Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays
Main Author: | |
---|---|
Publication Date: | 2016 |
Other Authors: | , , , , , , , , , , , , , , , , , , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.1/9216 |
Summary: | Background: There is scant information on the accuracy of different assays used to measure anti-infliximab antibodies (ADAs), especially in the presence of detectable infliximab (IFX). We thus aimed to evaluate and compare three different assays for the detection of IFX and ADAs and to clarify the impact of the presence of circulating IFX on the accuracy of the ADA assays.Methods: Blood samples from 79 ulcerative colitis (UC) patients treated with infliximab were assessed for IFX levels and ADAs using three different assays: an in-house assay and two commercial kits, Immundiagnostik and Theradiag. Sera samples with ADAs and undetectable levels of IFX were spiked with exogenous IFX and analyzed for ADAs.Results: The three assays showed 81-96% agreement for the measured IFX level. However, the in-house assay and Immundiagnostik assays detected ADAs in 34 out of 79 samples, whereas Theradiag only detected ADAs in 24 samples. Samples negative for ADAs with Theradiag, but ADA-positive in both the in-house and Immundiagnostik assays, were positive for IFX or IgG4 ADAs. In spiking experiments, a low concentration of exogenous IFX (5 mu g/ml) hampered ADA detection with Theradiag in sera samples with ADA levels of between 3 and 10 mu g/ml. In the Immundiagnostik assay detection interference was only observed at concentrations of exogenous IFX higher than 30 mu g/ml. However, in samples with high levels of ADAs (> 25 mu g/ml) interference was only observed at IFX concentrations higher than 100 mu g/ml in all three assays. Binary (IFX/ADA) stratification of the results showed that IFX+/ADA and IFX-/ADAs + were less influenced by the assay results than the double-positive (IFX+/ADAs+) and double-negative (IFX-/ADAs-) combination.Conclusions: All three methodologies are equally suitable for measuring IFX levels. However, erroneous therapeutic decisions may occur when patients show double-negative (IFX-/ADAs) or double-positive (IFX+/ADAs+) status, since agreement between assays is significantly lower in these circumstances. |
id |
RCAP_c96cae13161cdf82b29d002ce36a6fb3 |
---|---|
oai_identifier_str |
oai:sapientia.ualg.pt:10400.1/9216 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assaysAnti-infliximab antibodiesAnti-Infliximab antibody methodologiesInfliximab trough levelsTherapeutic drug monitoringBackground: There is scant information on the accuracy of different assays used to measure anti-infliximab antibodies (ADAs), especially in the presence of detectable infliximab (IFX). We thus aimed to evaluate and compare three different assays for the detection of IFX and ADAs and to clarify the impact of the presence of circulating IFX on the accuracy of the ADA assays.Methods: Blood samples from 79 ulcerative colitis (UC) patients treated with infliximab were assessed for IFX levels and ADAs using three different assays: an in-house assay and two commercial kits, Immundiagnostik and Theradiag. Sera samples with ADAs and undetectable levels of IFX were spiked with exogenous IFX and analyzed for ADAs.Results: The three assays showed 81-96% agreement for the measured IFX level. However, the in-house assay and Immundiagnostik assays detected ADAs in 34 out of 79 samples, whereas Theradiag only detected ADAs in 24 samples. Samples negative for ADAs with Theradiag, but ADA-positive in both the in-house and Immundiagnostik assays, were positive for IFX or IgG4 ADAs. In spiking experiments, a low concentration of exogenous IFX (5 mu g/ml) hampered ADA detection with Theradiag in sera samples with ADA levels of between 3 and 10 mu g/ml. In the Immundiagnostik assay detection interference was only observed at concentrations of exogenous IFX higher than 30 mu g/ml. However, in samples with high levels of ADAs (> 25 mu g/ml) interference was only observed at IFX concentrations higher than 100 mu g/ml in all three assays. Binary (IFX/ADA) stratification of the results showed that IFX+/ADA and IFX-/ADAs + were less influenced by the assay results than the double-positive (IFX+/ADAs+) and double-negative (IFX-/ADAs-) combination.Conclusions: All three methodologies are equally suitable for measuring IFX levels. However, erroneous therapeutic decisions may occur when patients show double-negative (IFX-/ADAs) or double-positive (IFX+/ADAs+) status, since agreement between assays is significantly lower in these circumstances.SAGE PublicationsSapientiaAfonso, JoanaLopes, SusanaGonçalves, RaquelCaldeira, PauloLago, PaulaSousa, Helena TavaresRamos, JaimeGonçalves, Ana RitaMinistro, PaulaRosa, IsadoraVieira, Ana IsabelCoelho, RosaTavares, PatríciaSoares, JoãoSousa, Ana LúciaCarvalho, DianaSousa, PaulaSilva, João Pereira daMeira, TâniaFerreira, Filipa SilvaDias, Cláudia CamilaChowers, YehudaBen-Horin, ShomronMagro, Fernando2017-04-07T15:55:46Z2016-072016-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.1/9216eng1756-283X10.1177/1756283X16658223info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-18T17:46:17Zoai:sapientia.ualg.pt:10400.1/9216Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T20:35:20.262618Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
