Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra

Detalhes bibliográficos
Autor(a) principal: Vicente, R.
Data de Publicação: 2006
Outros Autores: Rodrigues, H., Varum, H.
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://hdl.handle.net/10773/8131
Resumo: The increasing concern and consequent appraisal on durability, conservation state and changeable use and function of old buildings in urban centres relies a great deal on the structural safety evaluation of vertical load capacity but also the capable resistance to horizontal forces. The need to assess seismic vulnerability, particularly of the traditional masonry buildings is a key issue. Particular attention has been put upon the building stock of the old city centre of Coimbra, mainly constituted by old masonry load-bearing buildings of significant architectural value. The evaluation of the seismic vulnerability of old buildings is essential in the definition of the strengthening needs and minimization of possible damages due to seismic actions, in safeguarding of built heritage or in the identification of critical buildings. This paper intends to contribute for the assessment of old buildings considering the local seismic risk. A three dimensional model was developed for an aggregate of four buildings. The finite element modelling of these buildings has intended to identify structural fragilities, help understand the damages detected in the existing structures (crack opening) and evaluate the global structural safety of this type of buildings. It will be presented the main results obtained in this study, interpreted the structural damage, stress distribution and verified the global stability and its consequences. The dynamic response of such constructions to seismic actions has allowed studying the structural vulnerability. Different strengthening techniques to improve the global behaviour of these buildings were modelled and analysed. Efficiency comparison of the strengthening strategies is also discussed.
id RCAP_c9777f7b80bb9f501584ab6f93585a80
oai_identifier_str oai:ria.ua.pt:10773/8131
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Seismic performance and strengthening of traditional masonry buildings in the city centre of CoimbraOld city centresExisting masonryFinite element modellingStructural evaluationDamageSeismic vulnerabilityDynamic behaviourStrengthening techniquesThe increasing concern and consequent appraisal on durability, conservation state and changeable use and function of old buildings in urban centres relies a great deal on the structural safety evaluation of vertical load capacity but also the capable resistance to horizontal forces. The need to assess seismic vulnerability, particularly of the traditional masonry buildings is a key issue. Particular attention has been put upon the building stock of the old city centre of Coimbra, mainly constituted by old masonry load-bearing buildings of significant architectural value. The evaluation of the seismic vulnerability of old buildings is essential in the definition of the strengthening needs and minimization of possible damages due to seismic actions, in safeguarding of built heritage or in the identification of critical buildings. This paper intends to contribute for the assessment of old buildings considering the local seismic risk. A three dimensional model was developed for an aggregate of four buildings. The finite element modelling of these buildings has intended to identify structural fragilities, help understand the damages detected in the existing structures (crack opening) and evaluate the global structural safety of this type of buildings. It will be presented the main results obtained in this study, interpreted the structural damage, stress distribution and verified the global stability and its consequences. The dynamic response of such constructions to seismic actions has allowed studying the structural vulnerability. Different strengthening techniques to improve the global behaviour of these buildings were modelled and analysed. Efficiency comparison of the strengthening strategies is also discussed.2012-04-16T15:53:53Z2006-01-01T00:00:00Z2006conference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10773/8131engVicente, R.Rodrigues, H.Varum, H.info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-06T03:39:01Zoai:ria.ua.pt:10773/8131Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T13:41:45.749562Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
title Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
spellingShingle Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
Vicente, R.
Old city centres
Existing masonry
Finite element modelling
Structural evaluation
Damage
Seismic vulnerability
Dynamic behaviour
Strengthening techniques
title_short Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
title_full Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
title_fullStr Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
title_full_unstemmed Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
title_sort Seismic performance and strengthening of traditional masonry buildings in the city centre of Coimbra
author Vicente, R.
author_facet Vicente, R.
Rodrigues, H.
Varum, H.
author_role author
author2 Rodrigues, H.
Varum, H.
author2_role author
author
dc.contributor.author.fl_str_mv Vicente, R.
Rodrigues, H.
Varum, H.
dc.subject.por.fl_str_mv Old city centres
Existing masonry
Finite element modelling
Structural evaluation
Damage
Seismic vulnerability
Dynamic behaviour
Strengthening techniques
topic Old city centres
Existing masonry
Finite element modelling
Structural evaluation
Damage
Seismic vulnerability
Dynamic behaviour
Strengthening techniques
description The increasing concern and consequent appraisal on durability, conservation state and changeable use and function of old buildings in urban centres relies a great deal on the structural safety evaluation of vertical load capacity but also the capable resistance to horizontal forces. The need to assess seismic vulnerability, particularly of the traditional masonry buildings is a key issue. Particular attention has been put upon the building stock of the old city centre of Coimbra, mainly constituted by old masonry load-bearing buildings of significant architectural value. The evaluation of the seismic vulnerability of old buildings is essential in the definition of the strengthening needs and minimization of possible damages due to seismic actions, in safeguarding of built heritage or in the identification of critical buildings. This paper intends to contribute for the assessment of old buildings considering the local seismic risk. A three dimensional model was developed for an aggregate of four buildings. The finite element modelling of these buildings has intended to identify structural fragilities, help understand the damages detected in the existing structures (crack opening) and evaluate the global structural safety of this type of buildings. It will be presented the main results obtained in this study, interpreted the structural damage, stress distribution and verified the global stability and its consequences. The dynamic response of such constructions to seismic actions has allowed studying the structural vulnerability. Different strengthening techniques to improve the global behaviour of these buildings were modelled and analysed. Efficiency comparison of the strengthening strategies is also discussed.
publishDate 2006
dc.date.none.fl_str_mv 2006-01-01T00:00:00Z
2006
2012-04-16T15:53:53Z
dc.type.driver.fl_str_mv conference object
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/8131
url http://hdl.handle.net/10773/8131
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833593989861736448