Assessment of the durability performance of fiber-cement sheets
| Autor(a) principal: | |
|---|---|
| Data de Publicação: | 2013 |
| Outros Autores: | , |
| Tipo de documento: | Artigo |
| Idioma: | eng |
| Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Texto Completo: | http://hdl.handle.net/1822/24526 |
Resumo: | According to standards, the durability performance of fiber-cement sheets must be evaluated by comparing the modulus of rupture (MOR) before and after durability tests (freeze-thaw, soak-dry, and warm water) are completed. This paper investigated the MOR of two different fiber-cement sheets samples before and after durability tests as well as its ductility and toughness. Results showed no significant difference between the MOR of control specimens and that of the specimens submitted to durability tests except in the case of the freezing and thawing test where after 100 cycles, a 7–9% decrease was observed. The differences between the MOR of the control specimens and that of the specimens submitted to durability tests were negligible and acceptable in accordance to the requirements of the standard. However, toughness and ductility decreased considerably in specimens of sample 1 by 25, 35, and 15%, respectively, when exposed to soak-dry (25 and 50 cycles) and warm water conditions. In turn, the reduction in toughness and ductility for specimens of sample 2 exposed to soak-dry (50 cycles) and warm water conditions were of 40 and 7%, respectively. The results of this investigation suggest that ductility and toughness should also be considered to assess the durability performance of fiber-cement sheets. |
| id |
RCAP_eb7f53c0501624ec8afdbc19dfb651df |
|---|---|
| oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/24526 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Assessment of the durability performance of fiber-cement sheetsFiber-cement sheetsDurabilityFreeze-thawWarm waterSoak-dryScience & TechnologyAccording to standards, the durability performance of fiber-cement sheets must be evaluated by comparing the modulus of rupture (MOR) before and after durability tests (freeze-thaw, soak-dry, and warm water) are completed. This paper investigated the MOR of two different fiber-cement sheets samples before and after durability tests as well as its ductility and toughness. Results showed no significant difference between the MOR of control specimens and that of the specimens submitted to durability tests except in the case of the freezing and thawing test where after 100 cycles, a 7–9% decrease was observed. The differences between the MOR of the control specimens and that of the specimens submitted to durability tests were negligible and acceptable in accordance to the requirements of the standard. However, toughness and ductility decreased considerably in specimens of sample 1 by 25, 35, and 15%, respectively, when exposed to soak-dry (25 and 50 cycles) and warm water conditions. In turn, the reduction in toughness and ductility for specimens of sample 2 exposed to soak-dry (50 cycles) and warm water conditions were of 40 and 7%, respectively. The results of this investigation suggest that ductility and toughness should also be considered to assess the durability performance of fiber-cement sheets.American Society of Civil Engineers (ASCE)Universidade do MinhoJamshidi, M.Pakravan, H. R.Pacheco-Torgal, F.20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/24526eng0899-156110.1061/(ASCE)MT.1943-5533.0000637http://dx.doi.org/10.1061/(ASCE)MT.1943-5533.0000637info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T05:07:46Zoai:repositorium.sdum.uminho.pt:1822/24526Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:08:51.315270Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Assessment of the durability performance of fiber-cement sheets |
| title |
Assessment of the durability performance of fiber-cement sheets |
| spellingShingle |
Assessment of the durability performance of fiber-cement sheets Jamshidi, M. Fiber-cement sheets Durability Freeze-thaw Warm water Soak-dry Science & Technology |
| title_short |
Assessment of the durability performance of fiber-cement sheets |
| title_full |
Assessment of the durability performance of fiber-cement sheets |
| title_fullStr |
Assessment of the durability performance of fiber-cement sheets |
| title_full_unstemmed |
Assessment of the durability performance of fiber-cement sheets |
| title_sort |
Assessment of the durability performance of fiber-cement sheets |
| author |
Jamshidi, M. |
| author_facet |
Jamshidi, M. Pakravan, H. R. Pacheco-Torgal, F. |
| author_role |
author |
| author2 |
Pakravan, H. R. Pacheco-Torgal, F. |
| author2_role |
author author |
| dc.contributor.none.fl_str_mv |
Universidade do Minho |
| dc.contributor.author.fl_str_mv |
Jamshidi, M. Pakravan, H. R. Pacheco-Torgal, F. |
| dc.subject.por.fl_str_mv |
Fiber-cement sheets Durability Freeze-thaw Warm water Soak-dry Science & Technology |
| topic |
Fiber-cement sheets Durability Freeze-thaw Warm water Soak-dry Science & Technology |
| description |
According to standards, the durability performance of fiber-cement sheets must be evaluated by comparing the modulus of rupture (MOR) before and after durability tests (freeze-thaw, soak-dry, and warm water) are completed. This paper investigated the MOR of two different fiber-cement sheets samples before and after durability tests as well as its ductility and toughness. Results showed no significant difference between the MOR of control specimens and that of the specimens submitted to durability tests except in the case of the freezing and thawing test where after 100 cycles, a 7–9% decrease was observed. The differences between the MOR of the control specimens and that of the specimens submitted to durability tests were negligible and acceptable in accordance to the requirements of the standard. However, toughness and ductility decreased considerably in specimens of sample 1 by 25, 35, and 15%, respectively, when exposed to soak-dry (25 and 50 cycles) and warm water conditions. In turn, the reduction in toughness and ductility for specimens of sample 2 exposed to soak-dry (50 cycles) and warm water conditions were of 40 and 7%, respectively. The results of this investigation suggest that ductility and toughness should also be considered to assess the durability performance of fiber-cement sheets. |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013 2013-01-01T00:00:00Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/24526 |
| url |
http://hdl.handle.net/1822/24526 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
0899-1561 10.1061/(ASCE)MT.1943-5533.0000637 http://dx.doi.org/10.1061/(ASCE)MT.1943-5533.0000637 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
American Society of Civil Engineers (ASCE) |
| publisher.none.fl_str_mv |
American Society of Civil Engineers (ASCE) |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833595128322719744 |