Optimization of a pressurization methodology for extracting pore-water

Bibliographic Details
Main Author: Lopes, Isabel
Publication Date: 2005
Other Authors: Ribeiro, Rui
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10316/5360
https://doi.org/10.1016/j.chemosphere.2005.04.041
Summary: Sediment toxicity can be assessed by conducting pore-water toxicity assays with standard water column organisms. Several methods have been developed for sampling pore-water. Centrifugation and pressurization methods are recommended when large volumes of pore-water are required to perform toxicity assays. Nevertheless, these methods involve sediment transportation and storage in laboratory, which can alter sediment toxicity. Therefore, an extraction method for large volumes that could be employed in the field site would be highly desirable. This study aimed to optimize and further evaluate an existing sediment pressurizing device with low construction costs, easy to carry and operate in the field, and presenting minimal chemical reactivity. The latter characteristic was achieved by lining the device interior with Teflon, by using large pore filters (50 [mu]m), and by using an inert gas (nitrogen). Pore-water extraction efficiency and the toxicities of pore-water samples obtained by pressurization and by refrigerated centrifugation were compared. An artificial sediment (70% sand, 20% kaolin and 10% alpha-cellulose) spiked with an alcohol (phenol), a surfactant (SDS), a metal (copper), an organophosphate pesticide (parathion), and a natural sediment contaminated with acid mine drainage, were assayed for toxicity using Microtox assays. Sediment pressurization was found to be as efficient to extract pore-water as centrifugation, being more cost effective and adequate for field use.
id RCAP_ccac7b7632c683a4d4850e96e2014e95
oai_identifier_str oai:estudogeral.uc.pt:10316/5360
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Optimization of a pressurization methodology for extracting pore-waterSqueezing deviceCentrifugationInterstitial waterSedimentToxicityMicrotoxSediment toxicity can be assessed by conducting pore-water toxicity assays with standard water column organisms. Several methods have been developed for sampling pore-water. Centrifugation and pressurization methods are recommended when large volumes of pore-water are required to perform toxicity assays. Nevertheless, these methods involve sediment transportation and storage in laboratory, which can alter sediment toxicity. Therefore, an extraction method for large volumes that could be employed in the field site would be highly desirable. This study aimed to optimize and further evaluate an existing sediment pressurizing device with low construction costs, easy to carry and operate in the field, and presenting minimal chemical reactivity. The latter characteristic was achieved by lining the device interior with Teflon, by using large pore filters (50 [mu]m), and by using an inert gas (nitrogen). Pore-water extraction efficiency and the toxicities of pore-water samples obtained by pressurization and by refrigerated centrifugation were compared. An artificial sediment (70% sand, 20% kaolin and 10% alpha-cellulose) spiked with an alcohol (phenol), a surfactant (SDS), a metal (copper), an organophosphate pesticide (parathion), and a natural sediment contaminated with acid mine drainage, were assayed for toxicity using Microtox assays. Sediment pressurization was found to be as efficient to extract pore-water as centrifugation, being more cost effective and adequate for field use.http://www.sciencedirect.com/science/article/B6V74-4GFCPNM-2/1/cbb0172a719e5520424402dba7d440782005info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttps://hdl.handle.net/10316/5360https://hdl.handle.net/10316/5360https://doi.org/10.1016/j.chemosphere.2005.04.041engChemosphere. 61:10 (2005) 1505-1511Lopes, IsabelRibeiro, Ruiinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2021-09-20T11:01:31Zoai:estudogeral.uc.pt:10316/5360Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:14:25.812612Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Optimization of a pressurization methodology for extracting pore-water
title Optimization of a pressurization methodology for extracting pore-water
spellingShingle Optimization of a pressurization methodology for extracting pore-water
Lopes, Isabel
Squeezing device
Centrifugation
Interstitial water
Sediment
Toxicity
Microtox
title_short Optimization of a pressurization methodology for extracting pore-water
title_full Optimization of a pressurization methodology for extracting pore-water
title_fullStr Optimization of a pressurization methodology for extracting pore-water
title_full_unstemmed Optimization of a pressurization methodology for extracting pore-water
title_sort Optimization of a pressurization methodology for extracting pore-water
author Lopes, Isabel
author_facet Lopes, Isabel
Ribeiro, Rui
author_role author
author2 Ribeiro, Rui
author2_role author
dc.contributor.author.fl_str_mv Lopes, Isabel
Ribeiro, Rui
dc.subject.por.fl_str_mv Squeezing device
Centrifugation
Interstitial water
Sediment
Toxicity
Microtox
topic Squeezing device
Centrifugation
Interstitial water
Sediment
Toxicity
Microtox
description Sediment toxicity can be assessed by conducting pore-water toxicity assays with standard water column organisms. Several methods have been developed for sampling pore-water. Centrifugation and pressurization methods are recommended when large volumes of pore-water are required to perform toxicity assays. Nevertheless, these methods involve sediment transportation and storage in laboratory, which can alter sediment toxicity. Therefore, an extraction method for large volumes that could be employed in the field site would be highly desirable. This study aimed to optimize and further evaluate an existing sediment pressurizing device with low construction costs, easy to carry and operate in the field, and presenting minimal chemical reactivity. The latter characteristic was achieved by lining the device interior with Teflon, by using large pore filters (50 [mu]m), and by using an inert gas (nitrogen). Pore-water extraction efficiency and the toxicities of pore-water samples obtained by pressurization and by refrigerated centrifugation were compared. An artificial sediment (70% sand, 20% kaolin and 10% alpha-cellulose) spiked with an alcohol (phenol), a surfactant (SDS), a metal (copper), an organophosphate pesticide (parathion), and a natural sediment contaminated with acid mine drainage, were assayed for toxicity using Microtox assays. Sediment pressurization was found to be as efficient to extract pore-water as centrifugation, being more cost effective and adequate for field use.
publishDate 2005
dc.date.none.fl_str_mv 2005
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10316/5360
https://hdl.handle.net/10316/5360
https://doi.org/10.1016/j.chemosphere.2005.04.041
url https://hdl.handle.net/10316/5360
https://doi.org/10.1016/j.chemosphere.2005.04.041
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Chemosphere. 61:10 (2005) 1505-1511
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602293947170816