High temperature tests on partially encased beams
Main Author: | |
---|---|
Publication Date: | 2012 |
Other Authors: | , , |
Language: | por |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10198/11422 |
Summary: | Partially encased beams (PEB) are composite steel and concrete elements that present several advantages with respect to steel bare elements. This paper presents a set of experimental tests developed using two different beam lengths and two different shear conditions between stirrups and web (W – welded and NW – not welded), at high temperature (200, 400, 600 ºC) and room temperature. The composite section was built-up with IPE100 steel profile and reinforced concrete between flanges. The deformed shape mode and the bending resistance were compared for different temperature levels and stirrup shear conditions (W and NW). The behaviour of PEB was also compared with bare steel at room temperature. Most of the beams attained the ultimate limit state by lateral torsional buckling (LTB), with exception for those tested at 600 ºC, which collapsed by the formation of a plastic hinge (PH). |
id |
RCAP_e11d1d19492af28800acb405b69d91ae |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/11422 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
High temperature tests on partially encased beamsPartially encased beamsHigh temperatureExperimental testsBending resistancePartially encased beams (PEB) are composite steel and concrete elements that present several advantages with respect to steel bare elements. This paper presents a set of experimental tests developed using two different beam lengths and two different shear conditions between stirrups and web (W – welded and NW – not welded), at high temperature (200, 400, 600 ºC) and room temperature. The composite section was built-up with IPE100 steel profile and reinforced concrete between flanges. The deformed shape mode and the bending resistance were compared for different temperature levels and stirrup shear conditions (W and NW). The behaviour of PEB was also compared with bare steel at room temperature. Most of the beams attained the ultimate limit state by lateral torsional buckling (LTB), with exception for those tested at 600 ºC, which collapsed by the formation of a plastic hinge (PH).Biblioteca Digital do IPBPiloto, P.A.G.Ramos Gavilán, Ana BelénMesquita, L.M.R.Gonçalves, Carlos2014-12-15T11:20:11Z20122012-01-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10198/11422porPiloto, P.A.G.; Gavilán, Ana B. R.; Mesquita, L. M.R.; Gonçalves, Carlos (2012). High temperature tests on partially encased beams. In 7th International Conference on Structures in Fire. Zurich, Switzerland.10.3929/ethz-a-0070501097info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-25T12:02:22Zoai:bibliotecadigital.ipb.pt:10198/11422Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T11:27:32.173496Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
High temperature tests on partially encased beams |
title |
High temperature tests on partially encased beams |
spellingShingle |
High temperature tests on partially encased beams Piloto, P.A.G. Partially encased beams High temperature Experimental tests Bending resistance |
title_short |
High temperature tests on partially encased beams |
title_full |
High temperature tests on partially encased beams |
title_fullStr |
High temperature tests on partially encased beams |
title_full_unstemmed |
High temperature tests on partially encased beams |
title_sort |
High temperature tests on partially encased beams |
author |
Piloto, P.A.G. |
author_facet |
Piloto, P.A.G. Ramos Gavilán, Ana Belén Mesquita, L.M.R. Gonçalves, Carlos |
author_role |
author |
author2 |
Ramos Gavilán, Ana Belén Mesquita, L.M.R. Gonçalves, Carlos |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Piloto, P.A.G. Ramos Gavilán, Ana Belén Mesquita, L.M.R. Gonçalves, Carlos |
dc.subject.por.fl_str_mv |
Partially encased beams High temperature Experimental tests Bending resistance |
topic |
Partially encased beams High temperature Experimental tests Bending resistance |
description |
Partially encased beams (PEB) are composite steel and concrete elements that present several advantages with respect to steel bare elements. This paper presents a set of experimental tests developed using two different beam lengths and two different shear conditions between stirrups and web (W – welded and NW – not welded), at high temperature (200, 400, 600 ºC) and room temperature. The composite section was built-up with IPE100 steel profile and reinforced concrete between flanges. The deformed shape mode and the bending resistance were compared for different temperature levels and stirrup shear conditions (W and NW). The behaviour of PEB was also compared with bare steel at room temperature. Most of the beams attained the ultimate limit state by lateral torsional buckling (LTB), with exception for those tested at 600 ºC, which collapsed by the formation of a plastic hinge (PH). |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012 2012-01-01T00:00:00Z 2014-12-15T11:20:11Z |
dc.type.driver.fl_str_mv |
conference object |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/11422 |
url |
http://hdl.handle.net/10198/11422 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Piloto, P.A.G.; Gavilán, Ana B. R.; Mesquita, L. M.R.; Gonçalves, Carlos (2012). High temperature tests on partially encased beams. In 7th International Conference on Structures in Fire. Zurich, Switzerland. 10.3929/ethz-a-0070501097 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833591926022995968 |