Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need?
| Main Author: | |
|---|---|
| Publication Date: | 2016 |
| Other Authors: | , , , |
| Format: | Article |
| Language: | eng |
| Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Download full: | http://hdl.handle.net/10400.16/2059 |
Summary: | INTRODUCTION: Comparatively to open repair, endovascular aneurysm repair has reduced transfusion rates but thereâs no recommendation about number of red blood cells units to be crossmatched preoperatively. Our aim is contribute to the analysis of red blood cells units needs in endovascular and hybrid aortic aneurysm repair and developing a protocol for maximum surgical blood orders schedule. MATERIAL AND METHODS: We retrospectively analyzed our prospective database of elective endovascular aneurysm repair from 2001 to 2012. We analyzed patients' age, gender, ASA classification, maximum surgical blood orders schedule, red blood cells units transfused and timings, types of endoprosthesis, red blood cells units consumption/endoprosthesis' type ratio, crossmatch to transfusion ratio, conversion to open repair, hemoglobin concentrations before surgery and discharge. RESULTS: We selected 187 patients, 90% men, mean age 73.1, ASA mode III. The endoprosthesis were aorto-bi-iliac in 71%, aorto-uni-iliac in 23% and thoracic in 6%. Of these, 72,6% of the patients did not require blood transfusion. We transfused 171 red blood cells units. Crossmatch to transfusion ratio was 10.1 until 2010 and 7.3 after. The ratio of red blood cells units consumption/endoprosthesis in the first 24 hours was 0.21 red blood cells units/aorto-bi-iliac, 0.46 red blood cells units/aorto-uni-iliac, 0.8 red blood cells units/thoracic, 1.3 red blood cells units/hybrid-thoracic and 2 red blood cells units/hybrid-aorto-bi-iliac. A statistical correlation was observed between red blood cells units transfused postoperatively and type of endoprosthesis (p < 0.001) and between ASA classification and red blood cells units transfused after 24 hours (p < 0.01). DISCUSSION: Guidelines from the British Society of Haematology are based on a crossmatch to transfusion ratio of 2:1. Our crossmatch to transfusion ratio was 10.1 until 2010 and 7.3 from 2011 to 2012. CONCLUSION: These results changed our policy of maximum surgical blood orders schedule for endovascular aneurysm repair. We now type and screen aorto-bi-iliac and aorto-uni-iliac. We crossmatch two red blood cells units for thoracic, three red blood cells units for hybrid thoracic and four red blood cells units for hybrid abdominal procedures. This may lead to financial savings, improved efficiency and reduce workload in hematology department. |
| id |
RCAP_e6b56fd47229fb23543a0706b2b298b8 |
|---|---|
| oai_identifier_str |
oai:repositorio.chporto.pt:10400.16/2059 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need?Tratamento Endovascular de Aneurismas da Aorta e Transfusão de Sangue. O que Precisamos?Aortic Aneurysm/surgeryBlood TransfusionClinical ProtocolsEndovascular ProceduresINTRODUCTION: Comparatively to open repair, endovascular aneurysm repair has reduced transfusion rates but thereâs no recommendation about number of red blood cells units to be crossmatched preoperatively. Our aim is contribute to the analysis of red blood cells units needs in endovascular and hybrid aortic aneurysm repair and developing a protocol for maximum surgical blood orders schedule. MATERIAL AND METHODS: We retrospectively analyzed our prospective database of elective endovascular aneurysm repair from 2001 to 2012. We analyzed patients' age, gender, ASA classification, maximum surgical blood orders schedule, red blood cells units transfused and timings, types of endoprosthesis, red blood cells units consumption/endoprosthesis' type ratio, crossmatch to transfusion ratio, conversion to open repair, hemoglobin concentrations before surgery and discharge. RESULTS: We selected 187 patients, 90% men, mean age 73.1, ASA mode III. The endoprosthesis were aorto-bi-iliac in 71%, aorto-uni-iliac in 23% and thoracic in 6%. Of these, 72,6% of the patients did not require blood transfusion. We transfused 171 red blood cells units. Crossmatch to transfusion ratio was 10.1 until 2010 and 7.3 after. The ratio of red blood cells units consumption/endoprosthesis in the first 24 hours was 0.21 red blood cells units/aorto-bi-iliac, 0.46 red blood cells units/aorto-uni-iliac, 0.8 red blood cells units/thoracic, 1.3 red blood cells units/hybrid-thoracic and 2 red blood cells units/hybrid-aorto-bi-iliac. A statistical correlation was observed between red blood cells units transfused postoperatively and type of endoprosthesis (p < 0.001) and between ASA classification and red blood cells units transfused after 24 hours (p < 0.01). DISCUSSION: Guidelines from the British Society of Haematology are based on a crossmatch to transfusion ratio of 2:1. Our crossmatch to transfusion ratio was 10.1 until 2010 and 7.3 from 2011 to 2012. CONCLUSION: These results changed our policy of maximum surgical blood orders schedule for endovascular aneurysm repair. We now type and screen