Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos

Bibliographic Details
Main Author: Ferreira, Pedro Miguel Soares
Publication Date: 2015
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10773/14102
Summary: Os estudos de maquinabilidade de biomateriais e outros materiais aplicados na área médica são extensos. Todavia, muitos destes estudos recorrem a modelos de geometria regular e operações elementares de maquinagem. Relativamente a estas, os estudos académicos atualmente disponíveis mostram que a tecnologia preferencial é o torneamento, opção que se fundamenta na simplicidade de análise (corte ortogonal). Saliente-se ainda que, neste contexto, a liga de titânio Ti-6Al-4V constitui o biomaterial mais utilizado. Numa perspetiva complementar, refira-se que as publicações científicas evidenciam que a informação disponível sobre a fresagem Ti-6Al-4V não é muito extensa e a do Co-28Cr-6Mo é quase inexistente. A presente dissertação enquadra-se neste domínio e representa mais uma contribuição para o estudo da maquinabilidade das ligas de Titânio e de crómio-cobalto. A aplicação de operações de maquinagem complexas, através do recurso a programas informáticos de fabrico assistido por computador (CAM), em geometrias complexas, como é o caso das próteses femorais anatómicas, e o estudo comparativo da maquinabilidade das ligas Co-28Cr-6Mo e Ti-6Al-4V, constituem os objetivos fundamentais deste trabalho de doutoramento. Neste trabalho aborda-se a problemática da maquinabilidade das ligas metálicas usadas nos implantes ortopédicos, nomeadamente as ligas de titânio, de crómiocobalto e os aços Inoxidáveis. Efetua-se ainda um estudo da maquinagem de uma prótese femoral com uma forma geométrica complexa, onde as operações de corte foram geradas recorrendo às tecnologias de fabrico assistido por computador (CAD/CAM). Posteriormente, procedeu-se ao estudo da maquinabilidade das duas ligas usadas neste trabalho, dando uma atenção particular à determinação das forças de corte para diferentes velocidades de corte. Para além da monitorização da evolução da força de corte, o desgaste das ferramentas, a dureza e a rugosidade foram avaliadas, em função da velocidade de corte imposta. Por fim, com base nas estratégias de maquinagem adotadas, analisa-se a maquinabilidade e selecionam-se os parâmetros de corte mais favoráveis para as ligas de Titânio e Crómio-cobalto. Os resultados obtidos mostram que a liga de crómio-cobalto induz maior valor de força de corte do que a liga de titânio. Observa-se um aumento progressivo das forças de corte quando a velocidade de corte aumenta, até atingir o valor máximo para a velocidade de corte de 80m/min, após a qual, a força de corte tende a diminuir. Apesar do fabricante das ferramentas recomendar a velocidade de corte de 50 m/min para ambos os materiais, conclui-se que a velocidade de corte de 65 m/min induz o mesmo desgaste na ferramenta de corte no caso da liga de titânio, e menor desgaste no caso da liga de crómio-cobalto.
