design and obtain near-net shape SLM biomaterials matching the desired geometry, opencells dimensions, porosity and elastic modulus. The obtained results show that by using these AM structures design it is possible to fabricate components exhibiting a strain and elastic modulus that complies with that of bone, thus being suitable for orthopedic implants.
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01T00:00:00Z
2023-05-31T13:35:27Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.8/8547
url http://hdl.handle.net/10400.8/8547
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1751-6161
https://doi.org/10.1016/j.jmbbm.2019.07.023
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833598930895503360