aorto-bi-iliac and aorto-uni-iliac. We crossmatch two red blood cells units for thoracic, three red blood cells units for hybrid thoracic and four red blood cells units for hybrid abdominal procedures. This may lead to financial savings, improved efficiency and reduce workload in hematology department.Centro Livreiro da Ordem dos MédicosRepositório Científico da Unidade Local de Saúde de Santo AntónioMachado, R.Loureiro, L.Antunes, I.Coutinho, J.Almeida, R.2017-03-30T11:48:37Z2016-052016-05-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.16/2059eng0870-399X1646-075810.20344/amp.7283info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-26T10:09:23Zoai:repositorio.chporto.pt:10400.16/2059Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T21:20:58.059804Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? Tratamento Endovascular de Aneurismas da Aorta e Transfusão de Sangue. O que Precisamos? |
| title |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? |
| spellingShingle |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? Machado, R. Aortic Aneurysm/surgery Blood Transfusion Clinical Protocols Endovascular Procedures |
| title_short |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? |
| title_full |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? |
| title_fullStr |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? |
| title_full_unstemmed |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? |
| title_sort |
Endovascular Treatment of Aortic Aneurysms and Blood Transfusion. What do We Need? |
| author |
Machado, R. |
| author_facet |
Machado, R. Loureiro, L. Antunes, I. Coutinho, J. Almeida, R. |
| author_role |
author |
| author2 |
Loureiro, L. Antunes, I. Coutinho, J. Almeida, R. |
| author2_role |
author author author author |
| dc.contributor.none.fl_str_mv |
Repositório Científico da Unidade Local de Saúde de Santo António |
| dc.contributor.author.fl_str_mv |
Machado, R. Loureiro, L. Antunes, I. Coutinho, J. Almeida, R. |
| dc.subject.por.fl_str_mv |
Aortic Aneurysm/surgery Blood Transfusion Clinical Protocols Endovascular Procedures |
| topic |
Aortic Aneurysm/surgery Blood Transfusion Clinical Protocols Endovascular Procedures |
| description |
INTRODUCTION: Comparatively to open repair, endovascular aneurysm repair has reduced transfusion rates but thereâs no recommendation about number of red blood cells units to be crossmatched preoperatively. Our aim is contribute to the analysis of red blood cells units needs in endovascular and hybrid aortic aneurysm repair and developing a protocol for maximum surgical blood orders schedule. MATERIAL AND METHODS: We retrospectively analyzed our prospective database of elective endovascular aneurysm repair from 2001 to 2012. We analyzed patients' age, gender, ASA classification, maximum surgical blood orders schedule, red blood cells units transfused and timings, types of endoprosthesis, red blood cells units consumption/endoprosthesis' type ratio, crossmatch to transfusion ratio, conversion to open repair, hemoglobin concentrations before surgery and discharge. RESULTS: We selected 187 patients, 90% men, mean age 73.1, ASA mode III. The endoprosthesis were aorto-bi-iliac in 71%, aorto-uni-iliac in 23% and thoracic in 6%. Of these, 72,6% of the patients did not require blood transfusion. We transfused 171 red blood cells units. Crossmatch to transfusion ratio was 10.1 until 2010 and 7.3 after. The ratio of red blood cells units consumption/endoprosthesis in the first 24 hours was 0.21 red blood cells units/aorto-bi-iliac, 0.46 red blood cells units/aorto-uni-iliac, 0.8 red blood cells units/thoracic, 1.3 red blood cells units/hybrid-thoracic and 2 red blood cells units/hybrid-aorto-bi-iliac. A statistical correlation was observed between red blood cells units transfused postoperatively and type of endoprosthesis (p < 0.001) and between ASA classification and red blood cells units transfused after 24 hours (p < 0.01). DISCUSSION: Guidelines from the British Society of Haematology are based on a crossmatch to transfusion ratio of 2:1. Our crossmatch to transfusion ratio was 10.1 until 2010 and 7.3 from 2011 to 2012. CONCLUSION: These results changed our policy of maximum surgical blood orders schedule for endovascular aneurysm repair. We now type and screen aorto-bi-iliac and aorto-uni-iliac. We crossmatch two red blood cells units for thoracic, three red blood cells units for hybrid thoracic and four red blood cells units for hybrid abdominal procedures. This may lead to financial savings, improved efficiency and reduce workload in hematology department. |
| publishDate |
2016 |
| dc.date.none.fl_str_mv |
2016-05 2016-05-01T00:00:00Z 2017-03-30T11:48:37Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.16/2059 |
| url |
http://hdl.handle.net/10400.16/2059 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
0870-399X 1646-0758 10.20344/amp.7283 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Centro Livreiro da Ordem dos Médicos |
| publisher.none.fl_str_mv |
Centro Livreiro da Ordem dos Médicos |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833599236976934912 |