Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD

Detalhes bibliográficos
Autor(a) principal: Marques, Alda
Data de Publicação: 2016
Outros Autores: Cruz, Joana, Quina, Sara, Regêncio, Maria, Jácome, Cristina
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://hdl.handle.net/10773/25100
Resumo: This study aimed to determine the interrater and intrarater reliability and agreement and the minimal detectable change (MDC) of the Timed Up & Go (TUG) test and the 10-Meter Walk Test (10MWT) in older patients with Chronic Obstructive Pulmonary Disease (COPD). Patients (≥ 60 years old) living in the community were asked to attend 2 sessions with 48-72-hour interval. In session 1, participants completed the TUG and 10MWT twice (2 trials) and were assessed by 2 raters. In session 2, they repeated the tests twice and were assessed by 1 rater. Interrater and intrarater reliability were calculated for the exact scores (using data from trial 1) and mean scores (mean of 2 trials) using Intraclass Correlation Coefficients (ICC2,1 and ICC2,2, respectively). Interrater and intrarater agreement were explored with the Bland & Altman method. The MDC95 was calculated from the standard error of measurement. Sixty participants (72.43 ± 6.90 years old) completed session 1 and 41 participants session 2. Excellent ICC values were found for the TUG test (interrater: ICC2,1 = 0.997 ICC2,2 = 0.999; intrarater: ICC2,1 = 0.921 ICC2,2 = 0.964) and 10MWT (interrater: ICC2,1 = 0.992 ICC2,2 = 0.997; intrarater: ICC2,1 = 0.903 ICC2,2 = 0.946). Good interrater and intrarater agreement was also found for both tests. The MDC95 was 2.68 s and 1.84 s for the TUG and 0.40 m/s and 0.30 m/s for the 10MWT considering the exact and mean scores, respectively. Findings suggest that the TUG test and the 10MWT are reliable and have acceptable measurement error. Therefore, these measures may be used to assess functional balance (TUG) and gait (10MWT) deficits in older patients with COPD.
id RCAP_dc861cce3455ff73b5d5fddcf579f2e6
oai_identifier_str oai:ria.ua.pt:10773/25100
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPDChronic lung diseaseFunctional balanceGait speedMeasurement propertiesWalkingThis study aimed to determine the interrater and intrarater reliability and agreement and the minimal detectable change (MDC) of the Timed Up & Go (TUG) test and the 10-Meter Walk Test (10MWT) in older patients with Chronic Obstructive Pulmonary Disease (COPD). Patients (≥ 60 years old) living in the community were asked to attend 2 sessions with 48-72-hour interval. In session 1, participants completed the TUG and 10MWT twice (2 trials) and were assessed by 2 raters. In session 2, they repeated the tests twice and were assessed by 1 rater. Interrater and intrarater reliability were calculated for the exact scores (using data from trial 1) and mean scores (mean of 2 trials) using Intraclass Correlation Coefficients (ICC2,1 and ICC2,2, respectively). Interrater and intrarater agreement were explored with the Bland & Altman method. The MDC95 was calculated from the standard error of measurement. Sixty participants (72.43 ± 6.90 years old) completed session 1 and 41 participants session 2. Excellent ICC values were found for the TUG test (interrater: ICC2,1 = 0.997 ICC2,2 = 0.999; intrarater: ICC2,1 = 0.921 ICC2,2 = 0.964) and 10MWT (interrater: ICC2,1 = 0.992 ICC2,2 = 0.997; intrarater: ICC2,1 = 0.903 ICC2,2 = 0.946). Good interrater and intrarater agreement was also found for both tests. The MDC95 was 2.68 s and 1.84 s for the TUG and 0.40 m/s and 0.30 m/s for the 10MWT considering the exact and mean scores, respectively. Findings suggest that the TUG test and the 10MWT are reliable and have acceptable measurement error. Therefore, these measures may be used to assess functional balance (TUG) and gait (10MWT) deficits in older patients with COPD.Taylor & Francis2019-01-14T15:03:41Z2016-05-03T00:00:00Z2016-05-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/25100eng1541-255510.3109/15412555.2015.1079816Marques, AldaCruz, JoanaQuina, SaraRegêncio, MariaJácome, Cristinainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-06T04:18:30Zoai:ria.ua.pt:10773/25100Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T14:04:02.451601Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
title Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
spellingShingle Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
Marques, Alda
Chronic lung disease
Functional balance
Gait speed
Measurement properties
Walking
title_short Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
title_full Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
title_fullStr Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
title_full_unstemmed Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
title_sort Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
author Marques, Alda
author_facet Marques, Alda
Cruz, Joana
Quina, Sara
Regêncio, Maria
Jácome, Cristina
author_role author
author2 Cruz, Joana
Quina, Sara
Regêncio, Maria
Jácome, Cristina
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Marques, Alda
Cruz, Joana
Quina, Sara
Regêncio, Maria
Jácome, Cristina
dc.subject.por.fl_str_mv Chronic lung disease
Functional balance
Gait speed
Measurement properties
Walking
topic Chronic lung disease
Functional balance
Gait speed
Measurement properties
Walking
description This study aimed to determine the interrater and intrarater reliability and agreement and the minimal detectable change (MDC) of the Timed Up & Go (TUG) test and the 10-Meter Walk Test (10MWT) in older patients with Chronic Obstructive Pulmonary Disease (COPD). Patients (≥ 60 years old) living in the community were asked to attend 2 sessions with 48-72-hour interval. In session 1, participants completed the TUG and 10MWT twice (2 trials) and were assessed by 2 raters. In session 2, they repeated the tests twice and were assessed by 1 rater. Interrater and intrarater reliability were calculated for the exact scores (using data from trial 1) and mean scores (mean of 2 trials) using Intraclass Correlation Coefficients (ICC2,1 and ICC2,2, respectively). Interrater and intrarater agreement were explored with the Bland & Altman method. The MDC95 was calculated from the standard error of measurement. Sixty participants (72.43 ± 6.90 years old) completed session 1 and 41 participants session 2. Excellent ICC values were found for the TUG test (interrater: ICC2,1 = 0.997 ICC2,2 = 0.999; intrarater: ICC2,1 = 0.921 ICC2,2 = 0.964) and 10MWT (interrater: ICC2,1 = 0.992 ICC2,2 = 0.997; intrarater: ICC2,1 = 0.903 ICC2,2 = 0.946). Good interrater and intrarater agreement was also found for both tests. The MDC95 was 2.68 s and 1.84 s for the TUG and 0.40 m/s and 0.30 m/s for the 10MWT considering the exact and mean scores, respectively. Findings suggest that the TUG test and the 10MWT are reliable and have acceptable measurement error. Therefore, these measures may be used to assess functional balance (TUG) and gait (10MWT) deficits in older patients with COPD.
publishDate 2016
dc.date.none.fl_str_mv 2016-05-03T00:00:00Z
2016-05-03
2019-01-14T15:03:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/25100
url http://hdl.handle.net/10773/25100
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1541-2555
10.3109/15412555.2015.1079816
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833594258683068416