title |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
spellingShingle |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays Afonso, Joana Anti-infliximab antibodies Anti-Infliximab antibody methodologies Infliximab trough levels Therapeutic drug monitoring |
title_short |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
title_full |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
title_fullStr |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
title_full_unstemmed |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
title_sort |
Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays |
author |
Afonso, Joana |
author_facet |
Afonso, Joana Lopes, Susana Gonçalves, Raquel Caldeira, Paulo Lago, Paula Sousa, Helena Tavares Ramos, Jaime Gonçalves, Ana Rita Ministro, Paula Rosa, Isadora Vieira, Ana Isabel Coelho, Rosa Tavares, Patrícia Soares, João Sousa, Ana Lúcia Carvalho, Diana Sousa, Paula Silva, João Pereira da Meira, Tânia Ferreira, Filipa Silva Dias, Cláudia Camila Chowers, Yehuda Ben-Horin, Shomron Magro, Fernando |
author_role |
author |
author2 |
Lopes, Susana Gonçalves, Raquel Caldeira, Paulo Lago, Paula Sousa, Helena Tavares Ramos, Jaime Gonçalves, Ana Rita Ministro, Paula Rosa, Isadora Vieira, Ana Isabel Coelho, Rosa Tavares, Patrícia Soares, João Sousa, Ana Lúcia Carvalho, Diana Sousa, Paula Silva, João Pereira da Meira, Tânia Ferreira, Filipa Silva Dias, Cláudia Camila Chowers, Yehuda Ben-Horin, Shomron Magro, Fernando |
author2_role |
author author author author author author author author author author author author author author author author author author author author author author author |
dc.contributor.none.fl_str_mv |
Sapientia |
dc.contributor.author.fl_str_mv |
Afonso, Joana Lopes, Susana Gonçalves, Raquel Caldeira, Paulo Lago, Paula Sousa, Helena Tavares Ramos, Jaime Gonçalves, Ana Rita Ministro, Paula Rosa, Isadora Vieira, Ana Isabel Coelho, Rosa Tavares, Patrícia Soares, João Sousa, Ana Lúcia Carvalho, Diana Sousa, Paula Silva, João Pereira da Meira, Tânia Ferreira, Filipa Silva Dias, Cláudia Camila Chowers, Yehuda Ben-Horin, Shomron Magro, Fernando |
dc.subject.por.fl_str_mv |
Anti-infliximab antibodies Anti-Infliximab antibody methodologies Infliximab trough levels Therapeutic drug monitoring |
topic |
Anti-infliximab antibodies Anti-Infliximab antibody methodologies Infliximab trough levels Therapeutic drug monitoring |
description |
Background: There is scant information on the accuracy of different assays used to measure anti-infliximab antibodies (ADAs), especially in the presence of detectable infliximab (IFX). We thus aimed to evaluate and compare three different assays for the detection of IFX and ADAs and to clarify the impact of the presence of circulating IFX on the accuracy of the ADA assays.Methods: Blood samples from 79 ulcerative colitis (UC) patients treated with infliximab were assessed for IFX levels and ADAs using three different assays: an in-house assay and two commercial kits, Immundiagnostik and Theradiag. Sera samples with ADAs and undetectable levels of IFX were spiked with exogenous IFX and analyzed for ADAs.Results: The three assays showed 81-96% agreement for the measured IFX level. However, the in-house assay and Immundiagnostik assays detected ADAs in 34 out of 79 samples, whereas Theradiag only detected ADAs in 24 samples. Samples negative for ADAs with Theradiag, but ADA-positive in both the in-house and Immundiagnostik assays, were positive for IFX or IgG4 ADAs. In spiking experiments, a low concentration of exogenous IFX (5 mu g/ml) hampered ADA detection with Theradiag in sera samples with ADA levels of between 3 and 10 mu g/ml. In the Immundiagnostik assay detection interference was only observed at concentrations of exogenous IFX higher than 30 mu g/ml. However, in samples with high levels of ADAs (> 25 mu g/ml) interference was only observed at IFX concentrations higher than 100 mu g/ml in all three assays. Binary (IFX/ADA) stratification of the results showed that IFX+/ADA and IFX-/ADAs + were less influenced by the assay results than the double-positive (IFX+/ADAs+) and double-negative (IFX-/ADAs-) combination.Conclusions: All three methodologies are equally suitable for measuring IFX levels. However, erroneous therapeutic decisions may occur when patients show double-negative (IFX-/ADAs) or double-positive (IFX+/ADAs+) status, since agreement between assays is significantly lower in these circumstances. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-07 2016-07-01T00:00:00Z 2017-04-07T15:55:46Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.1/9216 |
url |
http://hdl.handle.net/10400.1/9216 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1756-283X 10.1177/1756283X16658223 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
SAGE Publications |
publisher.none.fl_str_mv |
SAGE Publications |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833598730802036736 |