Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids
Main Author: | |
---|---|
Publication Date: | 2009 |
Other Authors: | , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0870-83122009000200007 |
Summary: | The dental amalgam is a metallic alloy commonly utilized as a restorative material. In this study, Electrochemical Impedance Spectroscopy, polarisation curves and Mott-Schottky analysis were used to evaluate the physical characteristics of the passive film formed on amalgam surface; X-Ray and UV spectrophotometric analyses were also used to determine the alloy phases and possible soluble corrosion products, respectively. This study was done with Duxalloy® and Tytin® Plus samples in four different electrolytes: Phosphate Buffer Saline, Hank Solution, Artificial Saliva and NaCl 0.9%. In general, the longer the immersion time, the smaller the resistance, possibly due to film breakage; Duxalloy® presented, at the end of 168 h of immersion, a higher resistance when compared to Tytin® Plus. X-Ray analysis showed differences between the two studied brands. UV spectrophotometric analysis demonstrated a small absorption band at ~276 nm. These films kept their protective properties after 168 h of immersion |
id |
RCAP_d0ba25cdb7650d4cc42e8a5fce78e3a9 |
---|---|
oai_identifier_str |
oai:scielo:S0870-83122009000200007 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluidsDental amalgamsElectrochemical Impedance SpectroscopyCorrosion, Mott-SchottkyPolarisation CurvesThe dental amalgam is a metallic alloy commonly utilized as a restorative material. In this study, Electrochemical Impedance Spectroscopy, polarisation curves and Mott-Schottky analysis were used to evaluate the physical characteristics of the passive film formed on amalgam surface; X-Ray and UV spectrophotometric analyses were also used to determine the alloy phases and possible soluble corrosion products, respectively. This study was done with Duxalloy® and Tytin® Plus samples in four different electrolytes: Phosphate Buffer Saline, Hank Solution, Artificial Saliva and NaCl 0.9%. In general, the longer the immersion time, the smaller the resistance, possibly due to film breakage; Duxalloy® presented, at the end of 168 h of immersion, a higher resistance when compared to Tytin® Plus. X-Ray analysis showed differences between the two studied brands. UV spectrophotometric analysis demonstrated a small absorption band at ~276 nm. These films kept their protective properties after 168 h of immersionSociedade Portuguesa de Materiais2009-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0870-83122009000200007Ciência & Tecnologia dos Materiais v.21 n.3-4 2009reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0870-83122009000200007Alves,V. A.Souza,D. G.Reis,R. Q.Silva,L. A. daRossi,A.info:eu-repo/semantics/openAccess2024-02-06T17:01:07Zoai:scielo:S0870-83122009000200007Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:51:06.553942Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
title |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
spellingShingle |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids Alves,V. A. Dental amalgams Electrochemical Impedance Spectroscopy Corrosion, Mott-Schottky Polarisation Curves |
title_short |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
title_full |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
title_fullStr |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
title_full_unstemmed |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
title_sort |
Electrochemical impedance applied to the corrosion behavior of dental amalgams in synthetic physiological fluids |
author |
Alves,V. A. |
author_facet |
Alves,V. A. Souza,D. G. Reis,R. Q. Silva,L. A. da Rossi,A. |
author_role |
author |
author2 |
Souza,D. G. Reis,R. Q. Silva,L. A. da Rossi,A. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Alves,V. A. Souza,D. G. Reis,R. Q. Silva,L. A. da Rossi,A. |
dc.subject.por.fl_str_mv |
Dental amalgams Electrochemical Impedance Spectroscopy Corrosion, Mott-Schottky Polarisation Curves |
topic |
Dental amalgams Electrochemical Impedance Spectroscopy Corrosion, Mott-Schottky Polarisation Curves |
description |
The dental amalgam is a metallic alloy commonly utilized as a restorative material. In this study, Electrochemical Impedance Spectroscopy, polarisation curves and Mott-Schottky analysis were used to evaluate the physical characteristics of the passive film formed on amalgam surface; X-Ray and UV spectrophotometric analyses were also used to determine the alloy phases and possible soluble corrosion products, respectively. This study was done with Duxalloy® and Tytin® Plus samples in four different electrolytes: Phosphate Buffer Saline, Hank Solution, Artificial Saliva and NaCl 0.9%. In general, the longer the immersion time, the smaller the resistance, possibly due to film breakage; Duxalloy® presented, at the end of 168 h of immersion, a higher resistance when compared to Tytin® Plus. X-Ray analysis showed differences between the two studied brands. UV spectrophotometric analysis demonstrated a small absorption band at ~276 nm. These films kept their protective properties after 168 h of immersion |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-07-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0870-83122009000200007 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0870-83122009000200007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0870-83122009000200007 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Materiais |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Materiais |
dc.source.none.fl_str_mv |
Ciência & Tecnologia dos Materiais v.21 n.3-4 2009 reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833593179443560448 |