id RCAP_d4e739b2ee214736a0c3758400571a2e
oai_identifier_str oai:ria.ua.pt:10773/14102
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicosEngenharia mecânicaBiomecânicaPróteses - JoelhoBiomateriaisLigas de titânioLigas de crómioProcessos de fabricoOs estudos de maquinabilidade de biomateriais e outros materiais aplicados na área médica são extensos. Todavia, muitos destes estudos recorrem a modelos de geometria regular e operações elementares de maquinagem. Relativamente a estas, os estudos académicos atualmente disponíveis mostram que a tecnologia preferencial é o torneamento, opção que se fundamenta na simplicidade de análise (corte ortogonal). Saliente-se ainda que, neste contexto, a liga de titânio Ti-6Al-4V constitui o biomaterial mais utilizado. Numa perspetiva complementar, refira-se que as publicações científicas evidenciam que a informação disponível sobre a fresagem Ti-6Al-4V não é muito extensa e a do Co-28Cr-6Mo é quase inexistente. A presente dissertação enquadra-se neste domínio e representa mais uma contribuição para o estudo da maquinabilidade das ligas de Titânio e de crómio-cobalto. A aplicação de operações de maquinagem complexas, através do recurso a programas informáticos de fabrico assistido por computador (CAM), em geometrias complexas, como é o caso das próteses femorais anatómicas, e o estudo comparativo da maquinabilidade das ligas Co-28Cr-6Mo e Ti-6Al-4V, constituem os objetivos fundamentais deste trabalho de doutoramento. Neste trabalho aborda-se a problemática da maquinabilidade das ligas metálicas usadas nos implantes ortopédicos, nomeadamente as ligas de titânio, de crómiocobalto e os aços Inoxidáveis. Efetua-se ainda um estudo da maquinagem de uma prótese femoral com uma forma geométrica complexa, onde as operações de corte foram geradas recorrendo às tecnologias de fabrico assistido por computador (CAD/CAM). Posteriormente, procedeu-se ao estudo da maquinabilidade das duas ligas usadas neste trabalho, dando uma atenção particular à determinação das forças de corte para diferentes velocidades de corte. Para além da monitorização da evolução da força de corte, o desgaste das ferramentas, a dureza e a rugosidade foram avaliadas, em função da velocidade de corte imposta. Por fim, com base nas estratégias de maquinagem adotadas, analisa-se a maquinabilidade e selecionam-se os parâmetros de corte mais favoráveis para as ligas de Titânio e Crómio-cobalto. Os resultados obtidos mostram que a liga de crómio-cobalto induz maior valor de força de corte do que a liga de titânio. Observa-se um aumento progressivo das forças de corte quando a velocidade de corte aumenta, até atingir o valor máximo para a velocidade de corte de 80m/min, após a qual, a força de corte tende a diminuir. Apesar do fabricante das ferramentas recomendar a velocidade de corte de 50 m/min para ambos os materiais, conclui-se que a velocidade de corte de 65 m/min induz o mesmo desgaste na ferramenta de corte no caso da liga de titânio, e menor desgaste no caso da liga de crómio-cobalto.Studies regarding the machinability of biomaterials applied in the medical field are extensive. However, many of these studies are based on models with a regular geometry and using elementary machining operations. For these operations, the preferred technology used in academic studies is turning, due to the simplicity of analysis (orthogonal cutting). Moreover, the preferred biomaterial is the titanium alloy (Ti-6Al-4V). It should be also underlined that scientific studies published concerning the milling of Ti-6Al-4V are limited and for Co-28Cr-6Mo scarce. The present PhD Dissertation represents one more contribution to this field and aims to study the machinability of the titanium and chromium-cobalt alloys. The use of complex machining operations by means of software computer-aided manufacturing (CAM) in complex geometries such as the anatomical femoral prostheses and the study the machinability of the Co-28Cr- 6Mo and Ti-6Al -4V alloys represent the main objectives of the present work. In this study, the machining of a femoral prosthesis with a pre-defined complex geometric shape was developed, where the cutting operations were generated using the technology of computer-aided manufacturing (CAD/CAM) is performed. The study the machinability of the chromium-cobalt alloy (Co-28Cr- 6Mo) and titanium alloy (Ti-6Al-4V) is considered next. This work focuses in the determination of the cutting forces by selecting a given cutting speed and ensuring that the cross-sectional cut remains the same, as the cutting speed increases. Beyond the record of the progress of the cutting force, the tool´s abrasion, the hardness and the surface roughness were evaluated as a function of the cutting speed. Finally, based on machining strategies adopted, the most favorable cutting parameters are selected in order to carry out the machining with both alloys considered in this work. According to the results, the conclusions drawn from this thesis are the following: i) for chromium-cobalt alloy, a higher cutting force is obtained. The cutting force increases gradually, as cutting speed increases, till a maximum value at of 80 m/min, and then decreases ii) the tool manufacturer suggests a cutting speed of 50 m/min for both materials, but with a cutting speed of 65 m/min, same tool´s abrasion is obtained for the titanium alloy and less for chromium -cobalt alloy.Universidade de Aveiro2015-05-21T10:35:53Z2015-01-01T00:00:00Z2015doctoral thesisinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10773/14102TID:101417241porFerreira, Pedro Miguel Soaresinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-06T03:53:57Zoai:ria.ua.pt:10773/14102Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T13:50:11.110077Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
title Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
spellingShingle Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
Ferreira, Pedro Miguel Soares
Engenharia mecânica
Biomecânica
Próteses - Joelho
Biomateriais
Ligas de titânio
Ligas de crómio
Processos de fabrico
title_short Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
title_full Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
title_fullStr Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
title_full_unstemmed Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
title_sort Estudo da maquinabilidade das ligas Ti-6Al-4V e Co-28Cr-6Mo na fresagem de dispositivos biomédicos
author Ferreira, Pedro Miguel Soares
author_facet Ferreira, Pedro Miguel Soares
author_role author
dc.contributor.author.fl_str_mv Ferreira, Pedro Miguel Soares
dc.subject.por.fl_str_mv Engenharia mecânica
Biomecânica
Próteses - Joelho
Biomateriais
Ligas de titânio
Ligas de crómio
Processos de fabrico
topic Engenharia mecânica
Biomecânica
Próteses - Joelho
Biomateriais
Ligas de titânio
Ligas de crómio
Processos de fabrico
description Os estudos de maquinabilidade de biomateriais e outros materiais aplicados na área médica são extensos. Todavia, muitos destes estudos recorrem a modelos de geometria regular e operações elementares de maquinagem. Relativamente a estas, os estudos académicos atualmente disponíveis mostram que a tecnologia preferencial é o torneamento, opção que se fundamenta na simplicidade de análise (corte ortogonal). Saliente-se ainda que, neste contexto, a liga de titânio Ti-6Al-4V constitui o biomaterial mais utilizado. Numa perspetiva complementar, refira-se que as publicações científicas evidenciam que a informação disponível sobre a fresagem Ti-6Al-4V não é muito extensa e a do Co-28Cr-6Mo é quase inexistente. A presente dissertação enquadra-se neste domínio e representa mais uma contribuição para o estudo da maquinabilidade das ligas de Titânio e de crómio-cobalto. A aplicação de operações de maquinagem complexas, através do recurso a programas informáticos de fabrico assistido por computador (CAM), em geometrias complexas, como é o caso das próteses femorais anatómicas, e o estudo comparativo da maquinabilidade das ligas Co-28Cr-6Mo e Ti-6Al-4V, constituem os objetivos fundamentais deste trabalho de doutoramento. Neste trabalho aborda-se a problemática da maquinabilidade das ligas metálicas usadas nos implantes ortopédicos, nomeadamente as ligas de titânio, de crómiocobalto e os aços Inoxidáveis. Efetua-se ainda um estudo da maquinagem de uma prótese femoral com uma forma geométrica complexa, onde as operações de corte foram geradas recorrendo às tecnologias de fabrico assistido por computador (CAD/CAM). Posteriormente, procedeu-se ao estudo da maquinabilidade das duas ligas usadas neste trabalho, dando uma atenção particular à determinação das forças de corte para diferentes velocidades de corte. Para além da monitorização da evolução da força de corte, o desgaste das ferramentas, a dureza e a rugosidade foram avaliadas, em função da velocidade de corte imposta. Por fim, com base nas estratégias de maquinagem adotadas, analisa-se a maquinabilidade e selecionam-se os parâmetros de corte mais favoráveis para as ligas de Titânio e Crómio-cobalto. Os resultados obtidos mostram que a liga de crómio-cobalto induz maior valor de força de corte do que a liga de titânio. Observa-se um aumento progressivo das forças de corte quando a velocidade de corte aumenta, até atingir o valor máximo para a velocidade de corte de 80m/min, após a qual, a força de corte tende a diminuir. Apesar do fabricante das ferramentas recomendar a velocidade de corte de 50 m/min para ambos os materiais, conclui-se que a velocidade de corte de 65 m/min induz o mesmo desgaste na ferramenta de corte no caso da liga de titânio, e menor desgaste no caso da liga de crómio-cobalto.
publishDate 2015
dc.date.none.fl_str_mv 2015-05-21T10:35:53Z
2015-01-01T00:00:00Z
2015
dc.type.driver.fl_str_mv doctoral thesis
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/14102
TID:101417241
url http://hdl.handle.net/10773/14102
identifier_str_mv TID:101417241
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de Aveiro
publisher.none.fl_str_mv Universidade de Aveiro
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833594114903375872