Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests

Detalhes bibliográficos
Autor(a) principal: Costa, Inês
Data de Publicação: 2013
Outros Autores: Barros, Joaquim A. O.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://hdl.handle.net/1822/26269
Resumo: The study of the bond behaviour between fibre reinforced polymer (FRP) systems and concrete is an issue that nowadays attracts many researchers. The scientific community dedicated to the research of FRP reinforcement has been conducting numerous experimental programs aiming to assess the local bond-slip law of the FRP-adhesive-concrete connection. This paper reports the relevant results obtained by the Structural Composite Research Group of Minho University in the scope of an international Round Robin Test. The suitability of the recommended test setup to derive a local bond constitutive law for modelling the bond behaviour of Near Surface Mounted reinforcement systems is discussed based on a deep interpretation of the results. Keywords: Bond behaviour; Double-Shear pull-out test; Fibre reinforced
id RCAP_e792f6f7df973e4d52488206da49cb8c
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/26269
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out testsBond behaviourDouble-Shear pull-out testFibre reinforced polymer (FRP)Local bondslip lawNear Surface Mounted (NSM)Science & TechnologyThe study of the bond behaviour between fibre reinforced polymer (FRP) systems and concrete is an issue that nowadays attracts many researchers. The scientific community dedicated to the research of FRP reinforcement has been conducting numerous experimental programs aiming to assess the local bond-slip law of the FRP-adhesive-concrete connection. This paper reports the relevant results obtained by the Structural Composite Research Group of Minho University in the scope of an international Round Robin Test. The suitability of the recommended test setup to derive a local bond constitutive law for modelling the bond behaviour of Near Surface Mounted reinforcement systems is discussed based on a deep interpretation of the results. Keywords: Bond behaviour; Double-Shear pull-out test; Fibre reinforcedFundação para a Ciência e a Tecnologia (FCT)Wiley-BlackwellUniversidade do MinhoCosta, InêsBarros, Joaquim A. O.20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/26269eng1475-130510.1111/str.12038info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T05:05:15Zoai:repositorium.sdum.uminho.pt:1822/26269Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:07:30.116250Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
title Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
spellingShingle Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
Costa, Inês
Bond behaviour
Double-Shear pull-out test
Fibre reinforced polymer (FRP)
Local bondslip law
Near Surface Mounted (NSM)
Science & Technology
title_short Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
title_full Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
title_fullStr Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
title_full_unstemmed Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
title_sort Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
author Costa, Inês
author_facet Costa, Inês
Barros, Joaquim A. O.
author_role author
author2 Barros, Joaquim A. O.
author2_role author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Costa, Inês
Barros, Joaquim A. O.
dc.subject.por.fl_str_mv Bond behaviour
Double-Shear pull-out test
Fibre reinforced polymer (FRP)
Local bondslip law
Near Surface Mounted (NSM)
Science & Technology
topic Bond behaviour
Double-Shear pull-out test
Fibre reinforced polymer (FRP)
Local bondslip law
Near Surface Mounted (NSM)
Science & Technology
description The study of the bond behaviour between fibre reinforced polymer (FRP) systems and concrete is an issue that nowadays attracts many researchers. The scientific community dedicated to the research of FRP reinforcement has been conducting numerous experimental programs aiming to assess the local bond-slip law of the FRP-adhesive-concrete connection. This paper reports the relevant results obtained by the Structural Composite Research Group of Minho University in the scope of an international Round Robin Test. The suitability of the recommended test setup to derive a local bond constitutive law for modelling the bond behaviour of Near Surface Mounted reinforcement systems is discussed based on a deep interpretation of the results. Keywords: Bond behaviour; Double-Shear pull-out test; Fibre reinforced
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/26269
url http://hdl.handle.net/1822/26269
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1475-1305
10.1111/str.12038
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Wiley-Blackwell
publisher.none.fl_str_mv Wiley-Blackwell
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595114645094400