Determination of 2,4,6-trichloroanisole by cyclic voltammetry
| Autor(a) principal: | |
|---|---|
| Data de Publicação: | 2012 |
| Outros Autores: | , , , |
| Idioma: | eng |
| Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Texto Completo: | http://hdl.handle.net/10198/10607 |
Resumo: | The electrochemical reduction of 2,4,6-trichloroanisole (TCA), which is a chlorinated arene with electron-donating substituents, was evaluated by cyclic voltammetry (CV). TCA is a major concern for the winery industry since it is related with “cork taint”, a wine defect. The results obtained in this work showed that CV could be used to detect and quantify TCA in preparative standard solutions. Linear relationships could be set between the current amplitude and TCA concentration (R > 0.999), being the detection (LOD) and quantification (LOQ) limits of 0.8 and 2.0 ppm, respectively. Although, these preliminary limits are higher than the human sensory threshold (around 5 ppt in wine), the simplicity and low-cost of the methodology confer this study a possible role in the development of more efficient, less expensive processes for TCA detection in the industry. |
| id |
RCAP_c83aae91852f11f24c9e044f0791d65d |
|---|---|
| oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/10607 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Determination of 2,4,6-trichloroanisole by cyclic voltammetryThe electrochemical reduction of 2,4,6-trichloroanisole (TCA), which is a chlorinated arene with electron-donating substituents, was evaluated by cyclic voltammetry (CV). TCA is a major concern for the winery industry since it is related with “cork taint”, a wine defect. The results obtained in this work showed that CV could be used to detect and quantify TCA in preparative standard solutions. Linear relationships could be set between the current amplitude and TCA concentration (R > 0.999), being the detection (LOD) and quantification (LOQ) limits of 0.8 and 2.0 ppm, respectively. Although, these preliminary limits are higher than the human sensory threshold (around 5 ppt in wine), the simplicity and low-cost of the methodology confer this study a possible role in the development of more efficient, less expensive processes for TCA detection in the industry.Biblioteca Digital do IPBFreitas, PatríciaDias, L.G.Peres, António M.Castro, Luís M.Veloso, Ana C.A.2014-09-25T16:12:27Z20122012-01-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10198/10607engFreitas, Patrícia; Dias, Luís G.; Peres, António M.; Castro, Luís M.; Veloso, Ana C.A. (2012). Determination of 2,4,6-trichloroanisole by cyclic voltammetry. In 26th European Conference on Solid-State Transducers, Eurosensor 2012. Kraków, Polandinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-25T12:01:49Zoai:bibliotecadigital.ipb.pt:10198/10607Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T11:26:50.123233Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| title |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| spellingShingle |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry Freitas, Patrícia |
| title_short |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| title_full |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| title_fullStr |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| title_full_unstemmed |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| title_sort |
Determination of 2,4,6-trichloroanisole by cyclic voltammetry |
| author |
Freitas, Patrícia |
| author_facet |
Freitas, Patrícia Dias, L.G. Peres, António M. Castro, Luís M. Veloso, Ana C.A. |
| author_role |
author |
| author2 |
Dias, L.G. Peres, António M. Castro, Luís M. Veloso, Ana C.A. |
| author2_role |
author author author author |
| dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
| dc.contributor.author.fl_str_mv |
Freitas, Patrícia Dias, L.G. Peres, António M. Castro, Luís M. Veloso, Ana C.A. |
| description |
The electrochemical reduction of 2,4,6-trichloroanisole (TCA), which is a chlorinated arene with electron-donating substituents, was evaluated by cyclic voltammetry (CV). TCA is a major concern for the winery industry since it is related with “cork taint”, a wine defect. The results obtained in this work showed that CV could be used to detect and quantify TCA in preparative standard solutions. Linear relationships could be set between the current amplitude and TCA concentration (R > 0.999), being the detection (LOD) and quantification (LOQ) limits of 0.8 and 2.0 ppm, respectively. Although, these preliminary limits are higher than the human sensory threshold (around 5 ppt in wine), the simplicity and low-cost of the methodology confer this study a possible role in the development of more efficient, less expensive processes for TCA detection in the industry. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012 2012-01-01T00:00:00Z 2014-09-25T16:12:27Z |
| dc.type.driver.fl_str_mv |
conference object |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/10607 |
| url |
http://hdl.handle.net/10198/10607 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
Freitas, Patrícia; Dias, Luís G.; Peres, António M.; Castro, Luís M.; Veloso, Ana C.A. (2012). Determination of 2,4,6-trichloroanisole by cyclic voltammetry. In 26th European Conference on Solid-State Transducers, Eurosensor 2012. Kraków, Poland |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833591914205544448 |